Literature DB >> 3400908

Signal processing strategies for enhancement of signal-to-noise ratio of thermodilution measurements.

R W Johnson1, R A Normann.   

Abstract

Thermodilution measurements of clinically important cardiac parameters, such as cardiac output and stroke volume, are subject to many sources of error. The temperature fluctuations (thermal noise) normally found in the pulmonary artery constitute one of these sources of errors. To improve the signal-to-noise ratio of thermodilution flow measurements rather than increase the signal level, we investigated four signal processing strategies designed to reduce the thermal noise power. We applied the noise reduction strategies to thermal noise data, containing simulated thermodilution curves, obtained in a mock circulatory loop. We compared the accuracy and reproducibility of the curve area estimates produced by the algorithms to the area estimates obtained by numerical integration of the thermal signal. Our results show that a bandpass (BP) integration technique combined with a noise canceler can improve thermodilution curve area estimate reproducibility and accuracy. The BP integration technique improved the reproducibility of cardiac output measurements by roughly 16 dB and is directly applicable to most thermodilution hardware currently in use. The more accurate noise cancelers, combined with the BP integration technique, provided correspondingly improved signal-to-noise ratios, with the improvement ranging up to 50 dB.

Entities:  

Mesh:

Year:  1988        PMID: 3400908     DOI: 10.1007/bf02368003

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  12 in total

1.  Temperature variations in the venous system of dogs.

Authors:  S AFONSO; J F HERRICK; W B YOUMANS; G G ROWE; C W CRUMPTON
Journal:  Am J Physiol       Date:  1962-08

2.  Mathematical and mechanical modeling of heat transport through the heart.

Authors:  R W Johnson; R A Normann
Journal:  Ann Biomed Eng       Date:  1987       Impact factor: 3.934

Review 3.  Measurement of blood flow by thermodilution.

Authors:  W Ganz; H J Swan
Journal:  Am J Cardiol       Date:  1972-02       Impact factor: 2.778

4.  Limitations of thermal dilution curves for cardiac output determinations.

Authors:  H U Wessel; M H Paul; G W James; A R Grahn
Journal:  J Appl Physiol       Date:  1971-05       Impact factor: 3.531

5.  Measurement of cardiac output by thermal-dilution and direct Fick methods in dogs.

Authors:  H H Khalil; T Q Richardson; A C Guyton
Journal:  J Appl Physiol       Date:  1966-05       Impact factor: 3.531

6.  Practical considerations for the use of a pulmonary artery thermistor catheter.

Authors:  M Woods; R N Scott; A H Harken
Journal:  Surgery       Date:  1976-04       Impact factor: 3.982

Review 7.  Technical aspects of the thermodilution method for measuring cardiac output.

Authors:  M S Riedinger; F G Shellock
Journal:  Heart Lung       Date:  1984-05       Impact factor: 2.210

8.  Continuous thermal measurement of cardiac output.

Authors:  J H Philip; M C Long; M D Quinn; R S Newbower
Journal:  IEEE Trans Biomed Eng       Date:  1984-05       Impact factor: 4.538

9.  Multiple cardiac output measurements in man. Evaluation of a new closed-system thermodilution method.

Authors:  J J Stawicki; F D Holford; E L Michelson; M E Josephson
Journal:  Chest       Date:  1979-08       Impact factor: 9.410

10.  Cardiac output by thermodilution technique. Effect of injectate's volume and temperature on accuracy and reproducibility in the critically Ill patient.

Authors:  U Elkayam; R Berkley; S Azen; L Weber; B Geva; W L Henry
Journal:  Chest       Date:  1983-10       Impact factor: 9.410

View more
  6 in total

1.  Central venous blood temperature fluctuations and thermodilution signal processing in dogs.

Authors:  R W Johnson; R A Normann
Journal:  Ann Biomed Eng       Date:  1989       Impact factor: 3.934

2.  Mathematical and mechanical modeling of heat transport through the heart.

Authors:  R W Johnson; R A Normann
Journal:  Ann Biomed Eng       Date:  1987       Impact factor: 3.934

3.  A continuous cardiac output computer based on thermodilution principles.

Authors:  R A Normann; R W Johnson; J E Messinger; B Sohrab
Journal:  Ann Biomed Eng       Date:  1989       Impact factor: 3.934

4.  Reliability of thermodilution derived cardiac output with different operator characteristics.

Authors:  Scott C McKenzie; Kimble Dunster; Wandy Chan; Martin R Brown; David G Platts; George Javorsky; Chris Anstey; Shaun D Gregory
Journal:  J Clin Monit Comput       Date:  2017-03-09       Impact factor: 2.502

5.  In vitro validation of a right ventricular thermodilution ejection fraction system.

Authors:  R Mukherjee; F G Spinale; A F von Recum; F A Crawford
Journal:  Ann Biomed Eng       Date:  1991       Impact factor: 3.934

6.  Non-invasive measurement of cardiac output: whole-body impedance cardiography in simultaneous comparison with thermodilution and direct oxygen Fick methods.

Authors:  T Kööbi; S Kaukinen; T Ahola; V M Turjanmaa
Journal:  Intensive Care Med       Date:  1997-11       Impact factor: 17.440

  6 in total