Literature DB >> 34001941

Dosimetry with gafchromic films based on a new micro-opto-electro-mechanical system.

C Guardiola1, A Márquez2, M C Jiménez-Ramos3, J García López3,4, A Baratto-Roldán3,4, X Muñoz-Berbel2.   

Abstract

This work presents the first tests performed with radiochromic films and a new Micro‒Opto‒Electro-Mechanical system (MOEMS) for in situ dosimetry evaluation in radiotherapy in real time. We present a new device and methodology that overcomes the traditional limitation of time-delay in radiochromic film analysis by turning a passive detector into an active sensor. The proposed system consists mainly of an optical sensor based on light emitting diodes and photodetectors controlled by both customized electronic circuit and graphical user interface, which enables optical measurements directly. We show the first trials performed in a low‒energy proton cyclotron with this MOEMS by using gafchromic EBT3 films. Results show the feasibility of using this system for in situ dose evaluations. Further adaptation is ongoing to develop a full real‒time active detector by integrating MOEM multi‒arrays and films in flexible printed circuits. Hence, we point to improve the clinical application of radiochromic films with the aim to optimize radiotherapy treatment verifications.

Entities:  

Year:  2021        PMID: 34001941     DOI: 10.1038/s41598-021-89602-9

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.379


  18 in total

1.  Characteristic of EBT-XD and EBT3 radiochromic film dosimetry for photon and proton beams.

Authors:  Suphalak Khachonkham; Ralf Dreindl; Gerd Heilemann; Wolfgang Lechner; Hermann Fuchs; Hugo Palmans; Dietmar Georg; Peter Kuess
Journal:  Phys Med Biol       Date:  2018-03-15       Impact factor: 3.609

2.  Gafchromic EBT film dosimetry in proton beams.

Authors:  Li Zhao; Indra J Das
Journal:  Phys Med Biol       Date:  2010-04-29       Impact factor: 3.609

Review 3.  Radiochromic film dosimetry: past, present, and future.

Authors:  Slobodan Devic
Journal:  Phys Med       Date:  2010-11-02       Impact factor: 2.685

4.  GafChromic(®) EBT3 films for patient specific IMRT QA using a multichannel approach.

Authors:  Livia Marrazzo; Margherita Zani; Stefania Pallotta; Chiara Arilli; Marta Casati; Antonella Compagnucci; Cinzia Talamonti; Marta Bucciolini
Journal:  Phys Med       Date:  2015-10-01       Impact factor: 2.685

5.  Characterization and use of EBT radiochromic film for IMRT dose verification.

Authors:  Omar A Zeidan; Stacy Ann L Stephenson; Sanford L Meeks; Thomas H Wagner; Twyla R Willoughby; Patrick A Kupelian; Katja M Langen
Journal:  Med Phys       Date:  2006-11       Impact factor: 4.071

6.  Comparison of Kodak EDR2 and Gafchromic EBT film for intensity-modulated radiation therapy dose distribution verification.

Authors:  A Sankar; Komanduri M Ayyangar; R Mothilal Nehru; P G Gopalakrishna Kurup; V Murali; Charles A Enke; J Velmurugan
Journal:  Med Dosim       Date:  2006       Impact factor: 1.482

7.  LET dependence of GafChromic films and an ion chamber in low-energy proton dosimetry.

Authors:  Daniel Kirby; Stuart Green; Hugo Palmans; Richard Hugtenburg; Cecile Wojnecki; David Parker
Journal:  Phys Med Biol       Date:  2009-12-17       Impact factor: 3.609

Review 8.  Review on the characteristics of radiation detectors for dosimetry and imaging.

Authors:  Joao Seco; Ben Clasie; Mike Partridge
Journal:  Phys Med Biol       Date:  2014-09-17       Impact factor: 3.609

9.  Dosimetric characterization and use of GAFCHROMIC EBT3 film for IMRT dose verification.

Authors:  Valeria Casanova Borca; Massimo Pasquino; Giuliana Russo; Pierangelo Grosso; Domenico Cante; Piera Sciacero; Giuseppe Girelli; Maria Rosa La Porta; Santi Tofani
Journal:  J Appl Clin Med Phys       Date:  2013-03-04       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.