Comparison of Kodak EDR2 and Gafchromic EBT film for intensity-modulated radiation therapy dose distribution verification.

A Sankar1, Komanduri M Ayyangar, R Mothilal Nehru, P G Gopalakrishna Kurup, V Murali, Charles A Enke, J Velmurugan.   

Abstract

The quantitative dose validation of intensity-modulated radiation therapy (IMRT) plans require 2-dimensional (2D) high-resolution dosimetry systems with uniform response over its sensitive region. The present work deals with clinical use of commercially available self-developing Radio Chromic Film, Gafchromic EBT film, for IMRT dose verification. Dose response curves were generated for the films using a VXR-16 film scanner. The results obtained with EBT films were compared with the results of Kodak extended dose range 2 (EDR2) films. The EBT film had a linear response between the dose range of 0 to 600 cGy. The dose-related characteristics of the EBT film, such as post irradiation color growth with time, film uniformity, and effect of scanning orientation, were studied. There was up to 8.6% increase in the color density between 2 to 40 hours after irradiation. There was a considerable variation, up to 8.5%, in the film uniformity over its sensitive region. The quantitative differences between calculated and measured dose distributions were analyzed using DTA and Gamma index with the tolerance of 3% dose difference and 3-mm distance agreement. The EDR2 films showed consistent results with the calculated dose distributions, whereas the results obtained using EBT were inconsistent. The variation in the film uniformity limits the use of EBT film for conventional large-field IMRT verification. For IMRT of smaller field sizes (4.5 x 4.5 cm), the results obtained with EBT were comparable with results of EDR2 films.

Entities:  

Mesh:

Year:  2006        PMID: 17134667     DOI: 10.1016/j.meddos.2006.06.001

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  11 in total

1.  Wax boluses and accuracy of EBT and RTQA radiochromic film detectors in radiotherapy with the JINR Phasotron proton beam.

Authors:  Dorota Maria Borowicz; Julian Malicki; Gennady Mytsin; Konstantin Shipulin
Journal:  Rep Pract Oncol Radiother       Date:  2013-07-02

2.  Optimal sensitometric curves of Kodak EDR2 film for dynamic intensity modulated radiation therapy verification.

Authors:  S Suriyapee; N Pitaxtarnin; S Oonsiri; C Jumpangern; I Israngkul Na Ayuthaya
Journal:  Biomed Imaging Interv J       Date:  2008-01-01

3.  Experimental dosimetry of EDR2 films in scanning carbon-ion irradiation.

Authors:  Weiwei Wang; Yu Deng; Zhijie Huang
Journal:  J Appl Clin Med Phys       Date:  2022-05-20       Impact factor: 2.243

4.  Dose distribution comparison in volumetric-modulated arc therapy plans for head and neck cancers with and without an external body contour extended technique.

Authors:  Yoshihiro Tanaka; Hajime Monzen; Kenji Matsumoto; Shinichiro Inomata; Toshiaki Fuse
Journal:  Rep Pract Oncol Radiother       Date:  2019-11-02

5.  Dosimetry with gafchromic films based on a new micro-opto-electro-mechanical system.

Authors:  C Guardiola; A Márquez; M C Jiménez-Ramos; J García López; A Baratto-Roldán; X Muñoz-Berbel
Journal:  Sci Rep       Date:  2021-05-17       Impact factor: 4.379

6.  Experimental and Simulation Analysis of Radiation of the Beta Emitting Sources in a Magnetic Field.

Authors:  Berrin Çavuşoğlu; Selda Sucu; Hatice Durak; Kadir Akgüngör; Hakan Epik; Türkan Ertay
Journal:  Mol Imaging Radionucl Ther       Date:  2017-06-01

7.  Evaluation of Targeted Image-Guided Radiation Therapy Treatment Planning System by Use of American Association of Physicists in Medicine Task Group-119 Test Cases.

Authors:  Mohsen Saeb; Daryoush Shahbazi-Gahrouei; Shahram Monadi
Journal:  J Med Signals Sens       Date:  2018 Apr-Jun

8.  Comparison of EBT and EBT3 RadioChromic Film Usage in Parotid Cancer Radiotherapy.

Authors:  M T Bahreyni Toossi; F Khorshidi; M Ghorbani; N Mohamadian; D Davenport
Journal:  J Biomed Phys Eng       Date:  2016-03-01

9.  Radiographic film dosimetry for IMRT fields in the nearsurface buildup region.

Authors:  Peter L Roberson; Jean M Moran; Ravi Kulasekere
Journal:  J Appl Clin Med Phys       Date:  2008-10-24       Impact factor: 2.102

10.  Evaluation of the uncertainty in an EBT3 film dosimetry system utilizing net optical density.

Authors:  Elsa Y León Marroquin; José A Herrera González; Miguel A Camacho López; José E Villarreal Barajas; Olivia A García-Garduño
Journal:  J Appl Clin Med Phys       Date:  2016-09-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.