Literature DB >> 33902155

Free-breathing abdominal T1 mapping using an optimized MR fingerprinting sequence.

Max H C van Riel1,2,3, Zidan Yu2,3,4, Shota Hodono2,3,4,5, Ding Xia2,3, Hersh Chandarana2,3, Koji Fujimoto6,7, Martijn A Cloos2,3,4,5.   

Abstract

In this work, we propose a free-breathing magnetic resonance fingerprinting (MRF) method that can be used to obtain B1 + -robust quantitative T1 maps of the abdomen in a clinically acceptable time. A three-dimensional MRF sequence with a radial stack-of-stars trajectory was implemented, and its k-space acquisition ordering was adjusted to improve motion-robustness in the context of MRF. The flip angle pattern was optimized using the Cramér-Rao Lower Bound, and the encoding efficiency of sequences with 300, 600, 900 and 1800 flip angles was evaluated. To validate the sequence, a movable multicompartment phantom was developed. Reference multiparametric maps were acquired under stationary conditions using a previously validated MRF method. Periodic motion of the phantom was used to investigate the motion-robustness of the proposed sequence. The best performing sequence length (600 flip angles) was used to image the abdomen during a free-breathing volunteer scan. When using a series of 600 or more flip angles, the estimated T1 values in the stationary phantom showed good agreement with the reference scan. Phantom experiments revealed that motion-related artifacts can appear in the quantitative maps and confirmed that a motion-robust k-space ordering is essential. The in vivo scan demonstrated that the proposed sequence can produce clean parameter maps while the subject breathes freely. Using this sequence, it is possible to generate B1 + -robust quantitative maps of T1 and B1 + next to M0 -weighted images under free-breathing conditions at a clinically usable resolution within 5 min.
© 2021 John Wiley & Sons, Ltd.

Entities:  

Keywords:  abdominal imaging, Cramér-Rao lower bound, magnetic resonance fingerprinting, quantitative imaging, respiratory motion

Mesh:

Year:  2021        PMID: 33902155      PMCID: PMC8218311          DOI: 10.1002/nbm.4531

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  37 in total

1.  Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state.

Authors:  Sean C L Deoni; Brian K Rutt; Terry M Peters
Journal:  Magn Reson Med       Date:  2003-03       Impact factor: 4.668

2.  Low rank alternating direction method of multipliers reconstruction for MR fingerprinting.

Authors:  Jakob Assländer; Martijn A Cloos; Florian Knoll; Daniel K Sodickson; Jürgen Hennig; Riccardo Lattanzi
Journal:  Magn Reson Med       Date:  2017-03-05       Impact factor: 4.668

3.  Image reconstruction algorithm for motion insensitive MR Fingerprinting (MRF): MORF.

Authors:  Bhairav Bipin Mehta; Dan Ma; Eric Yann Pierre; Yun Jiang; Simone Coppo; Mark Alan Griswold
Journal:  Magn Reson Med       Date:  2018-05-06       Impact factor: 4.668

4.  Central brightening due to constructive interference with, without, and despite dielectric resonance.

Authors:  Christopher M Collins; Wanzhan Liu; Weston Schreiber; Qing X Yang; Michael B Smith
Journal:  J Magn Reson Imaging       Date:  2005-02       Impact factor: 4.813

Review 5.  Quantitative relaxometry of the brain.

Authors:  Sean C L Deoni
Journal:  Top Magn Reson Imaging       Date:  2010-04

6.  Optimized quantification of spin relaxation times in the hybrid state.

Authors:  Jakob Assländer; Riccardo Lattanzi; Daniel K Sodickson; Martijn A Cloos
Journal:  Magn Reson Med       Date:  2019-06-12       Impact factor: 4.668

7.  Rapid B1+ mapping using a preconditioning RF pulse with TurboFLASH readout.

Authors:  Sohae Chung; Daniel Kim; Elodie Breton; Leon Axel
Journal:  Magn Reson Med       Date:  2010-08       Impact factor: 4.668

8.  MR Fingerprinting for Rapid Quantitative Abdominal Imaging.

Authors:  Yong Chen; Yun Jiang; Shivani Pahwa; Dan Ma; Lan Lu; Michael D Twieg; Katherine L Wright; Nicole Seiberlich; Mark A Griswold; Vikas Gulani
Journal:  Radiology       Date:  2016-01-21       Impact factor: 11.105

9.  Joint system relaxometry (JSR) and Crámer-Rao lower bound optimization of sequence parameters: A framework for enhanced precision of DESPOT T1 and T2 estimation.

Authors:  Rui Pedro A G Teixeira; Shaihan J Malik; Joseph V Hajnal
Journal:  Magn Reson Med       Date:  2017-03-16       Impact factor: 4.668

10.  Liver MR relaxometry at 3T - segmental normal T1 and T2* values in patients without focal or diffuse liver disease and in patients with increased liver fat and elevated liver stiffness.

Authors:  V C Obmann; N Mertineit; C Marx; A Berzigotti; L Ebner; J T Heverhagen; A Christe; A T Huber
Journal:  Sci Rep       Date:  2019-05-30       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.