Literature DB >> 33828875

Effect of Low-Level Laser Therapy on Peri-Miniscrew Fluid Prostaglandin E2 and Substance P Levels: A Controlled Clinical Trial.

Özer Alkan1, Yeşim Kaya2, Esra Yüksek2, Ahmet Ufuk Kömüroglu3.   

Abstract

OBJECTIVE: This study aims to evaluate the effect of low-level laser therapy on peri-miniscrew fluid prostaglandin E2 (PGE2) and substance P (SP) levels during orthodontic treatment.
METHODS: A total of 15 individuals were included in this study. Miniscrews were inserted to the inter-radicular region of the maxillary right and left second premolar and the first molar teeth, and diode lasers were randomly applied to the right or left side. Irradiation was performed at 940 nm wavelength using a gallium-aluminum-arsenide diode laser with 100 mW power output, 0.125 cm2 spectral area, 8 J/cm2 energy density, and 10 seconds of exposure time. Peri-miniscrew fluid samples were collected on the 1st, 3rd, and 7th days, and PGE2 and SP levels were assessed. For statistical comparison, two-way (factors) analysis of variance with repeated measurements on one-factor levels was used at statistical significance (p) of <0.05.
RESULTS: PGE2 levels on the 1st, 3rd, and 7th days were 160.64±10.05, 135.17±37.18, and 98.57±22.94, respectively, in the control group and 150.75±9.08, 87.17±40.67, and 78.10±16.50, respectively, in the laser group. SP levels on the 1st, 3rd, and 7th days were 79.90±12.05, 64.61±10.05, and 70.05±9.10, respectively, in the control group and 76.32±11.39, 60.25±9.08, and 65.71±5.59, respectively, in the laser group. The differences in PGE2 and SP levels between the laser and control groups were not statistically significant at all time intervals.
CONCLUSION: Low-level laser therapy cannot be recommended as a clinical adjunct therapy to reduce inflammation and pain around the miniscrews. © Copyright 2021 by Turkish Orthodontic Society.

Entities:  

Keywords:  Inflamation; PGE2; SP; miniscrew; pain

Year:  2021        PMID: 33828875      PMCID: PMC7990274          DOI: 10.5152/TurkJOrthod.2021.20049

Source DB:  PubMed          Journal:  Turk J Orthod        ISSN: 2148-9505


  25 in total

1.  The effect of low-level laser therapy as an adjunct to non-surgical periodontal treatment.

Authors:  Gokce Aykol; Ulku Baser; Ilay Maden; Zafer Kazak; Utku Onan; Sevda Tanrikulu-Kucuk; Evin Ademoglu; Halim Issever; Funda Yalcin
Journal:  J Periodontol       Date:  2010-10-08       Impact factor: 6.993

2.  Advances and perspectives on tissue repair and healing.

Authors:  Antonio L B Pinheiro
Journal:  Photomed Laser Surg       Date:  2009-12       Impact factor: 2.796

3.  The effect of 810-nm low-level laser therapy on pain caused by orthodontic elastomeric separators.

Authors:  Ladan Eslamian; Ali Borzabadi-Farahani; Aidin Hassanzadeh-Azhiri; Mohammad R Badiee; Reza Fekrazad
Journal:  Lasers Med Sci       Date:  2013-01-20       Impact factor: 3.161

4.  Effects of Low-Level Laser Therapy in Orthodontic Patients on Immediate Inflammatory Response After Mini-Implants Insertion: A Preliminary Report.

Authors:  Mario S Yanaguizawa; Selly S Suzuki; Elizabeth F Martinez; Hideo Suzuki; Maria Cristina J Pelegrin; Aguinaldo S Garcez
Journal:  Photomed Laser Surg       Date:  2016-11-03       Impact factor: 2.796

5.  The relationship between concentrations of proinflammatory cytokines within gingiva and the adjacent sulcular depth.

Authors:  J M McGee; M A Tucci; T P Edmundson; C L Serio; R B Johnson
Journal:  J Periodontol       Date:  1998-08       Impact factor: 6.993

6.  Production of inflammatory mediators and cytokines by human gingival fibroblasts following bacterial challenge.

Authors:  A I Dongari-Bagtzoglou; J L Ebersole
Journal:  J Periodontal Res       Date:  1996-02       Impact factor: 4.419

7.  Evaluation of Low Level Laser Therapy on Pain Perception Following Orthodontic Elastomeric Separation: A Randomized Controlled Trial.

Authors:  Mai M E Almallah; Wael H Almahdi; Mohammad Y Hajeer
Journal:  J Clin Diagn Res       Date:  2016-11-01

8.  "Safe zones": a guide for miniscrew positioning in the maxillary and mandibular arch.

Authors:  Paola Maria Poggio; Cristina Incorvati; Stefano Velo; Aldo Carano
Journal:  Angle Orthod       Date:  2006-03       Impact factor: 2.079

9.  Chondroitin sulphate (WF6 epitope) levels in peri-miniscrew implant crevicular fluid during orthodontic loading.

Authors:  Imjai Intachai; Suttichai Krisanaprakornkit; Prachya Kongtawelert; Siriwan Ong-chai; Boonsiva Buranastidporn; Eduardo Yugo Suzuki; Dhirawat Jotikasthira
Journal:  Eur J Orthod       Date:  2009-09-13       Impact factor: 3.075

10.  Five-year experience with orthodontic miniscrew implants: a retrospective investigation of factors influencing success rates.

Authors:  Joanna Antoszewska; Moschos A Papadopoulos; Hyo-Sang Park; Björn Ludwig
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-08       Impact factor: 2.650

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.