Literature DB >> 19752017

Chondroitin sulphate (WF6 epitope) levels in peri-miniscrew implant crevicular fluid during orthodontic loading.

Imjai Intachai1, Suttichai Krisanaprakornkit, Prachya Kongtawelert, Siriwan Ong-chai, Boonsiva Buranastidporn, Eduardo Yugo Suzuki, Dhirawat Jotikasthira.   

Abstract

The aim of this study was to monitor changes in chondroitin sulphate (CS; WF6 epitope) levels in peri-miniscrew implant crevicular fluid (PMICF) during orthodontic loading. Ten patients (seven males and three females; aged 22.0 +/- 3.4 years), who required orthodontic treatment with extraction of all four premolar teeth, participated in the study. Twenty miniscrew implants (used as orthodontic anchorage) were placed, two in each patient, buccally and bilaterally in the alveolar bone between the roots of the maxillary posterior teeth. Sentalloy closed-coil springs (50 g) were used to load the miniscrew implants and to move the maxillary canines distally. During the unloaded period, PMICF samples were collected on days 1, 3, 5, and 7 after miniscrew implant placement and on days 14, 21, 28, and 35 during the loaded period. Clinical mobility assessments of the miniscrew implants were recorded at each visit. The competitive enzyme-linked immunosorbent assay with monoclonal antibody WF6 was used to detect CS (WF6 epitope) levels in the PMICF samples. The differences between the CS (WF6 epitope) levels during the unloaded and loaded periods were determined by a Mann-Whitney U-test. During the loaded period, two miniscrew implants were considered to have failed. The CS (WF6 epitope) levels during the unloaded period ranged from 0.00 to 758.03 ng/ml and those during the loaded period from 0.00 to 1025.11 ng/ml. Medians of CS (WF6 epitope) levels, around 'immobile' miniscrew implants, between the unloaded and loaded periods were not significantly different (P = 0.07). CS (WF6 epitope) levels in PMICF can be detected and may be used as biomarkers for assessing alveolar bone remodelling around miniscrew implants during orthodontic loading.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19752017     DOI: 10.1093/ejo/cjp056

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  7 in total

1.  Comparison of BALP, CTX-I, and IL-4 levels around miniscrew implants during orthodontic tooth movement between two different amounts of force.

Authors:  Mine Gecgelen Cesur; V Ozgen Ozturk; Beral Afacan; F Burcu Sirin; Afra Alkan; Torun Ozer
Journal:  Angle Orthod       Date:  2019-02-07       Impact factor: 2.079

2.  Levels of TGF-β1 in peri-miniscrew implant crevicular fluid.

Authors:  Avinash Kaur; Om Prakash Kharbanda; Moganty R Rajeswari; Dinesh Kalyanasundaram
Journal:  J Oral Biol Craniofac Res       Date:  2020-03-06

3.  Effect of Low-Level Laser Therapy on Peri-Miniscrew Fluid Prostaglandin E2 and Substance P Levels: A Controlled Clinical Trial.

Authors:  Özer Alkan; Yeşim Kaya; Esra Yüksek; Ahmet Ufuk Kömüroglu
Journal:  Turk J Orthod       Date:  2021-03-01

Review 4.  A review of biomarkers in peri-miniscrew implant crevicular fluid (PMICF).

Authors:  Avinash Kaur; Om P Kharbanda; Priyanka Kapoor; Dinesh Kalyanasundaram
Journal:  Prog Orthod       Date:  2017-11-27       Impact factor: 2.750

5.  Biochemical and Clinical Assessments of Segmental Maxillary Posterior Tooth Intrusion.

Authors:  Jintana Tasanapanont; Tanapan Wattanachai; Janya Apisariyakul; Peraphan Pothacharoen; Siriwan Ongchai; Prachya Kongtawelert; Marit Midtbø; Dhirawat Jotikasthira
Journal:  Int J Dent       Date:  2017-02-22

6.  A study of interleukin 1β levels in peri-miniscrew crevicular fluid (PMCF).

Authors:  Nitika Monga; Sushma Chaurasia; Om Prakash Kharbanda; Ritu Duggal; Moganty Raja Rajeswari
Journal:  Prog Orthod       Date:  2014-04-01       Impact factor: 2.750

7.  Comparisons between two biochemical markers in evaluating periodontal disease severity: a cross-sectional study.

Authors:  Sakornrat Khongkhunthian; Prachya Kongtawelert; Siriwan Ongchai; Peraphan Pothacharoen; Thanapat Sastraruji; Dhirawat Jotikasthira; Suttichai Krisanaprakornkit
Journal:  BMC Oral Health       Date:  2014-08-30       Impact factor: 2.757

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.