Literature DB >> 33801960

Primary Evaluation of Shape Recovery of Orthodontic Aligners Fabricated from Shape Memory Polymer (A Typodont Study).

Tarek M Elshazly1, Ludger Keilig1, Yasmine Alkabani2, Ahmed Ghoneima3, Moosa Abuzayda4, Sameh Talaat1,5, Christoph P Bourauel1.   

Abstract

As an innovative approach to overcome the rate-limiting staging of conventional aligners, using shape memory polymers (SMPs) as aligners' materials was investigated in this in vitro study. The ability of SMPs to shape recover and consequently move tooth, upon appropriate stimuli, was evaluated on a typodont model before clinical application. The study design was to achieve 1.9 mm correction movement of an upper central incisor by one aligner after multiple steps/activation. A custom-made aligned typodont model with a movable upper central incisor was scanned. Using an orthodontic software and a 3D printer, resin-models were generated. Seven aligners of ClearX sheets (SMPs) were fabricated by thermoforming on the resin aligned model. Each aligner was tested for repositioning of the central incisor in the typodont model. The model was scanned after each step and the corrective movement was measured through the superimposition of scans. Results showed that the total correction efficiency of the SMPs' aligner was ≈93% (1.76 mm). The corrective movement was 0.94 ± 0.04 mm after the reforming step, 0.66 ± 0.07 mm after the first activation step, and 0.15 ± 0.10 mm after the second activation step. It was concluded that aligners made of SMPs could have a promising future-use in orthodontic aesthetic treatment.

Entities:  

Keywords:  3D printers; clear aligners; dentistry; digital workflow; orthodontic appliance; orthodontics; smart polymers; typodont

Year:  2021        PMID: 33801960      PMCID: PMC7998399          DOI: 10.3390/dj9030031

Source DB:  PubMed          Journal:  Dent J (Basel)        ISSN: 2304-6767


  19 in total

1.  Simulation of orthodontic tooth movements. A comparison of numerical models.

Authors:  C Bourauel; D Freudenreich; D Vollmer; D Kobe; D Drescher; A Jäger
Journal:  J Orofac Orthop       Date:  1999       Impact factor: 1.938

2.  Clinical limitations of Invisalign.

Authors:  Xiem Phan; Paul H Ling
Journal:  J Can Dent Assoc       Date:  2007-04       Impact factor: 1.316

Review 3.  Efficiency, effectiveness and treatment stability of clear aligners: A systematic review and meta-analysis.

Authors:  M Zheng; R Liu; Z Ni; Z Yu
Journal:  Orthod Craniofac Res       Date:  2017-05-26       Impact factor: 1.826

4.  Forces and moments delivered by novel, thinner PET-G aligners during labiopalatal bodily movement of a maxillary central incisor: An in vitro study.

Authors:  Fayez Elkholy; Falko Schmidt; Rudolf Jäger; Bernd G Lapatki
Journal:  Angle Orthod       Date:  2016-05-25       Impact factor: 2.079

5.  A comparative study of two different clear aligner systems.

Authors:  Federica Ercoli; Michele Tepedino; Vincenzo Parziale; Cesare Luzi
Journal:  Prog Orthod       Date:  2014-05-02       Impact factor: 2.750

6.  Application of shape memory polyurethane in orthodontic.

Authors:  Yong Chae Jung; Jae Whan Cho
Journal:  J Mater Sci Mater Med       Date:  2008-07-24       Impact factor: 3.896

7.  Forces and moments generated by removable thermoplastic aligners: incisor torque, premolar derotation, and molar distalization.

Authors:  Mareike Simon; Ludger Keilig; Jörg Schwarze; Britta A Jung; Christoph Bourauel
Journal:  Am J Orthod Dentofacial Orthop       Date:  2014-06       Impact factor: 2.650

Review 8.  Shape-memory polymers.

Authors:  Andreas Lendlein; Steffen Kelch
Journal:  Angew Chem Int Ed Engl       Date:  2002-06-17       Impact factor: 15.336

9.  Treatment outcome and efficacy of an aligner technique--regarding incisor torque, premolar derotation and molar distalization.

Authors:  Mareike Simon; Ludger Keilig; Jörg Schwarze; Britta A Jung; Christoph Bourauel
Journal:  BMC Oral Health       Date:  2014-06-11       Impact factor: 2.757

Review 10.  Shape-Memory Polymers in Dentistry: Systematic Review and Patent Landscape Report.

Authors:  Alessandro Bruni; Francesca Giulia Serra; Andrea Deregibus; Tommaso Castroflorio
Journal:  Materials (Basel)       Date:  2019-07-10       Impact factor: 3.623

View more
  4 in total

1.  Biomechanical Efficacy and Effectiveness of Orthodontic Treatment with Transparent Aligners in Mild Crowding Dentition-A Finite Element Analysis.

Authors:  Jeong-Hee Seo; Min-Seok Kim; Jeong-Hyeon Lee; Emmanuel Eghan-Acquah; Yong-Hoon Jeong; Mi-Hee Hong; Bongju Kim; Sung-Jae Lee
Journal:  Materials (Basel)       Date:  2022-04-26       Impact factor: 3.748

2.  The Effect of Symmetric and Asymmetric Loading of Frontal Segment with Two Curved Cantilevers: An In Vitro Study.

Authors:  Malgorzata Bilinska; Michel Dalstra
Journal:  Dent J (Basel)       Date:  2022-03-29

3.  Force Systems Produced by Different Cantilever Configurations during Deactivation.

Authors:  Malgorzata Bilinska; Isabel Meret Golliez; Michel Dalstra
Journal:  Materials (Basel)       Date:  2022-07-10       Impact factor: 3.748

4.  Effectiveness and Efficacy of Thermoformed and 3D Printed Aligners in Correcting Malocclusion (Spacing) and Its Impact on Periodontal Oral Health and Oral Microbiome: A Double-Blinded Parallel Randomized Controlled Multicenter Clinical Trial.

Authors:  Shahnawaz Khijmatgar; Margherita Tumedei; Massimo Del Fabbro; Gianluca Martino Tartaglia
Journal:  Microorganisms       Date:  2022-07-19
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.