Literature DB >> 30696087

Corrosion of Metallic Biomaterials: A Review.

Noam Eliaz1.   

Abstract

Metallic biomaterials are used in medical devices in humans more than any other family of materials. The corrosion resistance of an implant material affects its functionality and durability and is a prime factor governing biocompatibility. The fundamental paradigm of metallic biomaterials, except biodegradable metals, has been "the more corrosion resistant, the more biocompatible." The body environment is harsh and raises several challenges with respect to corrosion control. In this invited review paper, the body environment is analysed in detail and the possible effects of the corrosion of different biomaterials on biocompatibility are discussed. Then, the kinetics of corrosion, passivity, its breakdown and regeneration in vivo are conferred. Next, the mostly used metallic biomaterials and their corrosion performance are reviewed. These biomaterials include stainless steels, cobalt-chromium alloys, titanium and its alloys, Nitinol shape memory alloy, dental amalgams, gold, metallic glasses and biodegradable metals. Then, the principles of implant failure, retrieval and failure analysis are highlighted, followed by description of the most common corrosion processes in vivo. Finally, approaches to control the corrosion of metallic biomaterials are highlighted.

Entities:  

Keywords:  biocompatibility; biodegradable metals; biomaterials; body environment; corrosion; failure; metallic glasses; shape memory alloys; stainless steels; titanium alloys

Year:  2019        PMID: 30696087      PMCID: PMC6384782          DOI: 10.3390/ma12030407

Source DB:  PubMed          Journal:  Materials (Basel)        ISSN: 1996-1944            Impact factor:   3.623


  131 in total

1.  Evolution of nanoporosity in dealloying.

Authors:  J Erlebacher; M J Aziz; A Karma; N Dimitrov; K Sieradzki
Journal:  Nature       Date:  2001-03-22       Impact factor: 49.962

Review 2.  Nitinol properties affecting uses in interventional radiology.

Authors:  D J Rabkin; E V Lang; D P Brophy
Journal:  J Vasc Interv Radiol       Date:  2000-03       Impact factor: 3.464

3.  Ferrographic tracking of bacterial transport in the field at the narrow channel focus area, Oyster, VA.

Authors:  W P Johnson; P Zhang; M E Fuller; T D Scheibe; B J Mailloux; T C Onstott; M F Deflaun; S S Hubbard; J Radtke; W P Kovacik; W Holben
Journal:  Environ Sci Technol       Date:  2001-01-01       Impact factor: 9.028

4.  Electrochemical studies on the stability and corrosion resistance of titanium-based implant materials.

Authors:  M Aziz-Kerrzo; K G Conroy; A M Fenelon; S T Farrell; C B Breslin
Journal:  Biomaterials       Date:  2001-06       Impact factor: 12.479

5.  Increased corrosion resistance of stent materials by converting current surface film of polycrystalline oxide into amorphous oxide.

Authors:  C C Shih; S J Lin; K H Chung; Y L Chen; Y Y Su
Journal:  J Biomed Mater Res       Date:  2000-11

6.  Focal osteolysis at the junctions of a modular stainless-steel femoral intramedullary nail.

Authors:  D M Jones; J L Marsh; J V Nepola; J J Jacobs; A K Skipor; R M Urban; J L Gilbert; J A Buckwalter
Journal:  J Bone Joint Surg Am       Date:  2001-04       Impact factor: 5.284

7.  Corrosion of surgical implants.

Authors:  M Traisnel; D le Maguer; H F Hildebrand; A Iost
Journal:  Clin Mater       Date:  1990

8.  Measurement and evaluation of galvanic corrosion between titanium/Ti6A14V implants and dental alloys by electrochemical techniques and auger spectrometry.

Authors:  B Grosgogeat; L Reclaru; M Lissac; F Dalard
Journal:  Biomaterials       Date:  1999-05       Impact factor: 12.479

9.  Detection of rare MCF-7 breast carcinoma cells from mixtures of human peripheral leukocytes by magnetic deposition analysis.

Authors:  B Fang; M Zborowski; L R Moore
Journal:  Cytometry       Date:  1999-08-01

Review 10.  Physico-chemical considerations of titanium as a biomaterial.

Authors:  P Tengvall; I Lundström
Journal:  Clin Mater       Date:  1992
View more
  48 in total

1.  Evolution of metallic cardiovascular stent materials: A comparative study among stainless steel, magnesium and zinc.

Authors:  Jiayin Fu; Yingchao Su; Yi-Xian Qin; Yufeng Zheng; Yadong Wang; Donghui Zhu
Journal:  Biomaterials       Date:  2019-11-21       Impact factor: 12.479

Review 2.  Biomaterials as a Vital Frontier for Stem Cell-Based Tissue Regeneration.

Authors:  Ahmed Nugud; Latifa Alghfeli; Moustafa Elmasry; Ibrahim El-Serafi; Ahmed T El-Serafi
Journal:  Front Cell Dev Biol       Date:  2022-03-24

Review 3.  Engineering Tissues of the Central Nervous System: Interfacing Conductive Biomaterials with Neural Stem/Progenitor Cells.

Authors:  Rebecca D Bierman-Duquette; Gevick Safarians; Joyce Huang; Bushra Rajput; Jessica Y Chen; Ze Zhong Wang; Stephanie K Seidlits
Journal:  Adv Healthc Mater       Date:  2021-12-16       Impact factor: 9.933

Review 4.  Biodegradable Iron and Porous Iron: Mechanical Properties, Degradation Behaviour, Manufacturing Routes and Biomedical Applications.

Authors:  Mariana Salama; Maria Fátima Vaz; Rogério Colaço; Catarina Santos; Maria Carmezim
Journal:  J Funct Biomater       Date:  2022-06-01

Review 5.  Metallic Implants Used in Lumbar Interbody Fusion.

Authors:  Jakub Litak; Michał Szymoniuk; Wojciech Czyżewski; Zofia Hoffman; Joanna Litak; Leon Sakwa; Piotr Kamieniak
Journal:  Materials (Basel)       Date:  2022-05-20       Impact factor: 3.748

6.  Preliminary Proof-of-Concept Testing of Novel Antimicrobial Heat-Conducting "Metallic" Coatings Against Biofouling and Biocorrosion.

Authors:  Di Wang; Timothy D Hall; Tingyue Gu
Journal:  Front Microbiol       Date:  2022-06-30       Impact factor: 6.064

7.  Nano-Scale Surface Modifications to Advance Current Treatment Options for Cervical Degenerative Disc Disease (CDDD).

Authors:  Anne Yau; Ian Sands; Yupeng Chen
Journal:  J Orthop Res Ther       Date:  2019-10-06

8.  Cytocompatibility and Bioactive Ion Release Profiles of Phosphoserine Bone Adhesive: Bridge from In Vitro to In Vivo.

Authors:  Kateřina Vrchovecká; Monika Pávková-Goldbergová; Håkan Engqvist; Michael Pujari-Palmer
Journal:  Biomedicines       Date:  2022-03-22

9.  Zirconia-Toughened Alumina Coated Ti6Al4V via Additive Manufacturing.

Authors:  Jose D Avila; Amit Bandyopadhyay
Journal:  Mater Lett       Date:  2021-02-19       Impact factor: 3.423

10.  Diabetes as a Risk Factor for Orthopedic Implant Surface Performance: A Retrieval and In Vitro Study.

Authors:  Alexandra Arteaga; Jiayi Qu; Sara Haynes; Brian G Webb; Javier LaFontaine; Danieli C Rodrigues
Journal:  J Bio Tribocorros       Date:  2021-02-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.