An analysis of fast imaging sequences with steady-state transverse magnetization refocusing.

Y Zur1, S Stokar, P Bendel.   

Abstract

Recently, several groups have proposed and demonstrated the use of rapid imaging methods, using short pulse repetition times and gradient-reversal echoes. Here, we analyze the behavior of the magnetization and the resulting image contrasts in such sequences for the case where the pulse repetition time TR is of the order of, or shorter than, the transverse relaxation time T2, and the transverse magnetization is not destroyed between phase-encoding cycles. Exact analytical expressions describing the signal evolution between the pulses are derived, taking into account the effects of resonance offsets and flip angles, and examining the influence of constant-phase or alternate-phase RF pulse trains. It is shown that for typical imaging sequences two distinct echo signals will develop between pulses, which may have a detrimental effect on image quality if they partially overlap within the sampling window. It is shown that artifact-free images can be obtained only if the two echo signals overlap precisely, which seems technically close to impossible to achieve, or if they are sufficiently separated in time to allow sampling of only one of the signals.

Mesh:

Year:  1988        PMID: 3367775     DOI: 10.1002/mrm.1910060206

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  45 in total

1.  Multishot EPI-SSFP in the heart.

Authors:  Daniel A Herzka; Peter Kellman; Anthony H Aletras; Michael A Guttman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2002-04       Impact factor: 4.668

2.  Steady-state free precession sequences in myocardial first-pass perfusion MR imaging: comparison with TurboFLASH imaging.

Authors:  Peter Hunold; Stefan Maderwald; Holger Eggebrecht; Florian M Vogt; Jörg Barkhausen
Journal:  Eur Radiol       Date:  2003-11-26       Impact factor: 5.315

3.  Fast imaging.

Authors:  J R Hesselink; J F Martin; R R Edelman
Journal:  Neuroradiology       Date:  1990       Impact factor: 2.804

4.  Limitations of rapid myelin water quantification using 3D bSSFP.

Authors:  C Lenz; M Klarhöfer; K Scheffler
Journal:  MAGMA       Date:  2010-04-28       Impact factor: 2.310

5.  T2 -prepared balanced steady-state free precession (bSSFP) for quantifying whole-blood oxygen saturation at 1.5T.

Authors:  Ana E Rodríguez-Soto; Osheiza Abdulmalik; Michael C Langham; Nadav Schwartz; Hyunyeol Lee; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2017-07-17       Impact factor: 4.668

6.  Improving contrast to noise ratio of resonance frequency contrast images (phase images) using balanced steady-state free precession.

Authors:  Jongho Lee; Masaki Fukunaga; Jeff H Duyn
Journal:  Neuroimage       Date:  2010-10-30       Impact factor: 6.556

7.  T2-weighted balanced steady-state free procession MRI evaluated for diagnosing placental adhesion disorder in late pregnancy.

Authors:  Ang Yang; Xue Hong Xiao; Zhi Long Wang; Ze Yan Wang; Ke Yi Wang
Journal:  Eur Radiol       Date:  2018-04-12       Impact factor: 5.315

8.  Ultra-Slow Single-Vessel BOLD and CBV-Based fMRI Spatiotemporal Dynamics and Their Correlation with Neuronal Intracellular Calcium Signals.

Authors:  Yi He; Maosen Wang; Xuming Chen; Rolf Pohmann; Jonathan R Polimeni; Klaus Scheffler; Bruce R Rosen; David Kleinfeld; Xin Yu
Journal:  Neuron       Date:  2018-02-21       Impact factor: 17.173

9.  Acute impairment of rat renal function by L -NAME as measured using dynamic MRI.

Authors:  Farid Sari-Sarraf; Silvia Pomposiello; Didier Laurent
Journal:  MAGMA       Date:  2008-07-26       Impact factor: 2.310

10.  Multiple repetition time balanced steady-state free precession imaging.

Authors:  Tolga Cukur; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2009-07       Impact factor: 4.668