| Literature DB >> 33660064 |
F Bürckenmeyer1, I Diamantis1, T Kriechenbauer1, T Lehmann2, T Franiel1, A Malouhi1, M O Grimm3, U Teichgräber1, R Aschenbach4.
Abstract
PURPOSE: To evaluate the effect of cone-beam computed tomography (CBCT) on radiation exposure, procedure time, and contrast media (CM) use in prostatic artery embolization (PAE).Entities:
Keywords: Cone-beam computed tomography; Contrast media; Dose-area product; Prostatic artery embolization; Radiation exposure
Mesh:
Substances:
Year: 2021 PMID: 33660064 PMCID: PMC8190013 DOI: 10.1007/s00270-021-02787-4
Source DB: PubMed Journal: Cardiovasc Intervent Radiol ISSN: 0174-1551 Impact factor: 2.740
Patients characteristics (n = 78)
| Group A ( | Group B ( | ||||
|---|---|---|---|---|---|
| Median [IQR] | Mean [ ± SD] | Median [IQR] | Mean [ ± SD] | ||
| Age, years | 66.8 [11,35] | 67.2 [ ± 7.8] | 67.6 [ | 69.1 [ ± 6] | 0.303 |
| IPSS | 25 [ | 24 [ ± 6] | 23 [ | 23 [ ± 7] | 0.334 |
| IIEF 5 | 17 [ | 15.6 [ ± 7.6] | 16 [ | 14.8 [ ± 7,7] | 0.645 |
| IIEF-EF | 21 [ | 19.3 [ ± 9.1] | 19 [ | 18.2 [ ± 9,1] | 0.552 |
| QoL | 5 [ | 4.8 [ ± 1.25] | 5 [ | 4.56 [ ± 1,25] | 0.283 |
| Peak urinary flow rate | 10 [ | 10.1 [ ± 3.8] | 9 [ | 9.6 [ ± 4] | 0.545 |
| Prostate volume, ml | 60 [36] | 66.7 [ ± 7.8] | 62 [37] | 72.2 [ ± 39,6] | 0.401 |
| Body mass index, kg/m2 | 26.5 [ | 26.9 [ ± 1.15] | 27.2 [ | 27.2 [ ± 0.9] | 0.206 |
IPSS international prostate symptom score, IIEF-5 international index of erectile function, IIEF-EF international index of erectile function erectile domain, QoL quality of life
Angiographic characteristics (n = 78)
| Group A | Group B | ||
|---|---|---|---|
| Number PA origin Type I | 50/78 (64.1%) | 51/78 (65.38%) | 1.000 |
| Number PA origin Type II | 13/78 (16.66%) | 12/78 (15.38%) | 1.000 |
| Number PA origin Type III | 3/78 (3.85%) | 5/78 (6.41%) | 0.719 |
| Number PA origin Type IV | 12/78 (15.38%) | 10/78 (12.82%) | 0.819 |
| Number PA origin Type V | 0/78 (0%) | 0/78 (0%) | 1.000 |
PA prostate artery, origins definded according to Assis et al
Type I: origin from the anterior division of internal iliac artery in a common trunk with the superior vesical artery (SVA)
Type II: origin from anterior division of internal iliac artery, inferior to SVA
Type III: origin from obturator artery
Type IV: origin from internal pudendal artery
Type V: less common origins
Results
| Group A ( | Group B ( | ||||||
|---|---|---|---|---|---|---|---|
| Median[IQR] | Mean [SD] 95% CI | % from total | Median[IQR] | Mean [SD] 95% CI | % from total | ||
| DAPtotal, Gycm2 | 236.94 [186.7] | 259.09 [ ± 145.62] | 281.20 [214.47] | 291.23 [ ± 162.59] | 0.345 | ||
| EDtotal, mSv | 25.82 [20.35] | 28,24 [± 15.87] | 39.84 [23.75] | 39.59 [ ± 18.5] | < 0.001* | ||
| ESDtotal, mGy | 2833 [2278] | 3036 [ ± 1889] | 2563 [3040] | 3243 [ ± 2055] | 0.818 | ||
| DAPCBCT, Gycm2 | n.a | n.a | 70.76 [ | 73.85 [ ± 13.53] | n.a | ||
| ESDCBCT, mGy | n.a | n.a | 232 [43.75] | 242.15 [ ± 44.06] | n.a | ||
| EDCBCT, mSv | n.a | n.a | 9.19 [1.71] | 9.6 [ ± 1.75] | n.a | ||
| % of CBCT from total ED | n.a | n.a | 23.06 | 24.24 | n.a | ||
| Number DSA series, n | 25 [ | 28 [ ± 13] | 23 [ | 24 [ ± 10] | 0.164 | ||
| Contrast media, ml | 65 [30] | 69.2 [ ± 33,2] | 114 [40] | 122.3 [ ± 25.6] | < 0.001* | ||
| Fluoroscopy time, min | 23 [ | 27.46 [ ± 14.43] | 28 [ | 29.74 [ ± 13.44] | 0.265 | ||
| Procedure time, min | 70[40] | 75.4 [ ± 28] | 120[40] | 123 [ ± 33] | < 0.001* | ||
| ESDfluoro, mGy | 252 [282] | 337.5[ ± 289] | 11.11 | 634 [603] | 780 [ ± 692] | 24.04 | < 0.001* |
| ESDseries, mGy | 2585 [2047] | 2699.28 [ ± 1735] | 88.88 | 2245 [2675] | 2463.59 [ ± 1635] | 75.96 | 0.5 |
| DAPfluoro, Gycm2 | 18.88 [24.82] | 24.50 [ ± 17.76] | 9.46 | 28.98 [30.44] | 42.57 [ ± 42.14] | 14.63 | 0.009* |
| DAPseries, mGy | 226.75 [174.5] | 234.59 [ ± 145.62] | 90.54 | 243.46 [206.31] | 248.65 [ ± 132.58] | 85.37 | 0.593 |
| Bilateral PAE, n (%) | 33/39 (84.6) | 32/39 (82.05) | 0.761** | ||||
ESD entrance skin dose, DSA digital subtraction angiography, IQR inter quartile ratio, SD standard deviation, DAP dose-area product, CBCT cone-beam computed tomography, ED effective dose (conversion factor 2D-DAP to ED: 0.109 mSv/Gycm2, DAPCBCT to ED: 0.13 mSv/Gycm2), *p value are significant different, **p-value calculated with two-sided Fisher´s exact test, PAE prostatic artery embolization, % from total is related to mean values