Prostatic artery embolization: radiation exposure to patients and staff.

W J Garzón1, G Andrade, F Dubourcq, D G Abud, M Bredow, H J Khoury, R Kramer.   

Abstract

The aim of this study was to evaluate the radiation doses to patients and staff received from the first cases of prostatic artery embolization (PAE) conducted in a public hospital in Recife, Brazil. Five PAE procedures for 5 men diagnosed with benign prostatic hyperplasia were investigated. In order to characterize patient exposure, dosimetric quantities, such as the air kerma-area product (P KA), the cumulative air kerma at the interventional reference point (Ka,r), the number of images, etc, were registered. To evaluate the possibility for deterministic effects, the peak skin dose (PSD) was measured using radiochromic films. For evaluation of personal dose equivalent and effective dose to the medical staff, thermoluminescent dosemeters (TLD-100) were used. The effective dose was estimated using the double dosimetry alghoritm of von Boetticher. The results showed that the mean patient's PSD per procedure was 2674.2 mGy. With regard to the medical staff, the mean, minimum and maximum effective doses estimated per procedure were: 18 μSv, 12 μSv and 21 μSv respectively. High personal equivalent doses were found for the feet, hands and lens of the eye, due to the use of multiple left anterior oblique projections and the improper use of the suspended lead screen and the lead curtain during procedures.

Entities:  

Mesh:

Year:  2016        PMID: 27025551     DOI: 10.1088/0952-4746/36/2/246

Source DB:  PubMed          Journal:  J Radiol Prot        ISSN: 0952-4746            Impact factor:   1.394


  3 in total

1.  Pitfalls in interventional X-ray organ dose assessment-combined experimental and computational phantom study: application to prostatic artery embolization.

Authors:  Philipp Roser; Annette Birkhold; Xia Zhong; Philipp Ochs; Elizaveta Stepina; Markus Kowarschik; Rebecca Fahrig; Andreas Maier
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-08-03       Impact factor: 2.924

2.  A Retrospective, Single-Center Study of Technical-Procedural Factors Affecting Radiation Dose During Prostatic Artery Embolization.

Authors:  Hippocrates Moschouris; Konstantinos Stamatiou; Nektarios Spanomanolis; Anastasios Vasilopoulos; Spiros Tzamarias; Katerina Malagari
Journal:  Cureus       Date:  2022-08-06

3.  Advanced image guidance for prostatic artery embolization - a multicenter technical note.

Authors:  Francisco Cesar Carnevale; Timothy McClure; Farah Cadour; Vincent Vidal; André Moreira de Assis; Airton Mota Moreira; Arthur Diego Dias Rocha; Aya Rebet; Charles Nutting
Journal:  CVIR Endovasc       Date:  2021-08-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.