Literature DB >> 16557104

Noninvasive continuous monitoring of digital pulse waves during hemodialysis.

Antje Burkert1, Alexandra Scholze, Martin Tepel.   

Abstract

Intermittent hemodynamic instability during hemodialysis treatment is a frequent complication in patients with end-stage renal failure. A noninvasive method for continuous hemodynamic monitoring is needed. We used noninvasive digital photoplethysmography and an algorithm for continuous, investigator-independent, automatic analysis of digital volume pulse in 10 healthy subjects and in 20 patients with end-stage renal failure during the hemodialysis session. The reflective index was defined representing the diastolic component of the digital pulse wave. The properties of the reflective index were studied in healthy control subjects (n=10). An increased reflective index was due to increased peripheral pulse wave reflection (e.g., vasoconstriction). During a hemodialysis session, the reflective index increased significantly from 36+/-3 arbitrary units to 41+/-3 arbitrary units (n=20; p<0.05) measured using digital photoplethysmography. This increase appeared in 15 of the 20 patients with end-stage renal failure. Our data establish digital photoplethysmography as a noninvasive, reliable, and sensitive method for continuous monitoring during the hemodialysis session.

Entities:  

Mesh:

Year:  2006        PMID: 16557104     DOI: 10.1097/01.mat.0000199892.82612.8e

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  4 in total

1.  Investigation of peripheral photoplethysmographic morphology changes induced during a hand-elevation study.

Authors:  Michelle Hickey; Justin P Phillips; Panayiotis A Kyriacou
Journal:  J Clin Monit Comput       Date:  2015-08-29       Impact factor: 2.502

2.  Evaluation of intradialytic hypotension using impedance cardiography.

Authors:  Abed Bayya; Dvora Rubinger; David Michael Linton; Sigal Sviri
Journal:  Int Urol Nephrol       Date:  2010-05-07       Impact factor: 2.370

3.  System of integrating biosignals during hemodialysis: the CONTINUAL (Continuous mOnitoriNg viTal sIgN dUring hemodiALysis) registry.

Authors:  Seonmi Kim; Donghwan Yun; Soonil Kwon; So-Ryoung Lee; Kwangsoo Kim; Yong Chul Kim; Dong Ki Kim; Kook-Hwan Oh; Kwon Wook Joo; Hyung-Chul Lee; Chul-Woo Jung; Yon Su Kim; Seung Seok Han
Journal:  Kidney Res Clin Pract       Date:  2022-05-23

4.  Optical coherence tomography angiography measures blood pulsatile waveforms at variable tissue depths.

Authors:  Zhiying Xie; Geng Wang; Yuxuan Cheng; Qinqin Zhang; Minh Nhan Le; Ruikang K Wang
Journal:  Quant Imaging Med Surg       Date:  2021-03
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.