Quantitative Comparison of Photoplethysmographic Waveform Characteristics: Effect of Measurement Site.

Vera Hartmann1, Haipeng Liu1,2, Fei Chen2, Qian Qiu1, Stephen Hughes1, Dingchang Zheng1.   

Abstract

Introduction: Photoplethysmography (PPG) has been widely used to assess cardiovascular function. However, few studies have comprehensively investigated the effect of measurement site on PPG waveform characteristics. This study aimed to provide a quantitative comparison on this.
Methods: Thirty six healthy subjects participated in this study. For each subject, PPG signals were sequentially recorded for 1 min from six different body sites (finger, wrist under (anatomically volar), wrist upper (dorsal), arm, earlobe, and forehead) under both normal and deep breathing patterns. For each body site under a certain breathing pattern, the mean amplitude was firstly derived from recorded PPG waveform which was then normalized to derive several waveform characteristics including the pulse peak time (Tp), dicrotic notch time (Tn), and the reflection index (RI). The effects of breathing pattern and measurement site on the waveform characteristics were finally investigated by the analysis of variance (ANOVA) with post hoc multiple comparisons.
Results: Under both breathing patterns, the PPG measurements from the finger achieved the highest percentage of analyzable waveforms for extracting waveform characteristics. There were significant effects of breathing pattern on Tn and RI (larger Tn and smaller RI with deep breathing on average, both p < 0.03). The effects of measurement site on mean amplitude, Tp, Tn, and RI were significant (all p < 0.001). The key results were that, under both breathing patterns, the mean amplitude from finger PPG was significantly larger and its Tp and RI were significantly smaller than those from the other five sites (all p < 0.001, except p = 0.04 for the Tp of "wrist under"), and Tn was only significantly larger than that from the earlobe (both p < 0.05).
Conclusion: This study has quantitatively confirmed the effect of PPG measurement site on PPG waveform characteristics (including mean amplitude, Tp, Tn, and RI), providing scientific evidence for a better understanding of the PPG waveform variations between different body sites.

Entities:  

Keywords:  PPG waveform analysis; breathing pattern; multi-site PPG; photoplethysmography; pulse wave analysis

Year:  2019        PMID: 30890959      PMCID: PMC6412091          DOI: 10.3389/fphys.2019.00198

Source DB:  PubMed          Journal:  Front Physiol        ISSN: 1664-042X            Impact factor:   4.566


  21 in total

1.  Wearable Photoplethysmography for Cardiovascular Monitoring.

Authors:  Peter H Charlton; Panicos A Kyriaco; Jonathan Mant; Vaidotas Marozas; Phil Chowienczyk; Jordi Alastruey
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2022-03-11       Impact factor: 10.961

Review 2.  Diabetes Detection and Management through Photoplethysmographic and Electrocardiographic Signals Analysis: A Systematic Review.

Authors:  Serena Zanelli; Mehdi Ammi; Magid Hallab; Mounim A El Yacoubi
Journal:  Sensors (Basel)       Date:  2022-06-29       Impact factor: 3.847

3.  Optical coherence tomography angiography measures blood pulsatile waveforms at variable tissue depths.

Authors:  Zhiying Xie; Geng Wang; Yuxuan Cheng; Qinqin Zhang; Minh Nhan Le; Ruikang K Wang
Journal:  Quant Imaging Med Surg       Date:  2021-03

4.  Wearable Cuff-Less Blood Pressure Estimation at Home via Pulse Transit Time.

Authors:  Venu G Ganti; Andrew M Carek; Brandi N Nevius; J Alex Heller; Mozziyar Etemadi; Omer T Inan
Journal:  IEEE J Biomed Health Inform       Date:  2021-06-03       Impact factor: 7.021

5.  Detection of Atrial Fibrillation Using a Ring-Type Wearable Device (CardioTracker) and Deep Learning Analysis of Photoplethysmography Signals: Prospective Observational Proof-of-Concept Study.

Authors:  Soonil Kwon; Joonki Hong; Eue-Keun Choi; Byunghwan Lee; Changhyun Baik; Euijae Lee; Eui-Rim Jeong; Bon-Kwon Koo; Seil Oh; Yung Yi
Journal:  J Med Internet Res       Date:  2020-05-21       Impact factor: 5.428

6.  Assessing the Quality of Heart Rate Variability Estimated from Wrist and Finger PPG: A Novel Approach Based on Cross-Mapping Method.

Authors:  Mimma Nardelli; Nicola Vanello; Guenda Galperti; Alberto Greco; Enzo Pasquale Scilingo
Journal:  Sensors (Basel)       Date:  2020-06-02       Impact factor: 3.576

7.  Quantitative Comparison of the Performance of Piezoresistive, Piezoelectric, Acceleration, and Optical Pulse Wave Sensors.

Authors:  Hongju Wang; Lu Wang; Nannan Sun; Yang Yao; Liling Hao; Lisheng Xu; Stephen E Greenwald
Journal:  Front Physiol       Date:  2020-01-14       Impact factor: 4.566

8.  Can the Vaginal Photoplethysmograph and Its Associated Methodology Be Used to Assess Anal Vasocongestion in Women and Men?

Authors:  Megan L Sawatsky; Kelly D Suschinsky; Sofija Lavrinsek; Meredith L Chivers; Martin L Lalumière
Journal:  Arch Sex Behav       Date:  2021-06-18

9.  Coherence between Decomposed Components of Wrist and Finger PPG Signals by Imputing Missing Features and Resolving Ambiguous Features.

Authors:  Pei-Yun Tsai; Chiu-Hua Huang; Jia-Wei Guo; Yu-Chuan Li; An-Yeu Andy Wu; Hung-Ju Lin; Tzung-Dau Wang
Journal:  Sensors (Basel)       Date:  2021-06-24       Impact factor: 3.576

10.  Influence of mental stress on the pulse wave features of photoplethysmograms.

Authors:  Patrick Celka; Peter H Charlton; Bushra Farukh; Philip Chowienczyk; Jordi Alastruey
Journal:  Healthc Technol Lett       Date:  2019-11-26