Literature DB >> 10992017

Complications of endovascular repair for thoracic and abdominal aortic aneurysm: an imaging spectrum.

T Mita1, T Arita, N Matsunaga, M Furukawa, N Zempo, K Esato, M Matsuzaki.   

Abstract

Endovascular stent-graft implantation is an alternative to conventional open surgery for the treatment of aortic aneurysm. Forty-nine consecutive patients with aortic aneurysm (thoracic, n = 17; infrarenal, n = 32) were treated with endovascular stent-graft implantation. Complications occurred in 25 patients (two patients had two complications): endoleak (n = 13), graft thrombosis (n = 5), graft kinking (n = 2), pseudoaneurysm caused by graft infection (n = 1), graft occlusion (n = 1), shower embolism (n = 1), perforation of mural thrombus by means of inadvertent penetration of delivery system (n = 1), colon necrosis (n = 1), aortic dissection (n = 1), and hematoma at the arteriotomy site (n = 1). Imaging findings were analyzed for spiral computed tomography, plain abdominal radiography, transesophageal echocardiography, and digital subtraction angiography. Since some of these complications are fatal, radiologists need to instantly and accurately recognize them. Awareness and understanding of possible complications should help ensure a safe, successful procedure.

Entities:  

Mesh:

Year:  2000        PMID: 10992017     DOI: 10.1148/radiographics.20.5.g00se161263

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  12 in total

1.  Thoracic aortic stent graft: comparison of contrast-enhanced MR angiography and CT angiography in the follow-up: initial results.

Authors:  Stefanie Weigel; Bernd Tombach; David Maintz; Stefan Klotz; Thomas Vestring; Walter Heindel; Roman Fischbach
Journal:  Eur Radiol       Date:  2003-02-19       Impact factor: 5.315

2.  Unusual complications of endovascular repair of the thoracic aorta: MDCT findings.

Authors:  T Valente; G Rossi; F Lassandro; G Rea; M Marino; G Dialetto; R Muto; M Scaglione
Journal:  Radiol Med       Date:  2012-01-07       Impact factor: 3.469

Review 3.  Dual energy CT: preliminary observations and potential clinical applications in the abdomen.

Authors:  Anno Graser; Thorsten R C Johnson; Hersh Chandarana; Michael Macari
Journal:  Eur Radiol       Date:  2008-08-02       Impact factor: 5.315

4.  Non-contrast MR imaging for detecting endoleak after abdominal endovascular aortic repair.

Authors:  Elda C Resta; Francesco Secchi; Antonello Giardino; Veronica G Nardella; Giovanni Di Leo; Nicola Flor; Francesco Sardanelli
Journal:  Int J Cardiovasc Imaging       Date:  2012-05-16       Impact factor: 2.357

5.  Associated gastroduodenal artery aneurysm aortic aneurysm: the diagnostic contribution of contrast-enhanced ultrasound in correlation with computed tomography angiography.

Authors:  Radu Badea; Liliana Chiorean; Olimpia Chira; Cosmin Caraiani
Journal:  J Med Ultrason (2001)       Date:  2013-11-16       Impact factor: 1.314

6.  Reoperations after failure of stent grafting for type B aortic dissection: report of two cases.

Authors:  Jorge Flores; Norihiko Shiiya; Takashi Kunihara; Kimihiro Yoshimoto; Kenji Matsuzaki; Keishu Yasuda
Journal:  Surg Today       Date:  2005       Impact factor: 2.549

7.  Complications after endovascular aneurysm repair.

Authors:  Geert Maleux; Marcel Koolen; Sam Heye
Journal:  Semin Intervent Radiol       Date:  2009-03       Impact factor: 1.513

8.  Hybrid-repair of thoraco-abdominal or juxtarenal aortic aneurysm: what the radiologist should know.

Authors:  Tobias Krauss; Thomas Pfammatter; Dieter Mayer; Mario Lachat; Lukas Hechelhammer; Borut Marincek; Thomas Frauenfelder
Journal:  Eur Radiol       Date:  2009-09-30       Impact factor: 5.315

9.  Multi-detector CT angiographic imaging in the follow-up of patients after endovascular abdominal aortic aneurysm repair (EVAR).

Authors:  Roberto Iezzi; M Santoro; R Dattesi; F Pirro; M Nestola; F Spigonardo; A R Cotroneo; L Bonomo
Journal:  Insights Imaging       Date:  2012-06-12

10.  Advantages and disadvantages of single-source dual-energy whole-body CT angiography with 50% reduced iodine dose at 40 keV reconstruction.

Authors:  Yoshifumi Noda; Fumihiko Nakamura; Noriyuki Yasuda; Toshiharu Miyoshi; Nobuyuki Kawai; Hiroshi Kawada; Fuminori Hyodo; Masayuki Matsuo
Journal:  Br J Radiol       Date:  2021-02-22       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.