Literature DB >> 15543865

Tetrapolar measurement of electrical conductivity and thickness of articular cartilage.

J S Binette1, M Garon, P Savard, M D McKee, M D Buschmann.   

Abstract

A tetrapolar method to measure electrical conductivity of cartilage and bone, and to estimate the thickness of articular cartilage attached to bone, was developed. We determined the electrical conductivity of humeral head bovine articular cartilage and subchondral bone from a 1- to 2-year-old steer to be 1.14+/-0.11 S/m (mean+/-sd, n =11) and 0.306+/-0.034 S/m, (mean+/-sd, n =3), respectively. For a 4-year-old cow, articular cartilage and subchondral bone electrical conductivity were 0.88+/-0.08 S/m (mean+/-sd, n =9) and 0.179+/-0.046 S/m (mean+/-sd, n =3), respectively. Measurements on slices of cartilage taken from different distances from the articular surface of the steer did not reveal significant depth-dependence of electrical conductivity. We were able to estimate the thickness of articular cartilage with reasonable precision (<20% error) by injecting current from multiple electrode pairs with different inter-electrode distances. Requirements for the precision of this method to measure cartilage thickness include the presence of a distinct layer of calcified cartilage or bone with a much lower electrical conductivity than that of uncalcified articular cartilage, and the use of inter-electrode distances of the current injecting electrodes that are on the order of the cartilage thickness. These or similar methods present an attractive approach to the non-destructive determination of cartilage thickness, a parameter that is required in order to estimate functional properties of cartilage attached to bone, and evaluate the need for therapeutic interventions in arthritis.

Entities:  

Mesh:

Year:  2004        PMID: 15543865     DOI: 10.1115/1.1785805

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  9 in total

1.  Tensorial electrokinetics in articular cartilage.

Authors:  Boris Reynaud; Thomas M Quinn
Journal:  Biophys J       Date:  2006-06-23       Impact factor: 4.033

2.  Forward and inverse electroencephalographic modeling in health and in acute traumatic brain injury.

Authors:  Andrei Irimia; S Y Matthew Goh; Carinna M Torgerson; Micah C Chambers; Ron Kikinis; John D Van Horn
Journal:  Clin Neurophysiol       Date:  2013-06-06       Impact factor: 3.708

3.  Measurement of the low-frequency charge noise of bacteria.

Authors:  Yichao Yang; Hagen Gress; Kamil L Ekinci
Journal:  Phys Rev E       Date:  2022-06       Impact factor: 2.707

4.  Spatially resolved streaming potentials of human intervertebral disk motion segments under dynamic axial compression.

Authors:  James C Iatridis; Masaru Furukawa; Ian A F Stokes; Mack G Gardner-Morse; Jeffrey P Laible
Journal:  J Biomech Eng       Date:  2009-03       Impact factor: 2.097

5.  An Instrumented Cochlea Model for the Evaluation of Cochlear Implant Electrical Stimulus Spread.

Authors:  Chen Jiang; Shreya Singhal; Thomas Landry; Iwan Roberts; Simone de Rijk; Tim Brochier; Tobias Goehring; Yu Tam; Robert Carlyon; George Malliaras; Manohar Bance
Journal:  IEEE Trans Biomed Eng       Date:  2021-06-17       Impact factor: 4.538

Review 6.  Endogenous Electric Signaling as a Blueprint for Conductive Materials in Tissue Engineering.

Authors:  Alena Casella; Alyssa Panitch; J Kent Leach
Journal:  Bioelectricity       Date:  2021-03-16

7.  In vivo electrical conductivity measurement of muscle, cartilage, and peripheral nerve around knee joint using MR-electrical properties tomography.

Authors:  Ji Hyun Lee; Young Cheol Yoon; Hyun Su Kim; Jiyeong Lee; Eunju Kim; Christian Findeklee; Ulrich Katscher
Journal:  Sci Rep       Date:  2022-01-07       Impact factor: 4.379

8.  Numerical Simulations as Means for Tailoring Electrically Conductive Hydrogels Towards Cartilage Tissue Engineering by Electrical Stimulation.

Authors:  Julius Zimmermann; Thomas Distler; Aldo R Boccaccini; Ursula van Rienen
Journal:  Molecules       Date:  2020-10-16       Impact factor: 4.411

Review 9.  Piezoelectric Electrospun Fibrous Scaffolds for Bone, Articular Cartilage and Osteochondral Tissue Engineering.

Authors:  Frederico Barbosa; Frederico Castelo Ferreira; João Carlos Silva
Journal:  Int J Mol Sci       Date:  2022-03-08       Impact factor: 5.923

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.