Literature DB >> 27616540

Changes in Root Canal Length Determined during Mechanical Preparation Stages and Their Relationship with the Accuracy of Root ZX II.

Bruno Carvalho Vasconcelos1, Luzia Mesquista Bastos2, Ariany Souza Oliveira2, Ricardo Affonso Bernardes3, Marco Antonio Hungaro Duarte4, Nilton Vivacqua-Gomes5, Rodrigo Ricci Vivan4.   

Abstract

INTRODUCTION: The aim of this study was to determine the variations in root canal length (RCL) occurring during endodontic treatment stages (initial, preflared, and concluded) and correlate them with the accuracy of Root ZX II (RZX).
METHODS: After coronal access, 26 mandibular molars had the apical foramen of the 52 mesial canals standardized (250 μm) and their respective initial RCL was recorded (RCL1 = initial) by using a clinical microscope (×16) and manual K-file instruments. By using the alginate model, sequential electronic measurements were taken with the RZX. After the initial measurement (EM1), WaveOne Primary instruments were used to prepare the cervical and middle thirds of the root canals, and then the second RCL and EM measurements (RCL2/EM2 = preflared) were obtained. Finally, mechanical preparation was concluded, and the measurement procedures were repeated to obtain the final RCL and EM measurements (RCL3/EM3 = concluded).
RESULTS: Statistically significant differences were observed in all comparisons in the RCL (P < .05). The RCL1 - RCL3 showed the highest variation (0.6 mm), with the extent of specimens reduced by up to 1.75 mm. No statistically significant differences were found in the accuracy of the RZX (P > .05); 100% precision (± 0.5 mm) was found in all stages.
CONCLUSIONS: Under the conditions of this study, the authors concluded that during endodontic treatment, the extent of the RCL was reduced, thereby jeopardizing control of the apical limit during instrumentation and/or obturation. The RZX was extremely accurate in all evaluated stages.
Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Electronic foramen locator; endodontic; root canal length

Mesh:

Year:  2016        PMID: 27616540     DOI: 10.1016/j.joen.2016.07.022

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  4 in total

1.  The influence of periapical lesions on the repeatability of two electronic apex locators in vivo.

Authors:  Carlos G Adorno; Sandra M Solaeche; Ileana E Ferreira; Andrea Pedrozo; Patricia M Escobar; Vicente R Fretes
Journal:  Clin Oral Investig       Date:  2021-02-13       Impact factor: 3.573

2.  Comparison of Radiovisiography, an Apex Locator and an Integrated Endomotor-inbuilt Apex Locator in Primary Teeth Endometrics.

Authors:  Suleman Abbas Khan; Rinee Khanna; Saumya Navit; Seema Jabeen; Nishi Grover; Saurabh Pramanik
Journal:  Int J Clin Pediatr Dent       Date:  2022

3.  Root ZX Electronic Foramen Locator: An Ex Vivo Study of Its Three Models' Precision and Reproducibility.

Authors:  Bernardo Almeida Aguiar; Rafael Santos Reinaldo; Luciana Maria Arcanjo Frota; Mônica Sampaio do Vale; Bruno Carvalho de Vasconcelos
Journal:  Int J Dent       Date:  2017-03-07

4.  Canal Straightening Following Overinstrumentation with Three Nickel-Titanium Rotary Instruments.

Authors:  Salwa Yammine; Edgard Jabbour; Franck Diemer; Zeina Majzoub
Journal:  J Int Soc Prev Community Dent       Date:  2018-05-17
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.