Literature DB >> 27986097

Endodontic Working Length Measurement Using Cone-beam Computed Tomographic Images Obtained at Different Voxel Sizes and Field of Views, Periapical Radiography, and Apex Locator: A Comparative Ex Vivo Study.

Funda Yılmaz1, Kıvanç Kamburoğlu2, Buğra Şenel3.   

Abstract

INTRODUCTION: The aim of this study was to evaluate the accuracy of working length determination by using an electronic apex locator, periapical radiography, and cone-beam computed tomographic (CBCT) imaging obtained at different voxel sizes and field of views (FOVs) in extracted human teeth.
METHODS: Thirty extracted human mandibular premolar teeth were used. The electronic working length measurements were performed by using an electronic apex locator (Root ZX; J Morita Corp, Kyoto, Japan). Five different image sets were obtained as follows: (1) CBCT imaging: 40 × 40 mm FOV, 0.080 mm3 (FOV40); (2) CBCT imaging: 60 × 60 mm FOV, 0.125 mm3 (FOV60); (3) CBCT imaging: 80 × 80 mm FOV, 0.160 mm3 (FOV80); (4) CBCT imaging: 100 × 100 mm FOV, 0.250 mm3 (FOV100); and (5) periapical digital radiography. Direct measurements performed with an electronic digital caliper were considered as the gold standard and compared with the electronic apex locator, CBCT, and periapical image measurements. Data were analyzed using a 2-way analysis of variance test. Significance level was set at P < .05.
RESULTS: There was no significant difference between or within operators in intraoral radiographs (P > .05 and the Gage R&R value was <30%). There were significant differences between and within operators for CBCT images (P < .05 and Gage R&R value was >30%). There were significant differences in the methods in terms of mean differences from the gold standard (P < .05).
CONCLUSIONS: This study showed that available CBCT scans with different FOVs can be used for working length measurement.
Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Apex locator; cone-beam computed tomography; endodontics; measurement; radiography; working length

Mesh:

Year:  2017        PMID: 27986097     DOI: 10.1016/j.joen.2016.09.019

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  13 in total

1.  The influence of periapical lesions on the repeatability of two electronic apex locators in vivo.

Authors:  Carlos G Adorno; Sandra M Solaeche; Ileana E Ferreira; Andrea Pedrozo; Patricia M Escobar; Vicente R Fretes
Journal:  Clin Oral Investig       Date:  2021-02-13       Impact factor: 3.573

Review 2.  Is the quality of root canal filling obtained by cone-beam computed tomography associated with periapical lesions? A systematic review and meta-analysis.

Authors:  Guilherme Nilson Alves Dos Santos; André Luis Faria-E-Silva; Vitor Luís Ribeiro; Laís Lima Pelozo; Amanda Pelegrin Candemil; Matheus L Oliveira; Fabiane Carneiro Lopes-Olhê; Jardel Francisco Mazzi-Chaves; Manoel Damião Sousa-Neto
Journal:  Clin Oral Investig       Date:  2022-05-26       Impact factor: 3.606

Review 3.  Use of preoperative cone-beam computed tomography to aid in establishment of endodontic working length: A systematic review and meta-analysis.

Authors:  Andrew Paterson; Vittorio Franco; Shanon Patel; Federico Foschi
Journal:  Imaging Sci Dent       Date:  2020-09-16

4.  Canal Straightening Following Overinstrumentation with Three Nickel-Titanium Rotary Instruments.

Authors:  Salwa Yammine; Edgard Jabbour; Franck Diemer; Zeina Majzoub
Journal:  J Int Soc Prev Community Dent       Date:  2018-05-17

5.  Endodontic Length Measurements Using Different Modalities: An In Vitro Study.

Authors:  Phuc Ngoc Nguyen; Khoa Van Pham
Journal:  J Int Soc Prev Community Dent       Date:  2020-11-24

6.  Root canal length measurement of molar teeth using conebeam computed tomography (CBCT): comparison of two dimensional versus three-dimensional methods.

Authors:  Selen Nihal Sisli; Orhan Gulen
Journal:  Eur Oral Res       Date:  2021-05-04

7.  Influence and safety of electronic apex locators in patients with cardiovascular implantable electronic devices: a systematic review.

Authors:  Mothanna K AlRahabi; Hani M Ghabbani
Journal:  Libyan J Med       Date:  2019-12       Impact factor: 1.657

8.  In vitro Evaluation of the Accuracy of the Root Zx in the Presence of Naocl 2.5% and Chlorhexidine 0.2.

Authors:  Marjan Bolbolian; Siamak Golchin; Seyedmatin Faegh
Journal:  J Clin Exp Dent       Date:  2018-11-01

9.  Correlation of objective image quality and working length measurements in different CBCT machines: An ex vivo study.

Authors:  T G Wolf; F Fischer; R K W Schulze
Journal:  Sci Rep       Date:  2020-11-10       Impact factor: 4.379

10.  Preoperative Estimation of Endodontic Working Length with Cone-Beam Computed Tomography and Standardized Paralleling Technique in comparison to Its Real Length.

Authors:  Bestoon Mohammed Faraj
Journal:  Biomed Res Int       Date:  2020-10-10       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.