Noninvasive assessment of cardiac performance by impedance cardiography: disagreement between two equations to estimate stroke volume.

C de Mey1, D Enterling.   

Abstract

Impedance cardiography, phonocardiography, and ECG were registered prior to, during, and after 10 min of gradual passive upright tilt in 35 normal male subjects. Stroke volume (SV) was estimated according to both the standard equation of Kubicek et al. and a newly introduced equation by Sramek et al. Sramek's equation estimated larger SV values throughout. It furthermore estimated a larger SV response to upright tilt: a bias of -17 ml (95% Cl: -20 to -13) was identified for Sramek's minus Kubicek's approach. Corresponding disagreement was identified for cardiac output and systemic vascular resistance derived from SV. A far better agreement was identified when the data were expressed as percent of the supine base line prior to tilt. Under such transformation, Sramek's approach estimated slightly smaller SV responses to tilt: a bias of 4.2% (95% Cl: 3.6 to 4.7) was identified for the percent response of SV to upright tilt for Sramek's minus Kubicek's equation. Data generated by these two equations are, nevertheless, not readily interchangeable nor comparable. As Sramek's equation estimated consistently larger SV values than Kubicek's equation, it is unlikely that Sramek's equation could solve the issue of the quantitative inaccuracy which remains intrinsic to the usage of Kubicek's equation in impedance cardiography.

Entities:  

Mesh:

Year:  1988        PMID: 3355468

Source DB:  PubMed          Journal:  Aviat Space Environ Med        ISSN: 0095-6562


  10 in total

1.  A comparative assessment of two techniques for investigating initial cardiovascular reflexes under acute orthostatic stress.

Authors:  Caroline A Rickards; David G Newman
Journal:  Eur J Appl Physiol       Date:  2003-07-19       Impact factor: 3.078

2.  Agreement and reproducibility of the estimates of cardiovascular function by impedance cardiography and M-mode echocardiography in healthy subjects.

Authors:  C de Mey; J Matthews; R Butzer; V Schroeter; G G Belz
Journal:  Br J Clin Pharmacol       Date:  1992-07       Impact factor: 4.335

3.  Descending aortic flow contribution to intrathoracic impedance-development and preliminary testing of a dual impedance model.

Authors:  A Barry Baker; Chris N McLeod; Alastair J Roxburgh; Paul Bannister
Journal:  J Clin Monit Comput       Date:  2007-11-15       Impact factor: 2.502

4.  Comparison of impedance cardiography and dye dilution method for measuring cardiac output.

Authors:  W Spiering; P N van Es; P W de Leeuw
Journal:  Heart       Date:  1998-05       Impact factor: 5.994

5.  Comparison of two impedance cardiographic techniques for measuring cardiac output.

Authors:  R W Gotshall; V C Wood; D S Miles
Journal:  Ann Biomed Eng       Date:  1989       Impact factor: 3.934

6.  Impedance cardiography. Importance of the equation and the electrode configuration.

Authors:  B J van der Meer; H H Woltjer; A M Sousman; W O Schreuder; E R Bulder; M A Huybregts; P M de Vries
Journal:  Intensive Care Med       Date:  1996-10       Impact factor: 17.440

7.  Pitfalls and limitations in the use of impedance cardiography.

Authors:  C de Mey; G G Belz
Journal:  Br Heart J       Date:  1989-01

8.  The influence of weight on stroke volume determination by means of impedance cardiography in cardiac surgery patients.

Authors:  H H Woltjer; H J Bogaard; H I van der Spoel; P M de Vries
Journal:  Intensive Care Med       Date:  1996-08       Impact factor: 17.440

9.  Comparison between spot and band electrodes and between two equations for calculations of stroke volume by means of impedance cardiography.

Authors:  H H Woltjer; B J van der Meer; H J Bogaard; P M de Vries
Journal:  Med Biol Eng Comput       Date:  1995-05       Impact factor: 2.602

10.  Disagreement between standard transthoracic impedance cardiography and the automated transthoracic electrical bioimpedance method in estimating the cardiovascular responses to phenylephrine and isoprenaline in healthy man.

Authors:  C De Mey; D Enterling
Journal:  Br J Clin Pharmacol       Date:  1993-04       Impact factor: 4.335

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.