Michael Dommasch1, Alexander Steger1, Petra Barthel1, Katharina M Huster1, Alexander Müller1, Daniel Sinnecker1, Karl-Ludwig Laugwitz1,2, Thomas Penzel3, Andrzej Lubinski4, Panagiota Flevari5, Markus Harden6, Tim Friede6,7, Stefan Kääb2,8, Bela Merkely9, Christian Sticherling10, Rik Willems11, Heikki V Huikuri12, Axel Bauer2,8,13, Marek Malik14,15, Markus Zabel7,16, Georg Schmidt1,2.
Abstract
BACKGROUND: Implantable cardioverter defibrillators (ICDs) prevent sudden cardiac death. ICD implantation decisions are currently based on reduced left ventricular ejection fraction (LVEF≤35%). However, in some patients, the non-arrhythmic death risk predominates thus diminishing ICD-therapy benefits. Based on previous observations, we tested the hypothesis that compared to the others, patients with nocturnal respiratory rate (NRR) ≥18 breaths per minute (brpm) benefit less from prophylactic ICD implantations.Entities:
Keywords: Benefit prediction; Nocturnal respiratory rate; Primary prophylactic ICD
Year: 2020 PMID: 33554086 PMCID: PMC7846675 DOI: 10.1016/j.eclinm.2020.100695
Source DB: PubMed Journal: EClinicalMedicine ISSN: 2589-5370
Fig. 1Study flow chart
EU-CERT-ID=EUropean Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators. ECGs=electrocardiograms. ICD=implantable cardioverter defibrillator.
Baseline characteristics and treatments of patients in the ICD and control groups.
| Baseline characteristics | ICD group | Control group | Standardized difference | ||
|---|---|---|---|---|---|
| Number of patients | 1363 | 608 | |||
| Female | 244 | (17.9) | 108 | (17.8) | 0.00 |
| Region | 0.69 | ||||
| Eastern | 578 | (42.4) | 400 | (65.8) | |
| Northern | 139 | (10.2) | 29 | (4.8) | |
| Southern | 70 | (5.1) | 75 | (12.3) | |
| Western | 576 | (42.3) | 104 | (17.1) | |
| Age [years] | 61.7 | 11.6 | 63.2 | 11.7 | −0.13 |
| BMI [kg/m²] | 27.7 | 5.2 | 28.1 | 4.9 | −0.07 |
| Creatinine [mg/dL] | 1.2 | 0.6 | 1.2 | 0.6 | −0.13 |
| Diastolic blood pressure [mmHg] | 73.8 | 11.1 | 74.9 | 10.9 | −0.10 |
| Haemoglobin [g/dL] | 13.8 | 1.9 | 13.9 | 1.7 | −0.01 |
| LVEF [%] | 27.5 | 5.5 | 29.0 | 5.6 | −0.28 |
| NRR [brpm] | 17.1 | 3.1 | 17.9 | 3.8 | −0.22 |
| QTc [ms] | 438.4 | 39.0 | 433.9 | 44.2 | 0.11 |
| QRS [ms] | 106.4 | 17.3 | 103.8 | 18.2 | 0.15 |
| Sodium [mmol/L] | 139.1 | 3.2 | 139.4 | 3.3 | −0.09 |
| AF (history or present) | 334 | (24.5) | 169 | (27.8) | −0.07 |
| Chronic obstructive pulmonary disease | 157 | (11.5) | 58 | (9.5) | 0.06 |
| Diabetes | 408 | (29.9) | 185 | (30.4) | −0.01 |
| Leading cardiac disease | −0.25 | ||||
| ischaemic cardiomyopathy | 939 | (68.9) | 345 | (56.7) | |
| Dilated cardiomyopathy | 424 | (31.1) | 263 | (43.3) | 0.01 |
| Malignant disease | 60 | (4.4) | 25 | (4.1) | −0.17 |
| NYHA class | |||||
| Class I or II | 857 | (62.9) | 333 | (54.8) | |
| Class III or IV | 506 | (37.1) | 275 | (45.2) | |
| Sleep apnoea with or without airway pressure treatment | 62 | (4.5) | 15 | (2.5) | 0.11 |
| Tobacco use | 887 | (65.1) | 298 | (49.0) | 0.33 |
| Amiodarone | 100 | (7.3) | 89 | (14.6) | −0.24 |
| AT1 antagonist | 266 | (19.5) | 149 | (24.5) | −0.12 |
| Beta-blocker | 1291 | (94.7) | 566 | (93.1) | 0.07 |
| Loop diuretic | 951 | (69.8) | 466 | (76.6) | −0.16 |
Incidence variables are shown as absolute number (%), numerical variables as mean (standard deviation). Regions: Eastern Europe: Hungary, Bulgaria, Croatia, Poland, Slovakia, and the Czech Republic, Northern Europe: Denmark, Sweden and Finland, Southern Europe: Spain and Greece, Western Europe: Germany, Belgium, Netherlands, and Switzerland. ICD=implantable cardioverter defibrillator. AF=atrial fibrillation, AT1=angiotensin 1, LVEF=left ventricular ejection fraction, NYHA=New York Heart Association.
Fig. 2ICD treatment effect as a function of nocturnal respiratory rate
Adjusted hazard ratios (ICD group vs control group) for mortality are shown. The solid line shows point estimates, and the broken lines show the 95% CIs. ICD=implantable cardioverter defibrillator.
Fig. 3Unadjusted cumulative mortality in the ICD and control groups in patients with nocturnal respiratory rate ≥18 brpm and <18brpm. ICD=implantable cardioverter defibrillator.
Fig. 4Adjusted hazard ratios for the ICD group vs the control group
Error bars represent 95% CIs. ICD=implantable cardioverter defibrillator.