Massimo Castellucci1, Costanza Novara1, Alessandra Casuccio2, Giovannni Cillino1, Carla Giordano3, Valentina Failla1, Vincenza Bonfiglio1, Maria Vadalà1, Salvatore Cillino1. 1. Department of Biomedicine, Neurosciences and Advanced Diagnostic, Ophthalmology Section, University of Palermo, 90127 Palermo, Italy. 2. Department of Health Promotion, Mother Child Care, Internal Medicine and of Excellence, University of Palermo, 90127 Palermo, Italy. 3. Department of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties (ProMISE), Section of Endocrinology, Diabetology and Metabolism, University of Palermo, 90127 Palermo, Italy.
Abstract
Background and Objectives: The objective of this paper is to compare the visual outcomes and quality of life (QoL) after bilateral ultrathin Descemet's stripping automated endothelial keratoplasty (UT-DSAEK) with bilateral penetrating keratoplasty (PK) for Fuchs' endothelial dystrophy (FED). Materials and Methods: Retrospective comparative cohort study, including 11 patients with FED who underwent bilateral PK and 13 patients with FED who underwent bilateral UT-DSAEK. All patients were already pseudophakic or had undergone a combined cataract procedure. The main outcomes were corrected distance visual acuity (CDVA) corneal higher-order aberrations (HOAs), contrast sensitivity (CS) and quality of life (QoL). Results: The mean follow-up after the second eye surgery was 32.5 ± 10.2 months in PK and 19.6 ± 8.6 months in UT-DSAEK patients. The CDVA in the UT-DSAEK group was significantly better than in the PK one (0.18 ± 0.07 vs. 0.35 ± 0.16 logMAR, p < 0.0001). The mean anterior corneal total HOAs of the central 5 mm were significantly lower in UT-DSAEK eyes than in PK eyes (0.438 ± 0.078 µ and 1.282 ± 0.330 µ respectively, p < 0.0001), whilst the mean posterior total HOAs did not differ between groups (0.196 ± 0.056 µ and 0.231 ± 0.089 µ, respectively, p = 0.253). The CS was lower at 0.75 and 1.5 cycles/degree in P the K group when compared to the DSAEK one (p = 0.008 and 0.005, respectively). The QoL scores by the NEI RQL-42 test exhibited better values in DSAEK patients in 9 out of 13 scales. Conclusion: Our study confirms that UT-DSAEK provides a better visual function in terms of CDVA and CS, together with lower HOAs, when compared to PK. Hence, the vision-related QoL, binocularly evaluated by the NEI RQL-42 items, indicates a higher satisfaction in UT-DSAEK eyes.
Background and Objectives: The objective of this paper is to compare the visual outcomes and quality of life (QoL) after bilateral ultrathin Descemet's stripping automated endothelial keratoplasty (UT-DSAEK) with bilateral penetrating keratoplasty (PK) for Fuchs' endothelial dystrophy (FED). Materials and Methods: Retrospective comparative cohort study, including 11 patients with FED who underwent bilateral PK and 13 patients with FED who underwent bilateral UT-DSAEK. All patients were already pseudophakic or had undergone a combined cataract procedure. The main outcomes were corrected distance visual acuity (CDVA) corneal higher-order aberrations (HOAs), contrast sensitivity (CS) and quality of life (QoL). Results: The mean follow-up after the second eye surgery was 32.5 ± 10.2 months in PK and 19.6 ± 8.6 months in UT-DSAEK patients. The CDVA in the UT-DSAEK group was significantly better than in the PK one (0.18 ± 0.07 vs. 0.35 ± 0.16 logMAR, p < 0.0001). The mean anterior corneal total HOAs of the central 5 mm were significantly lower in UT-DSAEK eyes than in PK eyes (0.438 ± 0.078 µ and 1.282 ± 0.330 µ respectively, p < 0.0001), whilst the mean posterior total HOAs did not differ between groups (0.196 ± 0.056 µ and 0.231 ± 0.089 µ, respectively, p = 0.253). The CS was lower at 0.75 and 1.5 cycles/degree in P the K group when compared to the DSAEK one (p = 0.008 and 0.005, respectively). The QoL scores by the NEI RQL-42 test exhibited better values in DSAEK patients in 9 out of 13 scales. Conclusion: Our study confirms that UT-DSAEK provides a better visual function in terms of CDVA and CS, together with lower HOAs, when compared to PK. Hence, the vision-related QoL, binocularly evaluated by the NEI RQL-42 items, indicates a higher satisfaction in UT-DSAEK eyes.
Authors: Albert Y Cheung; Joshua H Hou; Peter Bedard; Veronique Grimes; Natalie Buckman; Medi Eslani; Edward J Holland Journal: Cornea Date: 2018-05 Impact factor: 2.651
Authors: Irit Bahar; Igor Kaiserman; Eliya Levinger; Wiwan Sansanayudh; Allan R Slomovic; David S Rootman Journal: Cornea Date: 2009-06 Impact factor: 2.651
Authors: Mor M Dickman; Yanny Y Y Cheng; Tos T J M Berendschot; Frank J H M van den Biggelaar; Rudy M M A Nuijts Journal: JAMA Ophthalmol Date: 2013-06 Impact factor: 7.389
Authors: Maximiliano Barrera-Sanchez; Julio C Hernandez-Camarena; Raul E Ruiz-Lozano; Jorge E Valdez-Garcia; Alejandro Rodriguez-Garcia Journal: Int Ophthalmol Date: 2021-11-07 Impact factor: 2.031