Literature DB >> 23579576

Effects of graft thickness and asymmetry on visual gain and aberrations after descemet stripping automated endothelial keratoplasty.

Mor M Dickman1, Yanny Y Y Cheng, Tos T J M Berendschot, Frank J H M van den Biggelaar, Rudy M M A Nuijts.   

Abstract

IMPORTANCE: Understanding the contribution of graft thickness and asymmetry to visual gain and posterior corneal (PC) higher-order aberrations (HOAs) may assist optimizing visual outcomes after Descemet stripping automated endothelial keratoplasty (DSAEK).
OBJECTIVE: To investigate the effects of graft thickness and asymmetry on visual gain and aberrations after DSAEK.
DESIGN: Retrospective analysis of an interventional case series of eyes undergoing DSAEK. Visual gain was defined as the difference between preoperative and 6-month postoperative best-corrected visual acuity in logMAR equivalents. Graft thickness was measured by anterior-segment optical coherence tomography. Corneal topography and HOAs were measured by Scheimpflug imaging. Raw posterior corneal (PC) elevation data were exported and fitted against a best-fitted sphere, providing a measure of donor lenticule asymmetry. Correlation analysis was performed among visual gain, graft thickness, graft asymmetry, and PC HOAs.
SETTING: University Eye Clinic Maastricht. PARTICIPANTS: Seventy-nine eyes with corneal endothelial dysfunction. EXPOSURE: All patients underwent DSAEK [corrected]. MAIN OUTCOMES AND MEASURES: Visual gain, graft thickness, graft asymmetry, and PC HOAs.
RESULTS: Mean best-corrected visual acuity improved from 0.63 logMAR equivalents preoperatively to 0.25 logMAR equivalents postoperatively (P < .001). Mean (SD) graft thickness of the series was 97 (25) (range, 39-145) μm. After excluding patients with vision-limiting comorbidities, visual gain significantly correlated with graft thickness (r = -0.35 [P = .02]). This correlation was strongest in patients with pseudophakic bullous keratopathy (r = -0.62 [P = .01]). Graft thickness significantly correlated with graft asymmetry in the 4- and 6-mm zones (r = 0.32 [P = .007] and r = 0.32 [P = .006], respectively), which in turn correlated with all but spherical PC HOAs. CONCLUSIONS AND RELEVANCE: After DSAEK, visual gain shows a significant correlation with graft thickness in patients without vision-limiting comorbidities. This relationship is strongest in patients with pseudophakic bullous keratopathy. Graft thickness also correlates with graft asymmetry, which in turn correlates with all but spherical PC HOAs. These findings may assist surgeons in choosing DSAEK graft thickness and shape, particularly in eyes without vision-limiting comorbidities. Further randomized trials are needed to investigate the relationship between graft thickness and visual gain after DSAEK.

Entities:  

Mesh:

Year:  2013        PMID: 23579576     DOI: 10.1001/jamaophthalmol.2013.73

Source DB:  PubMed          Journal:  JAMA Ophthalmol        ISSN: 2168-6165            Impact factor:   7.389


  15 in total

1.  Corneal Higher-Order Aberrations in Descemet Membrane Endothelial Keratoplasty versus Ultrathin DSAEK in the Descemet Endothelial Thickness Comparison Trial: A Randomized Clinical Trial.

Authors:  Matthew J Duggan; Jennifer Rose-Nussbaumer; Charles C Lin; Ariana Austin; Paula C Labadzinzki; Winston D Chamberlain
Journal:  Ophthalmology       Date:  2019-02-16       Impact factor: 12.079

2.  Effects of corneal irregular astigmatism on visual acuity after conventional and femtosecond laser-assisted Descemet's stripping automated endothelial keratoplasty.

Authors:  Daisuke Tomida; Takefumi Yamaguchi; Akiko Ogawa; Yumiko Hirayama; Seika Shimazaki-Den; Yoshiyuki Satake; Jun Shimazaki
Journal:  Jpn J Ophthalmol       Date:  2015-06-02       Impact factor: 2.447

3.  Profiles of intraocular higher-order aberrations in healthy phakic eyes: prospective cross-sectional study.

Authors:  Jiaqing Zhang; Guangming Jin; Ling Jin; Xiaoting Ruan; Xiaoxun Gu; Wei Wang; Xiaoyun Chen; Lanhua Wang; Ye Dai; Zhenzhen Liu; Lixia Luo; Yizhi Liu
Journal:  Ann Transl Med       Date:  2020-07

4.  Thinning rate over 24 months in ultrathin DSAEK.

Authors:  Matthew T Fenech; Giulia Coco; Luca Pagano; Kunal A Gadhvi; Mitchell Titley; Hannah J Levis; Mohit Parekh; Stephen B Kaye; Vito Romano
Journal:  Eye (Lond)       Date:  2022-03-15       Impact factor: 4.456

5.  Evaluation of factors affecting visual acuity after Descemet stripping automated endothelial keratoplasty.

Authors:  Shiro Amano; Akira Setogawa; Kenji Inoue
Journal:  Jpn J Ophthalmol       Date:  2016-12-10       Impact factor: 2.447

6.  Bilateral Ultrathin Descemet's Stripping Automated Endothelial Keratoplasty vs. Bilateral Penetrating Keratoplasty in Fuchs' Dystrophy: Corneal Higher-Order Aberrations, Contrast Sensitivity and Quality of Life.

Authors:  Massimo Castellucci; Costanza Novara; Alessandra Casuccio; Giovannni Cillino; Carla Giordano; Valentina Failla; Vincenza Bonfiglio; Maria Vadalà; Salvatore Cillino
Journal:  Medicina (Kaunas)       Date:  2021-02-03       Impact factor: 2.430

7.  Lower Corneal Haze and Aberrations in Descemet Membrane Endothelial Keratoplasty Versus Descemet Stripping Automated Endothelial Keratoplasty in Fellow Eyes for Fuchs Endothelial Corneal Dystrophy.

Authors:  William H Waldrop; Matthew J Gillings; Danielle M Robertson; W Matthew Petroll; V Vinod Mootha
Journal:  Cornea       Date:  2020-10       Impact factor: 3.152

8.  Effect of Intraocular Forward Scattering and Corneal Higher-Order Aberrations on Visual Acuity after Descemet's Stripping Automated Endothelial Keratoplasty.

Authors:  Kazutaka Kamiya; Hitomi Asato; Kimiya Shimizu; Hidenaga Kobashi; Akihito Igarashi
Journal:  PLoS One       Date:  2015-06-19       Impact factor: 3.240

9.  Visual Outcomes of Ultrathin-Descemet Stripping Endothelial Keratoplasty versus Descemet Stripping Endothelial Keratoplasty.

Authors:  Konstantinos Droutsas; Myrsini Petrelli; Dimitrios Miltsakakis; Konstantinos Andreanos; Anastasia Karagianni; Apostolos Lazaridis; Chrysanthi Koutsandrea; George Kymionis
Journal:  J Ophthalmol       Date:  2018-11-01       Impact factor: 1.909

10.  Descemet stripping automated endothelial keratoplasty in Fuchs' corneal endothelial dystrophy: anterior segment optical coherence tomography and in vivo confocal microscopy analysis.

Authors:  Rita Mencucci; Eleonora Favuzza; Ruggero Tartaro; Massimo Busin; Gianni Virgili
Journal:  BMC Ophthalmol       Date:  2015-08-08       Impact factor: 2.209

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.