Literature DB >> 33524638

Defocus-dependent Thon-ring fading.

Robert M Glaeser1, Wim J H Hagen2, Bong-Gyoon Han3, Richard Henderson4, Greg McMullan4, Christopher J Russo4.   

Abstract

The brightness of modern Schottky field-emission guns can produce electron beams that have very high spatial coherence, especially for the weak-illumination conditions that are used for single-particle electron cryo-microscopy in structural biology. Even so, many users have observed defocus-dependent Thon-ring fading that has led them to restrict their data collection strategy to imaging with relatively small defocus values. In this paper, we reproduce the observation of defocus-dependent Thon-ring fading and produce a quantitative analysis and clear explanation of its causes. We demonstrate that a major cause is the delocalization of high-resolution Fourier components outside the field of view of the camera. We also show that, to correctly characterize the phenomenon, it is important to make a correction for linear magnification anisotropy. Even when the anisotropy is quite small, it is present at all defocus values before circular averaging of the Thon rings, as is also true before merging data from particles in many orientations. Under the conditions used in this paper, which are typical of those used in single-particle electron cryomicroscopy, fading of the Thon rings due to source coherence is negligible. The principal conclusion is that much higher values of defocus can be used to record images than is currently thought to be possible, keeping in mind that the above-mentioned delocalization of Fourier components will ultimately become a limitation. This increased understanding should give electron microscopists the confidence to use higher amounts of defocus to allow, for example, better visibility of their particles and Ewald sphere correction.
Copyright © 2021 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Delocalization; High defocus; Spatial coherence

Mesh:

Substances:

Year:  2021        PMID: 33524638      PMCID: PMC7897310          DOI: 10.1016/j.ultramic.2021.113213

Source DB:  PubMed          Journal:  Ultramicroscopy        ISSN: 0304-3991            Impact factor:   2.689


  9 in total

1.  Fully automatic stitching and distortion correction of transmission electron microscope images.

Authors:  Verena Kaynig; Bernd Fischer; Elisabeth Müller; Joachim M Buhmann
Journal:  J Struct Biol       Date:  2010-05-05       Impact factor: 2.867

Review 2.  Precise beam-tilt alignment and collimation are required to minimize the phase error associated with coma in high-resolution cryo-EM.

Authors:  Robert M Glaeser; Dieter Typke; Peter C Tiemeijer; James Pulokas; Anchi Cheng
Journal:  J Struct Biol       Date:  2010-12-21       Impact factor: 2.867

3.  Restoration of weak phase-contrast images recorded with a high degree of defocus: the "twin image" problem associated with CTF correction.

Authors:  Kenneth H Downing; Robert M Glaeser
Journal:  Ultramicroscopy       Date:  2008-04-03       Impact factor: 2.689

Review 4.  MRC image processing programs.

Authors:  R A Crowther; R Henderson; J M Smith
Journal:  J Struct Biol       Date:  1996 Jan-Feb       Impact factor: 2.867

5.  Electron Source Brightness and Illumination Semi-Angle Distribution Measurement in a Transmission Electron Microscope.

Authors:  Felix Börrnert; Julian Renner; Ute Kaiser
Journal:  Microsc Microanal       Date:  2018-05-21       Impact factor: 4.127

Review 6.  Single-Particle Cryo-EM at Crystallographic Resolution.

Authors:  Yifan Cheng
Journal:  Cell       Date:  2015-04-23       Impact factor: 41.582

7.  Microscopic charge fluctuations cause minimal contrast loss in cryoEM.

Authors:  Christopher J Russo; Richard Henderson
Journal:  Ultramicroscopy       Date:  2018-01-31       Impact factor: 2.689

8.  Ewald sphere correction using a single side-band image processing algorithm.

Authors:  Christopher J Russo; Richard Henderson
Journal:  Ultramicroscopy       Date:  2018-01-12       Impact factor: 2.689

9.  Low-dose phase retrieval of biological specimens using cryo-electron ptychography.

Authors:  Liqi Zhou; Jingdong Song; Judy S Kim; Xudong Pei; Chen Huang; Mark Boyce; Luiza Mendonça; Daniel Clare; Alistair Siebert; Christopher S Allen; Emanuela Liberti; David Stuart; Xiaoqing Pan; Peter D Nellist; Peijun Zhang; Angus I Kirkland; Peng Wang
Journal:  Nat Commun       Date:  2020-06-02       Impact factor: 17.694

  9 in total
  4 in total

Review 1.  Emerging Themes in CryoEM─Single Particle Analysis Image Processing.

Authors:  Jose Luis Vilas; Jose Maria Carazo; Carlos Oscar S Sorzano
Journal:  Chem Rev       Date:  2022-07-04       Impact factor: 72.087

2.  Imaging biological macromolecules in thick specimens: The role of inelastic scattering in cryoEM.

Authors:  Joshua L Dickerson; Peng-Han Lu; Dilyan Hristov; Rafal E Dunin-Borkowski; Christopher J Russo
Journal:  Ultramicroscopy       Date:  2022-03-19       Impact factor: 2.994

3.  Routine sub-2.5 Å cryo-EM structure determination of GPCRs.

Authors:  Radostin Danev; Matthew Belousoff; Yi-Lynn Liang; Xin Zhang; Fabian Eisenstein; Denise Wootten; Patrick M Sexton
Journal:  Nat Commun       Date:  2021-07-15       Impact factor: 14.919

4.  2.5 Å-resolution structure of human CDK-activating kinase bound to the clinical inhibitor ICEC0942.

Authors:  Basil J Greber; Jonathan Remis; Simak Ali; Eva Nogales
Journal:  Biophys J       Date:  2021-01-19       Impact factor: 4.033

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.