Restoration of weak phase-contrast images recorded with a high degree of defocus: the "twin image" problem associated with CTF correction.

Kenneth H Downing1, Robert M Glaeser.   

Abstract

Relatively large values of objective-lens defocus must normally be used to produce detectable levels of image contrast for unstained biological specimens, which are generally weak phase objects. As a result, a subsequent restoration operation must be used to correct for oscillations in the contrast transfer function (CTF) at higher resolution. Currently used methods of CTF correction assume the ideal case in which Friedel mates in the scattered wave have contributed pairs of Fourier components that overlap with one another in the image plane. This "ideal" situation may be only poorly satisfied, or not satisfied at all, as the particle size gets smaller, the defocus value gets larger, and the resolution gets higher. We have therefore investigated whether currently used methods of CTF correction are also effective in restoring the single-sideband image information that becomes displaced (delocalized) by half (or more) the diameter of a particle of finite size. Computer simulations are used to show that restoration either by "phase flipping" or by multiplying by the CTF recovers only about half of the delocalized information. The other half of the delocalized information goes into a doubly defocused "twin" image of the type produced during optical reconstruction of an in-line hologram. Restoration with a Wiener filter is effective in recovering the delocalized information only when the signal-to-noise ratio (S/N) is orders of magnitude higher than that which exists in low-dose images of biological specimens, in which case the Wiener filter approaches division by the CTF (i.e. the formal inverse). For realistic values of the S/N, however, the "twin image" problem seen with a Wiener filter is very similar to that seen when either phase flipping or multiplying by the CTF is used for restoration. The results of these simulations suggest that CTF correction is a poor alternative to using a Zernike-type phase plate when imaging biological specimens, in which case the images can be recorded in a close-to-focus condition, and delocalization of high-resolution information is thus minimized.

Entities:  

Mesh:

Year:  2008        PMID: 18508199      PMCID: PMC2694513          DOI: 10.1016/j.ultramic.2008.03.004

Source DB:  PubMed          Journal:  Ultramicroscopy        ISSN: 0304-3991            Impact factor:   2.689


  12 in total

1.  Structure determination of tubular crystals of membrane proteins. III. Solvent flattening.

Authors:  K Yonekura; C Toyoshima
Journal:  Ultramicroscopy       Date:  2000-07       Impact factor: 2.689

2.  Transmission electron microscopy with Zernike phase plate.

Authors:  R Danev; K Nagayama
Journal:  Ultramicroscopy       Date:  2001-09       Impact factor: 2.689

3.  How I discovered phase contrast.

Authors:  F ZERNIKE
Journal:  Science       Date:  1955-03-11       Impact factor: 47.728

4.  Measurement of focus and spherical aberration of an electron microscope objective lens.

Authors:  T F Budinger; R M Glaeser
Journal:  Ultramicroscopy       Date:  1976-12       Impact factor: 2.689

5.  Structural basis for the control of translation initiation during stress.

Authors:  Antón Vila-Sanjurjo; Barbara-S Schuwirth; Cathy W Hau; Jamie H D Cate
Journal:  Nat Struct Mol Biol       Date:  2004-10-24       Impact factor: 15.369

6.  Bsoft: image processing and molecular modeling for electron microscopy.

Authors:  J Bernard Heymann; David M Belnap
Journal:  J Struct Biol       Date:  2006-06-28       Impact factor: 2.867

7.  SPIRE: the SPIDER reconstruction engine.

Authors:  William T Baxter; ArDean Leith; Joachim Frank
Journal:  J Struct Biol       Date:  2006-08-25       Impact factor: 2.867

8.  A new microscopic principle.

Authors:  D GABOR
Journal:  Nature       Date:  1948-05-15       Impact factor: 49.962

9.  Holography, 1948--1971.

Authors:  D Gabor
Journal:  Science       Date:  1972-07-28       Impact factor: 47.728

10.  Practical factors affecting the performance of a thin-film phase plate for transmission electron microscopy.

Authors:  Radostin Danev; Robert M Glaeser; Kuniaki Nagayama
Journal:  Ultramicroscopy       Date:  2008-12-11       Impact factor: 2.689

View more
  15 in total

Review 1.  Invited review article: Methods for imaging weak-phase objects in electron microscopy.

Authors:  Robert M Glaeser
Journal:  Rev Sci Instrum       Date:  2013-11       Impact factor: 1.523

2.  APPLE picker: Automatic particle picking, a low-effort cryo-EM framework.

Authors:  Ayelet Heimowitz; Joakim Andén; Amit Singer
Journal:  J Struct Biol       Date:  2018-08-19       Impact factor: 2.867

3.  Design of a hybrid double-sideband/single-sideband (schlieren) objective aperture suitable for electron microscopy.

Authors:  Bart Buijsse; Frank M H M van Laarhoven; Andreas K Schmid; Rossana Cambie; Stefano Cabrini; Jian Jin; Robert M Glaeser
Journal:  Ultramicroscopy       Date:  2011-10-04       Impact factor: 2.689

4.  Practical factors affecting the performance of a thin-film phase plate for transmission electron microscopy.

Authors:  Radostin Danev; Robert M Glaeser; Kuniaki Nagayama
Journal:  Ultramicroscopy       Date:  2008-12-11       Impact factor: 2.689

5.  An adaptation of the Wiener filter suitable for analyzing images of isolated single particles.

Authors:  Charles V Sindelar; Nikolaus Grigorieff
Journal:  J Struct Biol       Date:  2011-07-02       Impact factor: 2.867

6.  Protocols for Processing and Interpreting cryoEM Data Using Bsoft: A Case Study of the Retinal Adhesion Protein, Retinoschisin.

Authors:  J Bernard Heymann
Journal:  Bio Protoc       Date:  2020-01-20

7.  Defocus-dependent Thon-ring fading.

Authors:  Robert M Glaeser; Wim J H Hagen; Bong-Gyoon Han; Richard Henderson; Greg McMullan; Christopher J Russo
Journal:  Ultramicroscopy       Date:  2021-01-21       Impact factor: 2.689

8.  Efficient linear phase contrast in scanning transmission electron microscopy with matched illumination and detector interferometry.

Authors:  Colin Ophus; Jim Ciston; Jordan Pierce; Tyler R Harvey; Jordan Chess; Benjamin J McMorran; Cory Czarnik; Harald H Rose; Peter Ercius
Journal:  Nat Commun       Date:  2016-02-29       Impact factor: 14.919

9.  Two classes of protective antibodies against Pseudorabies virus variant glycoprotein B: Implications for vaccine design.

Authors:  Xiangdong Li; Fanli Yang; Xule Hu; Feifei Tan; Jianxun Qi; Ruchao Peng; Min Wang; Yan Chai; Liying Hao; Junhua Deng; Chenyu Bai; Juan Wang; Hao Song; Shuguang Tan; Guangwen Lu; George F Gao; Yi Shi; Kegong Tian
Journal:  PLoS Pathog       Date:  2017-12-20       Impact factor: 6.823

10.  Microscopic charge fluctuations cause minimal contrast loss in cryoEM.

Authors:  Christopher J Russo; Richard Henderson
Journal:  Ultramicroscopy       Date:  2018-01-31       Impact factor: 2.689

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.