Literature DB >> 33498652

Pulp Vitality Testing with a Developed Universal Pulse Oximeter Probe Holder.

Živilė Grabliauskienė1, Roberta Zamaliauskienė1, Greta Lodienė1.   

Abstract

Background and Objectives An accurate determination of the pulp status is relevant for a proper endodontic diagnosis.
Objectives: The aim was to develop a universal pulse oximeter probe holder for measuring the oxygen saturation and to evaluate the use of pulse oximetry as a test for pulp vitality, by comparing the levels of oxygen saturation in the index finger and in the healthy dental pulp. Materials and Methods The universal holder was designed with software and printed with a 3D printer. The study was carried out on 128 healthy teeth. They were divided into eight groups according to tooth type. Ten root canal treated teeth served as a negative control group. For each patient, a pulse oximeter was first applied on the tooth followed by the index finger. The significance level (α) was set at 0.05.
Results: The developed and manufactured universal pulse oximeter probe holder was suitable to measure the pulp vitality of all types of teeth. The handle allowed for holding the pulse oximeter on the tooth in parallel, firmly and securely. Significantly higher oxygen saturation was observed in the index finger (97.22%) compared to the dental pulp (93.17%) (p < 0.001). No correlation was observed between the maxillary teeth and index finger oxygen saturation values (r = 0.05, p = 0.72), whereas, between the mandibular teeth and index finger, a positive correlation was detected (r = 0.29, p = 0.02). There were no significant differences in the pulp oxygen saturation values between different teeth groups.
Conclusion: The newly developed universal pulse oximeter probe holder is an effective device for pulp vitality testing.

Entities:  

Keywords:  CAD; clinical outcomes; clinical practice guidelines; clinical studies/trials; diagnostic systems; endodontics; pulp vitality tests; pulse oximeter

Mesh:

Substances:

Year:  2021        PMID: 33498652      PMCID: PMC7912332          DOI: 10.3390/medicina57020101

Source DB:  PubMed          Journal:  Medicina (Kaunas)        ISSN: 1010-660X            Impact factor:   2.430


  30 in total

1.  Effect of aging on the human pulp.

Authors:  S Bernick; C Nedelman
Journal:  J Endod       Date:  1975-03       Impact factor: 4.171

2.  Assessment of the efficacy of an indigeniously developed pulse oximeter dental sensor holder for pulp vitality testing.

Authors:  V Gopi Krishna; D Kandaswamy; Tina Gupta
Journal:  Indian J Dent Res       Date:  2006 Jul-Sep

3.  Comparison of electrical, thermal, and pulse oximetry methods for assessing pulp vitality in recently traumatized teeth.

Authors:  Velayutham Gopikrishna; Kush Tinagupta; Deivanayagam Kandaswamy
Journal:  J Endod       Date:  2007-03-12       Impact factor: 4.171

4.  Evaluation of efficacy of a new custom-made pulse oximeter dental probe in comparison with the electrical and thermal tests for assessing pulp vitality.

Authors:  Velayutham Gopikrishna; Kush Tinagupta; Deivanayagam Kandaswamy
Journal:  J Endod       Date:  2007-02-23       Impact factor: 4.171

5.  Evaluation of a pulse oximeter and customized probe for pulp vitality testing.

Authors:  R S Kahan; K Gulabivala; M Snook; D J Setchell
Journal:  J Endod       Date:  1996-03       Impact factor: 4.171

6.  Pulse oximetry evaluation of vitality in primary and immature permanent teeth.

Authors:  C Goho
Journal:  Pediatr Dent       Date:  1999 Mar-Apr       Impact factor: 1.874

7.  Oxygen Saturation in the Dental Pulp of Maxillary Premolars in Different Age Groups - Part 1.

Authors:  Carlos Estrela; Giuliano C Serpa; Ana Helena G Alencar; Kely F Bruno; Fernando B Barletta; Wilson T Felippe; Cyntia R A Estrela; João B Souza
Journal:  Braz Dent J       Date:  2017 Jul-Sep

8.  Effect of gingiva on laser doppler pulpal blood flow measurements.

Authors:  Kerem Engin Akpinar; Kürşat Er; Serkan Polat; Nilüfer Tülin Polat
Journal:  J Endod       Date:  2004-03       Impact factor: 4.171

9.  Determination of pulp vitality in vivo with pulse oximetry.

Authors:  E Calil; C L Caldeira; G Gavini; E M Lemos
Journal:  Int Endod J       Date:  2008-06-28       Impact factor: 5.264

10.  Assessment of Pulp Oxygen Saturation Levels by Pulse Oximetry for Pulpal Diseases -A Diagnostic Study.

Authors:  Bander Anusha; Koppolu Madhusudhana; Suneel Kumar Chinni; Yelloji Paramesh
Journal:  J Clin Diagn Res       Date:  2017-09-01
View more
  3 in total

Review 1.  A Diagnostic Insight of Dental Pulp Testing Methods in Pediatric Dentistry.

Authors:  Andreea Igna; Doina Mircioagă; Marius Boariu; Ștefan-Ioan Stratul
Journal:  Medicina (Kaunas)       Date:  2022-05-16       Impact factor: 2.948

2.  Oxygen Saturation in Primary Teeth of Individuals With Sickle Cell Disease and Sickle Cell Trait.

Authors:  Evarist Mulyahela Wilson; Irene Kida Minja; Ferdinand Mabula Machibya; Agnes Jonathan; Julie Makani; Paschal Ruggajo; Emmanuel Balandya
Journal:  J Blood Med       Date:  2022-07-22

3.  Assessment of Pulpal Status in Primary Teeth Following Direct Pulp Capping in an Experimental Canine Model.

Authors:  Andreea Igna; Cornel Igna; Mariana Ioana Miron; Larisa Schuszler; Roxana Dascălu; Mihaela Moldovan; Adrian Aristide Voicu; Carmen Darinca Todea; Marius Boariu; Maria-Alexandra Mârțu; Ștefan-Ioan Stratul
Journal:  Diagnostics (Basel)       Date:  2022-08-21
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.