Assessment of the efficacy of an indigeniously developed pulse oximeter dental sensor holder for pulp vitality testing.

V Gopi Krishna1, D Kandaswamy, Tina Gupta.   

Abstract

Current routine methods of assessment of pulp vitality rely on stimulation of nerve fibres and give no direct indication of blood flow within the pulp. Pulse oximeter is a proven, atraumatic method of measuring vascular status, by evaluating oxygen saturation. This study explores the use of customized dental pulse oximeter sensor holder to assess pulpal vascular oxygen saturation in permanent teeth. Pulse oximeter readily differentiated between known vital and nonvital teeth. Vital teeth consistently provided oxygen saturation values that were lower than the values recorded on the patient's fingers. Pulse oximeter is an accurate, atraumatic clinical alternative to the present electrical and thermal methods of assessing pulp vitality in teeth.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17176825     DOI: 10.4103/0970-9290.29880

Source DB:  PubMed          Journal:  Indian J Dent Res        ISSN: 0970-9290


  5 in total

1.  Reference values for pulp oxygen saturation as a diagnostic tool in endodontics: a systematic review and meta-analysis.

Authors:  Paula Lambert; Sergio Augusto Quevedo Miguens; Caroline Solda; Juliana Tomaz Sganzerla; Leandro Azambuja Reichert; Carlos Estrela; Fernando Branco Barletta
Journal:  Restor Dent Endod       Date:  2020-10-05

2.  Efficiency of new custom-made pulse oximeter sensor holder in assessment of actual pulp status.

Authors:  Krishnamachari Janani; P Ajitha; Raghu Sandhya; Haripriya Subbaiyan; Jerry Jose
Journal:  J Family Med Prim Care       Date:  2020-07-30

3.  Determining the effect of implant surgery on blood oxygen saturation of the adjacent tooth.

Authors:  Nasser Kaviani; Mohammad Shahaboyi; Arezoo Khabazian
Journal:  Dent Res J (Isfahan)       Date:  2012-07

Review 4.  Comparative Study of Pulp Vitality in Primary and Young Permanent Molars in Human Children with Pulse Oximeter and Electric Pulp Tester.

Authors:  Prinka Shahi; P B Sood; Arun Sharma; Manish Madan; Nishat Shahi; Geetanjali Gandhi
Journal:  Int J Clin Pediatr Dent       Date:  2015-08-11

5.  Pulp Vitality Testing with a Developed Universal Pulse Oximeter Probe Holder.

Authors:  Živilė Grabliauskienė; Roberta Zamaliauskienė; Greta Lodienė
Journal:  Medicina (Kaunas)       Date:  2021-01-23       Impact factor: 2.430