Literature DB >> 33494809

Smartphone / smartwatch-based cuffless blood pressure measurement : a position paper from the Korean Society of Hypertension.

Hae Young Lee1, Dong-Ju Lee1, Jongmo Seo2, Sang-Hyun Ihm3, Kwang-Il Kim4, Eun Joo Cho5, Hyeon Chang Kim6, Jinho Shin7, Sungha Park8, Il-Suk Sohn9, Wook-Jin Chung10, Sung Kee Ryu11, Ki Chul Sung12, Juhan Kim13, Dae-Hee Kim14, Wook Bum Pyun15.   

Abstract

Smartphone technology has spread rapidly around the globe. According to a report released by the Korea Information Society Development Institute, about 95% of Koreans aged more than 30 years old owned smartphones. Recently, blood pressure (BP) measurement using a photoplethysmography-based smartphone algorithm paired with the smartwatch is continuously evolving. In this document, the Korean Society of Hypertension intends to remark the current results of smartphone / smartwatch-based BP measurement and recommend optimal BP measurement methods using a smartphone device. We aim to increase the likelihood of success in implementing these new technologies into improved hypertension awareness, diagnosis, and control.

Entities:  

Keywords:  Blood pressure; Hypertension; Measurement; Plethysmography; Smartphone

Year:  2021        PMID: 33494809      PMCID: PMC7831256          DOI: 10.1186/s40885-020-00158-8

Source DB:  PubMed          Journal:  Clin Hypertens        ISSN: 2056-5909


  28 in total

1.  Self-measurement of blood pressure at home reduces the need for antihypertensive drugs: a randomized, controlled trial.

Authors:  Willem J Verberk; Abraham A Kroon; Jacques W M Lenders; Alfons G H Kessels; Gert A van Montfrans; Andries J Smit; Paul-Hugo M van der Kuy; Patricia J Nelemans; Roger J M W Rennenberg; Diederick E Grobbee; Frank W Beltman; Manuela A Joore; Daniëlle E M Brunenberg; Carmen Dirksen; Theo Thien; Peter W de Leeuw
Journal:  Hypertension       Date:  2007-10-15       Impact factor: 10.190

2.  Data-driven estimation of blood pressure using photoplethysmographic signals.

Authors:  Peter Wittek
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2016-08

3.  Cuffless differential blood pressure estimation using smart phones.

Authors:  Vikram Chandrasekaran; Ram Dantu; Srikanth Jonnada; Shanti Thiyagaraja; Kalyan Pathapati Subbu
Journal:  IEEE Trans Biomed Eng       Date:  2012-08-01       Impact factor: 4.538

4.  Smartphone-Based Blood Pressure Measurement Using Transdermal Optical Imaging Technology.

Authors:  Hong Luo; Deye Yang; Andrew Barszczyk; Naresh Vempala; Jing Wei; Si Jia Wu; Paul Pu Zheng; Genyue Fu; Kang Lee; Zhong-Ping Feng
Journal:  Circ Cardiovasc Imaging       Date:  2019-08-06       Impact factor: 7.792

Review 5.  Peripheral vascular effects on auscultatory blood pressure measurement.

Authors:  S Y Rabbany; G M Drzewiecki; A Noordergraaf
Journal:  J Clin Monit       Date:  1993-01

6.  Comparison of smartphone application-based vital sign monitors without external hardware versus those used in clinical practice: a prospective trial.

Authors:  John C Alexander; Abu Minhajuddin; Girish P Joshi
Journal:  J Clin Monit Comput       Date:  2016-05-12       Impact factor: 2.502

Review 7.  Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association.

Authors:  Paul Muntner; Daichi Shimbo; Robert M Carey; Jeanne B Charleston; Trudy Gaillard; Sanjay Misra; Martin G Myers; Gbenga Ogedegbe; Joseph E Schwartz; Raymond R Townsend; Elaine M Urbina; Anthony J Viera; William B White; Jackson T Wright
Journal:  Hypertension       Date:  2019-05       Impact factor: 10.190

8.  The systolic blood pressure difference between arms and cardiovascular disease in the Framingham Heart Study.

Authors:  Ido Weinberg; Philimon Gona; Christopher J O'Donnell; Michael R Jaff; Joanne M Murabito
Journal:  Am J Med       Date:  2013-11-25       Impact factor: 4.965

9.  Blood pressure control by home monitoring: meta-analysis of randomised trials.

Authors:  Francesco P Cappuccio; Sally M Kerry; Lindsay Forbes; Anna Donald
Journal:  BMJ       Date:  2004-06-11

10.  2018 Korean Society of Hypertension Guidelines for the management of hypertension: part II-diagnosis and treatment of hypertension.

Authors:  Hae-Young Lee; Jinho Shin; Gheun-Ho Kim; Sungha Park; Sang-Hyun Ihm; Hyun Chang Kim; Kwang-Il Kim; Ju Han Kim; Jang Hoon Lee; Jong-Moo Park; Wook Bum Pyun; Shung Chull Chae
Journal:  Clin Hypertens       Date:  2019-08-01
View more
  8 in total

Review 1.  Evaluation of the Accuracy of Cuffless Blood Pressure Measurement Devices: Challenges and Proposals.

Authors:  Ramakrishna Mukkamala; Mohammad Yavarimanesh; Keerthana Natarajan; Jin-Oh Hahn; Konstantinos G Kyriakoulis; Alberto P Avolio; George S Stergiou
Journal:  Hypertension       Date:  2021-09-13       Impact factor: 10.190

2.  Ten-year trends of hypertension treatment and control rate in Korea.

Authors:  Kwang-Il Kim; Eunjeong Ji; Jung-Yeon Choi; Sun-Wook Kim; Soyeon Ahn; Cheol-Ho Kim
Journal:  Sci Rep       Date:  2021-03-26       Impact factor: 4.379

3.  Highly integrated watch for noninvasive continual glucose monitoring.

Authors:  Tianrui Chang; Hu Li; Nianrong Zhang; Xinran Jiang; Xinge Yu; Qingde Yang; Zhiyuan Jin; Hua Meng; Lingqian Chang
Journal:  Microsyst Nanoeng       Date:  2022-02-23       Impact factor: 7.127

4.  Smartwatch-Based Blood Pressure Measurement Demonstrates Insufficient Accuracy.

Authors:  Maarten Falter; Martijn Scherrenberg; Karen Driesen; Zoë Pieters; Toshiki Kaihara; Linqi Xu; Enrico Gianluca Caiani; Paolo Castiglioni; Andrea Faini; Gianfranco Parati; Paul Dendale
Journal:  Front Cardiovasc Med       Date:  2022-07-11

Review 5.  Home blood pressure monitoring: a position statement from the Korean Society of Hypertension Home Blood Pressure Forum.

Authors:  Sang-Hyun Ihm; Jae-Hyeong Park; Jang Young Kim; Ju-Han Kim; Kwang-Il Kim; Eun Mi Lee; Hae-Young Lee; Sungha Park; Jinho Shin; Cheol-Ho Kim
Journal:  Clin Hypertens       Date:  2022-10-01

6.  Validation of Blood Pressure Measurement Using a Smartwatch in Patients With Parkinson's Disease.

Authors:  Jong Hyeon Ahn; Joomee Song; Inyoung Choi; Jinyoung Youn; Jin Whan Cho
Journal:  Front Neurol       Date:  2021-06-29       Impact factor: 4.003

7.  Smartphone based blood pressure measurement: accuracy of the OptiBP mobile application according to the AAMI/ESH/ISO universal validation protocol.

Authors:  Jean Degott; Arlene Ghajarzadeh-Wurzner; Gregory Hofmann; Martin Proença; Guillaume Bonnier; Alia Lemkaddem; Mathieu Lemay; Urvan Christen; Jean-François Knebel; Virginie Durgnat; Michel Burnier; Gregoire Wuerzner; Patrick Schoettker
Journal:  Blood Press Monit       Date:  2021-12-01       Impact factor: 1.430

8.  Comparability of a Blood-Pressure-Monitoring Smartphone Application with Conventional Measurements-A Pilot Study.

Authors:  Annina S Vischer; Jana Rosania; Thenral Socrates; Christina Blaschke; Jens Eckstein; Yara-Maria Proust; Guillaume Bonnier; Martin Proença; Mathieu Lemay; Thilo Burkard
Journal:  Diagnostics (Basel)       Date:  2022-03-19
  8 in total