Literature DB >> 8463815

Peripheral vascular effects on auscultatory blood pressure measurement.

S Y Rabbany1, G M Drzewiecki, A Noordergraaf.   

Abstract

Experiments were conducted to examine the accuracy of the conventional auscultatory method of blood pressure measurement. The influence of the physiologic state of the vascular system in the forearm distal to the site of Korotkoff sound recording and its impact on the precision of the measured blood pressure is discussed. The peripheral resistance in the arm distal to the cuff was changed noninvasively by heating and cooling effects and by induction of reactive hyperemia. All interventions were preceded by an investigation of their effect on central blood pressure to distinguish local effects from changes in central blood pressure. These interventions were sufficiently moderate to make their effect on central blood pressure, recorded in the other arm, statistically insignificant (i.e., changes in systolic [p < 0.3] and diastolic [p < 0.02]). Nevertheless, such alterations were found to modify the amplitude of the Korotkoff sound, which can manifest itself as an apparent change in arterial blood pressure that is readily discerned by the human ear. The increase in diastolic pressure for the cooling experiments was statistically significant (p < 0.001). Moreover, both measured systolic (p < 0.004) and diastolic (p < 0.001) pressure decreases during the reactive hyperemia experiments were statistically significant. The findings demonstrate that alteration in vascular state generates perplexing changes in blood pressure, hence confirming experimental observations by earlier investigators as well as predictions by our model studies.

Entities:  

Mesh:

Year:  1993        PMID: 8463815     DOI: 10.1007/bf01627631

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  21 in total

1.  The significance of the intermediate Korotkoff sounds.

Authors:  S RODBARD
Journal:  Circulation       Date:  1953-10       Impact factor: 29.690

2.  The Korotkoff sound.

Authors:  G M Drzewiecki; J Melbin; A Noordergraaf
Journal:  Ann Biomed Eng       Date:  1989       Impact factor: 3.934

3.  Blood pressure measurement in shock. Mechanism of inaccuracy in ausculatory and palpatory methods.

Authors:  J N Cohn
Journal:  JAMA       Date:  1967-03-27       Impact factor: 56.272

4.  How to test stethoscopes.

Authors:  P Y Ertel; M Lawrence; W Song
Journal:  Med Res Eng       Date:  1969 Jan-Feb

5.  Essential hypertension in the elderly: haemodynamics, intravascular volume, plasma renin activity, and circulating catecholamine levels.

Authors:  F H Messerli; K Sundgaard-Riise; H O Ventura; F G Dunn; L B Glade; E D Frohlich
Journal:  Lancet       Date:  1983-10-29       Impact factor: 79.321

6.  Indirect measurement of blood pressure during exercise testing can be misleading.

Authors:  B A Gould; R S Hornung; D G Altman; P M Cashman; E B Raftery
Journal:  Br Heart J       Date:  1985-06

7.  Auscultatory measurement of arterial pressure during anaesthesia: a reassessment of Korotkoff sounds.

Authors:  E Pereira; C Prys-Roberts; J Dagnino; C Anger; G M Cooper; P Hutton
Journal:  Eur J Anaesthesiol       Date:  1985-03       Impact factor: 4.330

8.  "True" diastolic blood pressure.

Authors:  S R Levine
Journal:  N Engl J Med       Date:  1981-02-05       Impact factor: 91.245

9.  Cardiovascular responses during cuff inflation in subjects who have been sensitised to the measurement of their blood pressure.

Authors:  S Redman; J Dutch
Journal:  N Z Med J       Date:  1984-03-28

10.  The error in indirect blood pressure measurement with the incorrect size of cuff.

Authors:  L A Geddes; S J Whistler
Journal:  Am Heart J       Date:  1978-07       Impact factor: 4.749

View more
  3 in total

1.  What is the optimal interval between successive home blood pressure readings using an automated oscillometric device?

Authors:  Kazuo Eguchi; Sujith Kuruvilla; Gbenga Ogedegbe; William Gerin; Joseph E Schwartz; Thomas G Pickering
Journal:  J Hypertens       Date:  2009-06       Impact factor: 4.844

2.  Smartphone / smartwatch-based cuffless blood pressure measurement : a position paper from the Korean Society of Hypertension.

Authors:  Hae Young Lee; Dong-Ju Lee; Jongmo Seo; Sang-Hyun Ihm; Kwang-Il Kim; Eun Joo Cho; Hyeon Chang Kim; Jinho Shin; Sungha Park; Il-Suk Sohn; Wook-Jin Chung; Sung Kee Ryu; Ki Chul Sung; Juhan Kim; Dae-Hee Kim; Wook Bum Pyun
Journal:  Clin Hypertens       Date:  2021-01-25

3.  Simplified hypertension screening approaches with low misclassification and high efficiency in the United States, Nepal, and India.

Authors:  Olive Tang; Minghao Kou; Yifei Lu; Edgar R Miller; Tammy Brady; Cheryl Dennison-Himmelfarb; Arun More; Dinesh Neupane; Lawrence Appel; Kunihiro Matsushita
Journal:  J Clin Hypertens (Greenwich)       Date:  2021-09-03       Impact factor: 3.738

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.