Literature DB >> 33489341

Comparison of Advanced Threshold and SITA Fast Perimetric Strategies.

Bartosz L Sikorski1,2, Adriana Laudencka1,2.   

Abstract

PURPOSE: To compare the results obtained with two threshold strategies of visual field assessment: Humphrey SITA Fast (SFA) (Carl Zeiss Meditec) and PTS 2000 Advanced Threshold (ADV) (Optopol Technology) in healthy subjects and patients with glaucoma.
METHODS: The study sample comprised of 53 healthy volunteers and 69 patients with glaucoma. One eye of each patient was examined with the SFA and ADV strategies. The quantitative comparisons of test duration and global indices were made using correlation coefficients. The sensitivity and specificity of the algorithms were evaluated based on the GHT results and the adjusted Anderson-Patella (A&P) criteria.
RESULTS: The ADV test duration was shorter both in healthy subjects (by 5%) and patients with glaucoma (by 18%). The mean differences in MS values between the SFA and the ADV strategies were 1.06 ± 1.13 dB (MSSFA-MSADV) in healthy subjects and 1.00 ± 1.92 dB (MSSFA-MSADV) in patients with glaucoma. The MD index of ADV tests was lower than the SFA in the healthy (-0.74 ± 1.09 dB) (MSSFA-MSADV) and glaucoma group (-0.85 ± 2.19 dB) (MSSFA-MSADV). The mean differences in PSD values determined using both methods were -0.86 ± 0.67 dB (PSDSFA-PSDADV) and -0.53 ± 1.48 dB (PSDSFA-PSDADV) in healthy subjects and patients with glaucoma, respectively. Analysis of receiver operating characteristic curves built from MD and PSD indices show bigger area under curve in SFA than in ADV (0.983 vs.0.968 and 0.986 vs. 0.938, respectively). The GHT-based sensitivity and specificity for the ADV strategy were 92.75% and 77.36%, respectively, as compared to 92.75% and 90.57%, respectively, for the SFA strategy.
CONCLUSIONS: Both SFA and ADV enable effective identification of glaucomatous defects within 5 minutes. The ADV strategy, however, is significantly faster. The correlation between the global indices of SFA and ADV is very high. Both strategies offer very high sensitivity when using both GHT and A&P criteria.
Copyright © 2020 Bartosz L. Sikorski and Adriana Laudencka.

Entities:  

Year:  2020        PMID: 33489341      PMCID: PMC7803127          DOI: 10.1155/2020/7139649

Source DB:  PubMed          Journal:  J Ophthalmol        ISSN: 2090-004X            Impact factor:   1.909


  28 in total

1.  Comparison between Tendency-Oriented Perimetry (TOP) and octopus threshold perimetry.

Authors:  J Morales; M L Weitzman; M González de la Rosa
Journal:  Ophthalmology       Date:  2000-01       Impact factor: 12.079

2.  Between-algorithm, between-individual differences in normal perimetric sensitivity: full threshold, FASTPAC, and SITA. Swedish Interactive Threshold algorithm.

Authors:  J M Wild; I E Pacey; S A Hancock; I A Cunliffe
Journal:  Invest Ophthalmol Vis Sci       Date:  1999-05       Impact factor: 4.799

3.  Sensitivity and specificity of frequency-doubling technology, tendency-oriented perimetry, and Humphrey Swedish interactive threshold algorithm-fast perimetry in a glaucoma practice.

Authors:  Azfar C Wadood; Augusto Azuara-Blanco; Peter Aspinall; Abdel Taguri; Anthony J W King
Journal:  Am J Ophthalmol       Date:  2002-03       Impact factor: 5.258

4.  An automatic static perimeter, design and pilot study.

Authors:  A Heijl; C E Krakau
Journal:  Acta Ophthalmol (Copenh)       Date:  1975-06

5.  Optimization of the presentation pattern in automated static perimetry.

Authors:  J Spahr
Journal:  Vision Res       Date:  1975-11       Impact factor: 1.886

6.  Static perimetry: strategies.

Authors:  H Bebie; F Fankhauser; J Spahr
Journal:  Acta Ophthalmol (Copenh)       Date:  1976-07

7.  Evaluation of a new threshold visual field strategy, SITA, in normal subjects. Swedish Interactive Thresholding Algorithm.

Authors:  B Bengtsson; A Heijl; J Olsson
Journal:  Acta Ophthalmol Scand       Date:  1998-04

8.  An improved method to estimate frequency of false positive answers in computerized perimetry.

Authors:  J Olsson; B Bengtsson; A Heijl; H Rootzén
Journal:  Acta Ophthalmol Scand       Date:  1997-04

9.  Changes in differential threshold in patients with glaucoma during prolonged perimetry.

Authors:  A Heijl; S M Drance
Journal:  Br J Ophthalmol       Date:  1983-08       Impact factor: 4.638

10.  A visual field index for calculation of glaucoma rate of progression.

Authors:  Boel Bengtsson; Anders Heijl
Journal:  Am J Ophthalmol       Date:  2008-02       Impact factor: 5.258

View more
  1 in total

1.  Comparison of ZETA Fast (PTS) (Optopol Technology) and Humphrey SITA Fast (SFA) (Carl Zeiss Meditec) Perimetric Strategies.

Authors:  Basil Mathews; Jeff Laux; Cassandra Barnhart; David Fleischman
Journal:  J Ophthalmol       Date:  2022-02-03       Impact factor: 1.909

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.