Literature DB >> 11860968

Sensitivity and specificity of frequency-doubling technology, tendency-oriented perimetry, and Humphrey Swedish interactive threshold algorithm-fast perimetry in a glaucoma practice.

Azfar C Wadood1, Augusto Azuara-Blanco, Peter Aspinall, Abdel Taguri, Anthony J W King.   

Abstract

PURPOSE: To evaluate the sensitivity and specificity of the screening mode of the Humphrey-Welch Allyn frequency-doubling technology (FDT), Octopus tendency-oriented perimetry (TOP), and the Humphrey Swedish Interactive Threshold Algorithm (SITA)-fast (HSF) in patients with glaucoma.
DESIGN: A comparative consecutive case series.
METHODS: This was a prospective study which took place in the glaucoma unit of an academic department of ophthalmology. One eye of 70 consecutive glaucoma patients and 28 age-matched normal subjects was studied. Eyes were examined with the program C-20 of FDT, G1-TOP, and 24-2 HSF in one visit and in random order. The gold standard for glaucoma was presence of a typical glaucomatous optic disk appearance on stereoscopic examination, which was judged by a glaucoma expert. The sensitivity and specificity, positive and negative predictive value, and receiver operating characteristic (ROC) curves of two algorithms for the FDT screening test, two algorithms for TOP, and three algorithms for HSF, as defined before the start of this study, were evaluated. The time required for each test was also analyzed.
RESULTS: Values for area under the ROC curve ranged from 82.5%-93.9%. The largest area (93.9%) under the ROC curve was obtained with the FDT criteria, defining abnormality as presence of at least one abnormal location. Mean test time was 1.08 +/- 0.28 minutes, 2.31 +/- 0.28 minutes, and 4.14 +/- 0.57 minutes for the FDT, TOP, and HSF, respectively. The difference in testing time was statistically significant (P <.0001).
CONCLUSIONS: The C-20 FDT, G1-TOP, and 24-2 HSF appear to be useful tools to diagnose glaucoma. The test C-20 FDT and G1-TOP take approximately 1/4 and 1/2 of the time taken by 24 to 2 HSF.

Entities:  

Mesh:

Year:  2002        PMID: 11860968     DOI: 10.1016/s0002-9394(01)01424-6

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  14 in total

Review 1.  Imaging in glaucoma.

Authors:  Daniel M Stein; Gadi Wollstein; Joel S Schuman
Journal:  Ophthalmol Clin North Am       Date:  2004-03

2.  The distribution of visual field defects per quadrant in standard automated perimetry as compared to frequency doubling technology perimetry.

Authors:  Wadih M Zein; Ziad F Bashshur; Rola F Jaafar; Baha' N Noureddin
Journal:  Int Ophthalmol       Date:  2010-10-06       Impact factor: 2.031

3.  Remote image based retinopathy of prematurity diagnosis: a receiver operating characteristic analysis of accuracy.

Authors:  M F Chiang; J Starren; Y E Du; J D Keenan; W M Schiff; G R Barile; J Li; R A Johnson; D J Hess; J T Flynn
Journal:  Br J Ophthalmol       Date:  2006-04-13       Impact factor: 4.638

Review 4.  Effect of cataract extraction on frequency doubling technology perimetry in patients with glaucoma.

Authors:  M A R Siddiqui; A Azuara-Blanco; S Neville
Journal:  Br J Ophthalmol       Date:  2005-12       Impact factor: 4.638

5.  Population and high-risk group screening for glaucoma: the Los Angeles Latino Eye Study.

Authors:  Brian A Francis; Rohit Varma; Cheryl Vigen; Mei-Ying Lai; Jonathan Winarko; Betsy Nguyen; Stanley Azen
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-08-05       Impact factor: 4.799

6.  Comparative Analysis of Visual Field Plotting by Octopus Interzeag 1-2-3, Humphrey Field Analyser II and Frequency Doubling Perimetry in Glaucoma Patients in South Indian Population.

Authors:  A R Rajalakshmi; Elangovan Suma; D Ranjit Prabhu
Journal:  J Clin Diagn Res       Date:  2015-07-01

7.  Diagnostic ability of Humphrey perimetry, Octopus perimetry, and optical coherence tomography for glaucomatous optic neuropathy.

Authors:  B Monsalve; A Ferreras; P Calvo; J A Urcola; M Figus; J Monsalve; P Frezzotti
Journal:  Eye (Lond)       Date:  2016-11-11       Impact factor: 3.775

8.  Predicting progression of glaucoma from rates of frequency doubling technology perimetry change.

Authors:  Daniel Meira-Freitas; Andrew J Tatham; Renato Lisboa; Tung-Mei Kuang; Linda M Zangwill; Robert N Weinreb; Christopher A Girkin; Jeffrey M Liebmann; Felipe A Medeiros
Journal:  Ophthalmology       Date:  2013-11-26       Impact factor: 12.079

9.  Prediction of future scotoma on conventional automated static perimetry using frequency doubling technology perimetry.

Authors:  S Kogure; Y Toda; S Tsukahara
Journal:  Br J Ophthalmol       Date:  2006-03       Impact factor: 4.638

Review 10.  An examination of the hypothesis that intraocular pressure elevation episodes can have prognostic significance in glaucoma suspects.

Authors:  Charles McMonnies
Journal:  J Optom       Date:  2014-09-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.