Literature DB >> 3346261

The uncemented porous-coated anatomic total hip prosthesis. Two-year results of a prospective consecutive series.

J J Callaghan1, S H Dysart, C G Savory.   

Abstract

Fifty uncemented porous-coated total hip prostheses were implanted in forty-seven patients whose mean age was fifty-eight years. Clinical hip-rating scores, as described by Harris, were determined and anteroposterior and frog-leg lateral radiographs were made preoperatively, shortly postoperatively, and at three months, six months, one year, and two years postoperatively. The mean hip-rating score was 92 points (range, (range, 74 to 100 points) at one year and 92 points (range, 69 to 100 points) at two years. The thigh was slightly painful in nine patients (18 per cent) at one year and in eight (16 per cent) at two years. Fourteen hips (28 per cent) (in thirteen patients) caused a moderate or severe limp two years postoperatively; however, this complication appears to have been related more to the direct lateral approach that was used than to the prosthesis. Six (13 per cent) of the patients walked with a cane at one year and five (11 per cent) still required a cane at two years. Serial radiographic evaluations revealed that, between the first and second postoperative years, a progressive radiodense femoral line developed in twenty hips (41 per cent); a progressive acetabular line, in four hips (8 per cent); and progressive femoral sclerosis, in twelve hips (24 per cent). There was progressive loosening of beads from twelve (24 per cent) of the femoral components and from nine (18 per cent) of the acetabular components. The position of one acetabular and one femoral component changed. Two femoral shafts fractured, one intraoperatively and one fourteen months postoperatively. We concluded that the clinical results were encouraging in these patients at the end of two years. We are concerned, however, about the progressive radiodense lines, sclerosis, and loosening of beads as well as the slight, but persistent, pain in the thigh in eight patients.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3346261

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  45 in total

1.  [Early functional results with the Mayo-hip, a short stem system with metaphyseal-intertrochanteric fixation].

Authors:  R Hube; M Zaage; W Hein; H Reichel
Journal:  Orthopade       Date:  2004-11       Impact factor: 1.087

2.  Uncemented Porous Tantalum Acetabular Components: Early Follow-Up and Failures in 599 Revision Total Hip Arthroplasties.

Authors:  William J Long; Nicolas O Noiseux; Tad M Mabry; Arlen D Hanssen; David G Lewallen
Journal:  Iowa Orthop J       Date:  2015

3.  Three- to five-year results with the cementless Harris-Galante acetabular component used in hybrid total hip arthroplasty.

Authors:  H Kienapfel; W Pitzer; P Griss
Journal:  Arch Orthop Trauma Surg       Date:  1992       Impact factor: 3.067

4.  Promising mid-term results of total hip arthroplasties using an uncemented lateral-flare hip prosthesis: a clinical and radiographic study.

Authors:  Alex Leali; Joseph Fetto
Journal:  Int Orthop       Date:  2007-02-14       Impact factor: 3.075

5.  Does CT-based navigation improve the long-term survival in ceramic-on-ceramic THA?

Authors:  Nobuhiko Sugano; Masaki Takao; Takashi Sakai; Takashi Nishii; Hidenobu Miki
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

6.  Durability of second-generation extensively porous-coated stems in patients age 50 and younger.

Authors:  Jennifer A Moyer; Catherine M Metz; John J Callaghan; David W Hennessy; Steve S Liu
Journal:  Clin Orthop Relat Res       Date:  2009-09-01       Impact factor: 4.176

7.  Cementless total hip arthroplasty with AML, PCA and HGP prostheses.

Authors:  S K Hwang; J S Park
Journal:  Int Orthop       Date:  1995       Impact factor: 3.075

8.  Follow-up (6-9 years) results of the uncemented CLS Spotorno stem.

Authors:  J U Bulow; G Scheller; P Arnold; M Synatschke; L Jani
Journal:  Arch Orthop Trauma Surg       Date:  1996       Impact factor: 3.067

9.  The effect of hydroxyapatite coating on the fixation of hip prostheses. A comparison of clinical and radiographic results of hip replacement in a matched-pair study.

Authors:  J Huracek; P Spirig
Journal:  Arch Orthop Trauma Surg       Date:  1994       Impact factor: 3.067

10.  A prospective study of hip revision surgery using the Exeter long-stem prosthesis: function, subsidence, and complications for 57 patients.

Authors:  K Randhawa; F S Hossain; B Smith; Cyril Mauffrey; T Lawrence
Journal:  J Orthop Traumatol       Date:  2009-10-24
View more