Cocaine (COC) is one of the most widely consumed illegal drugs around the world. Street COC is commonly adulterated with pharmaceutical compounds that mimic or intensify the COC's sensory effect. Adulteration is performed to increase the profit of criminal organizations and each one has their own way of doing it. Therefore, determining the composition of seized COC samples (chemical profile) provides evidence for the police to track criminal organization networks and their activity patterns. Using filter paper as a substrate, we developed a multiple detection paper-based analytical device (PAD) that combines colorimetric and electrochemical measurements to discriminate COC samples according to adulterant's content. A regular graphite lead modified with a gold film made from Au leaf (graphite/Au) to improve electron transfer was used as a working electrode. Silver and Ag/AgCl were used as auxiliary and reference electrodes, respectively. The colorimetric device was patterned using a laser cutter and coupled to the electrochemical device using a double-sided tape, allowing simultaneous analysis to gather more analytical information about COC samples. Graphite/Au was characterized by scanning and transmission electron microscopies and electrochemical assays. The simultaneous colorimetric and electrochemical analyses combined to principal component analysis improved the analytical characterization of COC trial samples and provided a fast discrimination based on the assembled database.
Cocaine (COC) is one of the most widely consumed illegal drugs around the world. Street COC is commonly adulterated with pharmaceutical compounds that mimic or intensify the COC's sensory effect. Adulteration is performed to increase the profit of criminal organizations and each one has their own way of doing it. Therefore, determining the composition of seized COC samples (chemical profile) provides evidence for the police to track criminal organization networks and their activity patterns. Using filter paper as a substrate, we developed a multiple detection paper-based analytical device (PAD) that combines colorimetric and electrochemical measurements to discriminate COC samples according to adulterant's content. A regular graphite lead modified with a gold film made from Au leaf (graphite/Au) to improve electron transfer was used as a working electrode. Silver and Ag/AgCl were used as auxiliary and reference electrodes, respectively. The colorimetric device was patterned using a laser cutter and coupled to the electrochemical device using a double-sided tape, allowing simultaneous analysis to gather more analytical information about COC samples. Graphite/Au was characterized by scanning and transmission electron microscopies and electrochemical assays. The simultaneous colorimetric and electrochemical analyses combined to principal component analysis improved the analytical characterization of COC trial samples and provided a fast discrimination based on the assembled database.
Cocaine (COC) is a tropane alkaline-based compound that has stimulating
properties and is used by 18 million people aged 15–64 around
the world in 2017.[1] Its production is concentrated
in the Andean countries and has been growing in recent years (from
650 tons in 2013 to 1300 tons in 2017).[1] The leading illegal destinations of production are developed countries.
Individual analysis of seized drugs in 2017 indicates that 93% of
the COC in the United States was of the Colombian origin, 4% from
Peru, and 3% from an unknown source.[1]The physical (packaging and appearance) and chemical (major and
minor alkaloids, purity, chemical class, and cutting agent—diluent
or adulterant) analyses of the seized COC sample provide its chemical–forensic
profile.[2,3] Cataloged in large databases together with
detailed data—criminal cases, sample mass, and date and place
of seizure—such profiles provide strategic evidence to track
the criminal organization networks and their activity patterns, as
well as the structure and evolution in time and space in the illicit
drug market.[3,4]Criminal organizations often blend diluents such as sugar, starch,
and carbonates[2] or pharmaceutical compounds
as adulterants of COC. Some of these adulterants are phenacetin and
aminopyrine (AMI), which have an analgesic and antipyretic effect.
At the same time, they are carcinogenic and toxic to some extent,
being banned in some countries.[5,6] Besides that, other
chemicals such as levamisole, paracetamol, caffeine, procaine, benzocaine,
boric acid, and lidocaine[7−9] can be added, and each criminal
organization has its own approach to adulterating or adding compounds
to the drug.[3] These substances dilute the
drug rising the organization profits. Furthermore, adulterants can
mimic or intensify the pharmacological effect of COC.[10]In a crime scene, the found substances can be examined by presumptive
color tests to start an inquiry in the field.[6,11] One
of those tests is based on the well-known Scott reaction, where the
product between cobalt thiocyanide and COC generates blue color.[12] However, this reaction is susceptible to produce
false-positive results because of interferences of pharmaceutical
compounds.[13,14] In this sense, Tsumura et al.
have modified the Scott test aiming for interference minimization
in COC detection.[14] Using the electrochemical
method, electrochemiluminescent-based sensors have been developed
for selective detection of tropane alkaline-based compounds.[15] In addition, the paper-based analytical devices
(PAD) have drawn attention for being quickly built to improve chemical
analyses[8] and the potential to be used
in-field[16,17] with portable detectors such as a smartphone[6,18] and a potentiostat.[19] Thus, allowing
more accurate screening analysis even in the absence of well-trained
professionals[6] mediated by chemometric
pattern recognition.[20]The outstanding characteristics of PADs, such as low cost, simplicity,
easy-to-use, and fast analysis time, attracted the researchers’
attention.[17] The paper fibers have microfluidic
properties that can be explored to separate a mixture of compounds
and are an excellent platform for storing chemical (bio)reagents.[17,21] Their surface can be easily modified to generate controlled flows
of fluids,[17] or to confine liquid solutions
to carry out spot tests.[6] In 2007, Whitesides’
group brought up the use of paper for colorimetric analysis of glucose
and protein without the need for external equipment[22] and in 2009, the group proposed a cheaper approach using
wax printing.[23] In 2009, Henry’s
group coupled the electrochemical detection to portable paper devices,
providing higher selectivity and, mainly, improved sensitivity as
compared to the colorimetric detection method.[24]In fact, both types of detection, colorimetric and electrochemical,
can complement each other allowing the analysis of heavy metals for
environmental application with high sensitivity for chemical species
that could not be detected by a simple color change.[25] Recently, our group demonstrated the use of electrochemistry
for sample processing followed by colorimetric determination of low
concentrations of COC adulterants on a microfluidic PAD (μPAD).[8]In this work, we present a paper-based device as an analytical
platform combining colorimetric and electrochemical detections (Color-ePAD).
The device was fabricated using a filter paper and hydrophobic wax
barriers to delimit the wells to accommodate the electrodes. A second
layer for colorimetric detection, in which the PAD was patterned using
a laser cutter, was attached to the electrochemical device using a
double-sided tape. A common three-electrode cell configuration was
used. A regular graphite lead modified with a gold film (graphite/Au)
prepared from Au leaf (usually employed in decorative crafts and wedding
candies) was used as a working electrode.[26] Silver and silver/silver-chloride were used as auxiliary and reference
electrodes, respectively. The developed device was used for proof-of-concept
analysis of the COC samples and for a fast-qualitative discrimination
of the samples according to their composition, which was carried out
through principal component analysis (PCA). To the best of our knowledge,
this is the first time that both detection strategies are performed
simultaneously to obtain distinct and complementary information about
the sample.
Materials and Methods
Reagents
All solutions were prepared
using analytical grade reagents and deionized water with a resistivity
of 18.2 MΩ cm (25 °C) (Direct-Q 5UV, Merck Millipore, Massachusetts,
USA). The reagent 4-dimethyl-aminoantipyrine (AMI) was purchased from
Alfa Aesar (Massachusetts, USA). Orthophosphoric acid (85%) and cobalt(II)
thiocyanate (96%) were acquired from Merck (Darmstadt, Germany). Anhydrous
monosodium phosphate was purchased from Synth (Diadema, Brazil). Sulfuric
and hydrochloric acids were purchased from J. T. Baker (Phillipsburg,
USA).The gold leaf 23 kt (79 × 79 mm) was purchased from
Nazionale Battitura Metalli srl (Milan, Italy). A qualitative filter
paper (grammage 80 g m–2; thickness: 0.16 mm; particle
retention: 4–12 μm; filtration speed: 20–25 s;
from Unifil, Rio Grande do Sul, Brazil) of size 60 × 60 cm was
cut into A4 size (210 × 297 mm) to fit into the wax printer.
Whatman Grade 1 qualitative cellulose filter paper was purchased from
GE Healthcare (Chicago, USA). The 0.9 mm thick graphite leads, 2B
(from CIS, São Paulo, Brazil), were purchased from a local
market. Ag ink was acquired from Joint Metal LTDA (Diadema, Brazil).
The seized COC samples were granted by the Criminalistics Institute
of the State of São Paulo (Brazil) via a license with the Institute
of Chemistry. The seized COC purity (92%) and composition was determined
by gas chromatography with flame ionization detection. The samples
for use with the Color-ePAD were ground in a mortar and pestle and
then dissolved in the phosphate buffer solution (PBS) before analysis.
Preparation of Au Film for Graphite Modification
The precursor reagent, AuCl4–, was
obtained by dissolving 12 mg of Au leaf with a purity grade of 88%
wt/wt in 100 μL of orange color reverse aqua regia (HNO3/HCl; 3:1 vol/vol). The resulting yellow solution was diluted
to 44 mL with 0.5 mol L–1 H2SO4 aqueous solution, obtaining a 1.2 mmol L–1 AuCl4– solution.Prior to the electrodeposition
of the Au film, the graphite lead was prepared following the steps
shown in Figure S1. First, the graphite
surface was polished with a piece of paper (not shown in the Figure S1). Then, (step 1) ∼2 mm of one
end of the graphite lead was protected with a 2 × 10 mm piece
of a blue adhesive tape (3M) cut with a CO2 laser engraver
(Work Special Laser). The laser wavelength was 10.6 μm and the
pulse duration was ∼14 μs. The remaining exposed area
on the tip of the graphite was protected with an extra piece of the
same adhesive tape (step 2). After that, (step 3) the nonprotected
area of the graphite was covered by painting with a waterproof spray
(Spray Water Proof, Global) and left to dry, 15 cm apart from an infrared
lamp (PAR38E 150 W, Philips) for a few minutes. Finally, (step 4)
the tape was removed defining the area for electrodeposition of the
Au film.The electrodeposition of the Au film was carried out by chronoamperometry
(cAMP) in the AuCl4– acidic solution,
under vigorous stirring with a magnetic bar, at room temperature.
The Au film deposition was evaluated at −1, −2, −3,
and −4 V versus a conventional Ag/AgCl (KCl 3 mol L–1) reference electrode during 120 s. The most uniform film was obtained
when −4 V was applied for 120 s using a Pt auxiliary electrode.
Potentials beyond −4 V could be evaluated
because potentiostat-current range was limited up to 1 A. Throughout
the electrodeposition, utmost care was taken to position the three
electrodes as close as together. A potentiostat PGSTAT 128N (Metrohm,
Barendrecht, Nederland) was used for all electrochemical experiments.
Fabrication of the Color-ePAD
The
ePAD device was prepared using a filter paper patterned with a wax
barrier using a wax printer (Xerox ColorQube 8570) (Figure A). The printed paper was then
exposed to a hot plate (Hobby Line MetaInox) at 80 °C long enough
to allow the melted wax penetrate the three-dimensional structure
of the paper, forming hydrophobic barriers. The template was drawn
using Power Point software (Microsoft). It consisted of a 9 ×
33 mm rectangular frame around three aligned circular-hydrophilic
zones 6 mm apart from each other; two of them with 5 mm diameter and
another one with 6 mm (right end of Figure A). They were interconnected by 1.5 mm wide
microfluidic channels. Silver tracks were painted with silver ink
onto the hydrophilic zones at both ends of the PAD to create the auxiliary
and the reference electrodes. The Ag track in the 6 mm-diameter zone
was oxidized to AgCl in a 0.1 mol L–1 HCl solution
by cyclic voltammetry (CV). The CV procedure was performed at scan
rate of 100 mV s–1 for five cycles, varying from
−0.1 to 0.15 V (vs conventional Ag/AgCl (KCl 3 mol L–1) reference electrode) with end potential at 0.14 V. Figure S2 shows an Ag/AgCl electrode aged for
a month indoors. While the color of AgCl was preserved, suggesting
low susceptibility to the action of ambient air, Ag darkened indicating
a sulfidation of the surface mainly because of the action of traces
of H2S.[27] The graphite/Au working
electrode was assembled parallel to the auxiliary electrode in the
sampling zone.
Figure 1
(A) Fabrication of ePAD using a wax-patterned filter paper and
graphite/Au, AgCl, and Ag as working, reference, and auxiliary electrodes,
respectively. (B) Fabrication of the ColorPAD by laser cutting a filter
paper. The inset is a real picture of a Color-ePAD device. Highlighted
are the working, reference, and auxiliary electrodes of the ePAD,
the sample inlet channel, and the dry cobalt(II) thiocyanate in the
ColorPAD detection area. The dimensions are shown in the figure.
(A) Fabrication of ePAD using a wax-patterned filter paper and
graphite/Au, AgCl, and Ag as working, reference, and auxiliary electrodes,
respectively. (B) Fabrication of the ColorPAD by laser cutting a filter
paper. The inset is a real picture of a Color-ePAD device. Highlighted
are the working, reference, and auxiliary electrodes of the ePAD,
the sample inlet channel, and the dry cobalt(II) thiocyanate in the
ColorPAD detection area. The dimensions are shown in the figure.Shortly after the submersion of the electrodes in liquid by addition
of a drop of 3 mol L–1 KCl solution to the reference
electrode area and a drop of sample to the sampling area, these solutions
traveled by capillary action until the hydrophilic area in the center
where the electrolytic contact between the semicells is established.
This salt bridge action resembling the porous junction of a conventional
reference electrode can be visually illustrated by using colored solutions
(Figure S3).[28] In this work, the conventional Ag/AgCl (KCl 3 mol L–1) reference electrode was denominated Ag/AgCl whereas the reference
electrode Ag/AgCl (KCl 3 mol L–1) on the paper as
Ag/AgCl”.The ColorPAD was also fabricated on the same type of filter paper
(Figure B). The microfluidic
channel (3 × 10 mm), the 10 mm-diameter detection zone, and the
support for connecting to the ePAD were cut with a CO2 laser
engraver with the template drawn in the RDworks software. After that,
3 μL of 4% wt/wt cobalt(II) thiocyanate solution prepared in
PBS, pH 2, was deposited in the detection area and allowed to dry
at room temperature. The ColorPAD was attached to the ePAD using double-sided
tape thus integrating the electrochemical and colorimetric detection
in a single device.
Microscopic Characterization
Transmission
electron microscopy (TEM) images were obtained using a JEM-2100 equipment
(JEOL) at an acceleration voltage of 200 kV. The samples were prepared
by ultrasonic removal of the Au film in water/ethanol (1:1 vol/vol).
Then, 5 μL of the suspension was deposited onto an ultrathin
carbon film-coated copper grid (Ted Pella Inc.). The scanning electron
microscopy (SEM) images were obtained with a working distance of 3
mm, an electron beam acceleration of 2–5 kV, and a magnification
of 5000–30,000 times with the JSM 7401F equipment (JEOL). The
optical microscopy images were obtained with an USB digital microscope
(Novadigital).
Electrochemical Measurements
The
CVs were registered with Autolab PGSTAT 128N (Metrohm) using graphite/Au
or nonmodified graphite, Ag/AgCl, and Pt as working, reference, and
auxiliary electrodes, respectively. CVs were recorded in a beaker
with a scan rate of 50 mV s–1 in 0.5 mol L–1 H2SO4 solution to analyze the degree of coverage
and the gold crystallographic planes.[29−31] The redox signals of
nonmodified graphite in aqueous H2SO4 media
decreased as a function of the deposition of the Au film indicating
suitable coverage. The Au-anodic broad wave showed the polycrystalline
nature of the Au deposit. In H2SO4, yet the
amount of deposited Au was monitored by the amount of charge involved
in the reduction of the Au oxides formed in the anodic scan. The reproducibility
was evaluated in this acidic medium by monitoring the anodic and cathodic
waves of Au of 10 different graphite/Au electrodes. CVs were also
recorded in the PBS solution at pH 2 to evaluate the graphite coverage
degree by the Au film. In the same buffer solution, the electrochemical
behaviors of AMI, ascorbic acid (AA), and COC were evaluated. CVs
were also registered with a scan rate of 2 mV s–1 to evaluate the effectivity of the electronic transfer from graphite/Au
and nonmodified graphite electrodes. In this experiment, a conventional
Au electrode (disk with ⌀ = 1.5 mm) was used for comparison
purpose. Differential pulse voltammograms (DPVs) of 10 mmol L–1 AMI were recorded in PBS (pH 2) using ePAD to evaluate
the relative standard deviation (RSD) of the current intensity and
the peak potential. DPV experiments were performed with 10 mV steps
of 25 mV of amplitude, 50 ms of modulation time, and 400 ms of interval
time.The Nyquist plots of graphite/Au and nonmodified graphite
were recorded with the ePAD after adding 50 μL of 0.1 mol L–1 KNO3 solution containing 2 mmol L–1 of [Fe(CN)6]3–/4– to the sampling area and 50 μL of 3 mol L–1 KCl solution to the reference electrode area. The electrochemical
impedance spectroscopy assays were performed at a half-wave potential
of ∼0.15 V for both electrodes (graphite/Au and graphite),
determined by open circuit potential (OCP) using Ag/AgCl″ and
Ag as a reference and an auxiliary electrode, respectively. Alternating
potential with an amplitude of 10 mV in the frequency range of 0.10
to 105 Hz was used. All experiments were performed at room
temperature. The semicircles were analyzed using the electrochemical
circle fit method available in the Nova 2.1 software (Metrohm Autolab),
which considers the Randles’ equivalent electrical circuit
without taking into account the diffusion-controlled mass transport
process (Warburg constant).
Colorimetric Analyses
Colorimetric
assays of the PBS (pH = 2) with and without COC (7.5 mmol L–1) or AMI (10 mmol L–1) were performed by adding
50 μL of the solution to the ePAD sampling and then dipping
the inlet channel of the ColorPAD into the drop until the solution
reaches the upper edge of the ColorPAD detection zone through capillary
action (circa 30 s). After that, the ColorPAD was manually detached
from paper holders that connected it to the ePAD. Images were registered
after 2, 5, 10, and 20 min of reaction using Redmi Note 7 smartphone
(Xiaomi, Beijing, China) based on a 6.5 cm-height support with internal
lighting to maintain lighting and focal length constant; a support
similar to that was used in a previous work.[18]These images of the detection zone of the paper have been
standardized to an average intensity of 60% of the red, green, and
blue (RGB) channels using the Gimp software (Figure S4). By using the same software, the RBG values were evaluated
in the half-moon shaped regions of the images where the cobalt(II)
thiocyanate complex reacted with COC (zone 1) and AMI (zone 2) (Figure S4).
Analysis of COC Samples with Color-ePAD Device
Solutions containing 230 mg COC/AMI mixtures in different ratios
were prepared in 100 μL of PBS (pH = 2), adequate to solubilize
COC (pKa 8.6).[9] The concentrations and ratios of COC/AMI mixtures were: 230 mg of
COC (7.5 mmol L–1, 100:0); 184 mg COC and 46 mg
AMI (6 mmol L–1 COC/2 mmol L–1 AMI, 80:20); 115 mg COC and 115 mg AMI (4 mmol L–1 COC/5 mmol L–1 AMI, 50:50); 46 mg of COC and 184
mg of AMI (1.5 mmol L–1 COC/8 mmol L–1, 20:80); and 230 mg of AMI (10 mmol L–1, 0:100).Each solution was loaded in the sampling zone of a new ePAD, into
which the inlet channel of the ColorPAD was immersed for circa 30
s. After the end of the run, the device was detached, the CV was started
at 50 mV s–1, and three cycles were recorded. Concomitantly,
photos of the ColorPAD were obtained after 2, 5, 10, and 20 min of
the reaction, as described above.
Principal Component Analysis
The
RGB and CV-current raw data were analyzed by PCA. The principal components
(PCs) are orthogonal eigenvectors in a reduced space, and they were
calculated using Statistica 13.5 software. The currents and RGBs were
used as the input data to compose the PCA matrices. Each CV generated
1024 variables, while colorimetry generated 24, three variables (RGB)
in two different regions of analysis collected at a distinct time
(2, 5, 10, and 20 min). The matrix columns were self-scaled according
to eq to give the same
weight to all variables.[32] Where x is the value of variable
located at line i and column j, is the average of the column j, and s is the standard
deviation of column j.
Analysis of Au Sheets by Energy-Dispersive
X-ray Fluorescence
The graphite surface modified with the
Au film was prepared using the Au leaf as the precursor. The Au leaf
(1 cm2) was analyzed by energy-dispersive X-ray fluorescence
spectrometry (EDXRF) with the EDX720 instrument from (Shimadzu, Columbia,
USA) in atmospheric air. The analysis window was that of Na (11)—U
(92) with an Rh X-ray tube with 50 kV and a current of 240 μA,
an analysis time of 60 s, and a collimating lens of 10 mm.
Results and Discussion
Color-ePAD Fabrication
We prepared
a PAD on filter paper with colorimetric (ColorPAD) and electrochemical
(ePAD) detections (Color-ePAD) (Figure inset). Both techniques can be used simultaneously
to extract information from the COC samples, increasing the amount
of data and allowing the identification of that drug with the support
of a chemometric method, PCA.The paper platform of ePAD was
fabricated, creating a 5.0 mm diameter sampling zone, defined in such
a way that a small sample volume (50 μL) is enough for the electrochemical
and colorimetric assays. A drop of 3 mol L–1 KCl
needs also to be added to the reference electrode zone. The relatively
narrow (1.5 mm) and long (2 × 6.0 mm) microfluidic channels connect
those two electrode areas with a circular central merging area that
also prevents the contamination of the reference electrode by the
sample solution.[28] A shift of +0.1 V in
CV of AMI was observed when compared to other referenced to Ag/AgCl
(Figure S5) caused by ohmic drop between
the working electrode and the channel leading to the reference electrode.For the fabrication of the working electrode, a graphite lead of
low electric resistance (<5 Ω) was used. This electrode material
has been used to detect heavy metals and drugs using electrochemical
techniques.[33] It is composed of fine graphite
powder (∼65%) mixed in a clay matrix (∼30%) and binders
(wax, resin, and polymers).[33] The working
electrode was prepared following the procedure previously reported,[34] except that AuCl4– was obtained from the dissolution of the Au leaf with reverse aqua
regia[35] instead of using the commonly employed
HAuCl4 reagent.[34,36−38] In this work, taking advantage of the availability of the Au leaf
used in decorative crafts and cooking,[26] a fast, low-cost micro-scale preparation of AuCl4– was carried out by dissolving the gold with reverse
aqua regia. The general reaction of Au with reverse aqua regia is
shown in eq .[35] The Au concentration in the leaf was 88% (wt/wt),
which was determined by the elemental analysis technique EDXRF as
shown in Table S1.The manufacturing of the working electrode was optimized by applying
different potentials using the cAMP technique. These potentials ranged
from −1 to −4 V (vs Ag/AgCl). The Au film distribution
on the graphite surface was evaluated by monitoring the electrochemical
signal of the substrate and by optical microscopy. In the case of
an incomplete surface coverage, the characteristic signal of graphite
in the H2SO4 solution (between 0.2 and 0.7 V)
could interfere with the measurements of the target analytes (Figure S6A).More negative potentials applied during the reduction of AuCl4– decrease the graphite signal in the CV
registered in the H2SO4 solution (Figure S6B), until it disappears completely at
potentials below −3 V. It was also observed that the substrate
signal decreased in PBS as higher energy potentials were used for
AuCl4– reduction (Figure S6A). By means of optical microscopy, it was possible
to correlate the signal decrease observed and the graphite surface
coverage by Au (Figure S6C). Additionally,
the faradaic currents associated with the formation (1.2–1.5
V) and reduction (0.9 V)[30] of Au oxides
increased (Figure S6B). The progressively
more negative potentials generated an augment in the number of active
sites for AuCl4– electrodeposition[37] increasing the amount of Au deposited and electrode
electroactive area (Figure S6).Besides the Au coating, the electrochemical response to the probe
molecule AMI was monitored.[5,7] The potential window
of CVs using graphite/Au was limited to 1.15 V (vs Ag/AgCl) to avoid
interference of the Au-oxidation faradaic current in the analyses.At graphite/Au, AMI showed two well-defined anodic peaks at 0.65
and 0.95 V (vs Ag/AgCl). The peaks were 18 and three times higher
than those obtained with a nonmodified graphite (Figure S7), indicating a larger reactivity of AMI on the graphite/Au
surface than on nonmodified graphite. The higher current values observed
current may be related to the increase in the surface area because
of the Au-film deposition. Based on the oxidation mechanism of AMI
on the platinum electrode,[5] the first peak
at 0.65 V (vs Ag/AgCl) can be attributed to the one electron oxidation
of the tertiary enamine attached to the pyrazole ring with the subsequent
formation of a radical iminium cation, which may undergo demethylation
to form a secondary amine that can be oxidized to a hydroxylamine
group at 0.95 V (vs Ag/AgCl). Another mechanism path can be described
by the stabilization of the iminium cation, and the current peak at
0.95 V can be attributed to electrooxidation of the methylated carbon
of the pyrazole ring, according to the mechanism proposed at the glassy
carbon electrode.[39] The COC did not show
electroactivity under these conditions (Figure S7).The ColorPAD was prepared using the same type of filter paper.
However, instead of delimiting the hydrophilic channels and detection
zone with wax, the edges of the device were cut using a CO2 laser. The detection zone diameter was optimized by varying the
size in a range of 4–10 mm (Figure S8). The larger diameter favored the solution spreading, which then
evaporated faster, revealing the blue color of the Co/COC complex,
insoluble in the aqueous medium.[40] Therefore,
10 mm diameter was chosen for the proposed device. The width and length
of the microfluidic channel as well as the type of cellulose filter
paper influence the fluid transport regime (speed and flow rate) and
have been used to promote efficient separation or mixing.[41] In the present work, the channel is intended
just to deliver the sample to the detection zone of the ColorPAD,
so a channel of 3 × 10 mm was adopted.The pinkish aqueous cobalt thiocyanate solution applied on the
paper turned royal blue color after drying (Figure S9), because of the formation of the [Co(SCN)4]2– complex as water evaporates out. To evaluate whether
the paper’s quality would influence the result, a cobalt thiocyanate
solution was added to both Whatman no 1 paper and the filter paper
used to manufacture devices. A blue color was observed on both papers
(Figure S9), which is consistent with the
literature[40] that the paper could produce
a false positive in the color test of a seized sample supposedly from
COC. However, it immediately returned to the initial pinkish color
when wetted again with the PBS solution. These color changes did not
occur with the COC (Figure S9), or with
the AMI (data not shown), after adding PBS to the blue complex, as
expected for the formation of insoluble stable precipitates with these
compounds.When high concentrations (solid) of COC (Figure S9) and AMI (data not shown) were added to the wet paper with
the Co thiocyanate solution, such Co/COC and Co/AMI complexes showed
dark blue colors almost indistinguishable from the blue color of the
papers. However, a change from dark blue to Capri blue or medium blue
was observed when lower concentration solutions were added to the
ColorPAD. Another factor that may have contributed to the change in
color tone was the spread of the mixture promoted by the paper’s
capillarity. Therefore, the blue hues of Co thiocyanate, Co/AMI, and
Co/COC complexes can be differentiated on paper (Figure S9).The reaction with Co thiocyanate is not selective for COC as demonstrated,
and may generate blue color with controlled-use drug as lidocaine,
dibucaine, chlorpromazine[14] in addition
to AMI. Therefore, there are risks of producing false-positive results
or dubious results, for example, the appearance of purple color with
milk powder.[42] For this reason, Tsumura
and collaborators[14] suggested performing
the Scott test in three stages: (i) reaction of the suspected sample
with Co thiocyanate in an aqueous medium with glycerin for the appearance
of the blue precipitate; (ii) resolubilization with concentrated HCl
to monitor the color disappearance; and (iii) the extraction of the
complex with chloroform producing a blue solution. If these three
steps are contemplated, the accuracy of the results of the preliminary
exams for COC will be higher, reducing the incidence of false positives.Another factor that provides strong evidence for the COC presence
in the seized sample is the fast formation of the complex. Figure S10 shows that the sample containing COC
exhibited Capri blue precipitates in 2 min of reaction. It is important
to note that the precipitate was formed and impregnated the ColorPAD
fibers in a region close to where the thiocyanate reagent was deposited.
It assumed an arc shape as a result of the drag generated by the solution
flow (Figure S10). This color gradually
became more intense over time while the excess of thiocyanate solution
continued to be carried by the continuous flow.After 10 min of the reaction, the pinkish thiocyanate located on
the upper part of the ColorPAD became darker, being more intense in
the sample that contained only AMI (Figure S10). After 20 min, it showed medium blue color indicating the presence
of AMI. The dark blue that developed on the paper after running the
PBS solution without any analyte appeared in the upper region, close
to the border. This suggests that the formation kinetics of the Cothiocyanate and COC complex is faster than with AMI. These observations
made it possible to identify the analytes according to the region
of the device.
Microscopic and Electrochemical Characterization
of the Graphite/Au Electrode
To assess the morphology of
our working electrode, SEM images of the graphite with and without
Au film modification were acquired. Images of bare graphite revealed
thin and flat packaged structures (tactoids)[43] composed of graphite aggregate sheets, oriented in different directions,
as shown in Figure A,B. When the graphite was modified with the Au film, these structures
were preserved, and Au was deposited on them (Figure C,D). In the micrograph with higher magnification,
it is possible to observe the presence of submicrometric Au particles,
which provide defects (i.e., folds and edges) on the surface.
Figure 2
SEM images of the graphite tip before (A,B) and after (C,D) deposition
of Au.
SEM images of the graphite tip before (A,B) and after (C,D) deposition
of Au.TEM images revealed that the Au film is formed by aggregated Au
particles of different sizes (Figure S11). In addition, high-resolution TEM images (Figure S12) showed that the Au film exhibited a fringe distance of
0.23 nm, characteristic of the Au(111) crystallographic plane of the
face-centered-cubic lattice of gold [JCPDS 04-0784].[37] Complementary analysis by selected area electron diffraction
(SAED) suggested the presence of (200), (220), and (311) planes, as
shown in Figure S12.[36,38,44] The anodic peaks at 1.2 and 1.4 V (vs Ag/AgCl)
observed in the CV recorded in the H2SO4 solution
(Figure S6B) can be associated with low-index
(100) and (111) crystalline planes, respectively. Additionally, the
shoulder observed at 1.3 V can be attributed to the (110) plane,[29,30,34] showing the crystalline facets
exposed to the electrolyte solution.The electrochemical behavior of the graphite/Au electrode was compared
to that of a nonmodified graphite (Figure S13). Electrochemical impedance spectra (Nyquist plots) were acquired
at the half-wave potential of the equimolar system of the [Fe(CN)6]3–/4– redox pair, measured at OCP.
The applied potential was ∼0.15 V (vs Ag/AgCl″) for
both electrodes.The semicircle in the high-frequency region of the impedance spectrum
represents the electrochemical process limited by the charge transfer
resistance (RCT) in the electrode/solution
interface.[45] The nonmodified graphite showed
a semicircle with 644 Ω, whereas the deposition of the Au decreased
the resistance to 3 Ω, suggesting an increase in the electron
transfer rate at Au, favored also by the greater surface area highlighted
in Figure . The diffusion
region presented a nonlinear tail because of the capacitive behavior
of electrodes resulting from the irregular microstructures of graphite
and the presence of nanometric structures of Au.[46]AA was selected as a redox probe for CV measurements. An increased
height and definition of the broad-anodic wave attributed to the oxidation
of ascorbate to dehydroascorbate on the gold electrode involving two
electrons[36] was observed on Au-coated graphite,
in contrast to the bare graphite electrode. This effect was more noticeable
when a more negative potential was used for the electrodeposition
of Au, suggesting an improvement in the electron transfer rate (Figure S14). Also, a slight anticipation (∼50
mV) of the anodic peak onset was observed on a graphite/Au electrode
(prepared at −4 V (vs Ag/AgCl)) compared to that observed on
a nonmodified graphite.A shift of 300 mV (to lower overpotential) of the AA peak onset
was also observed in CV recorded on graphite/Au compared to that of
a conventional Au disk electrode (Figure S14). A similar behavior has been observed for an Au disk electrode
modified with electrodeposited Au.[36] This
effect could be attributed to adsorption of molecules on the electrode
surface affecting the transition state and, therefore, the activation-energy
barrier, thus facilitating the chemical reaction on the surface.[47] Atoms in kinks and edges interact more strongly
with the analyte[30,47] than the ones on bulk surfaces.
The geometry of the material influences the crystallographic planes
exposed to solution, and these in turn interact differently with the
analytes, increasing or decreasing the catalytic activity.[48] For example, copper oxide (Cu2O)
nanocubes that have (100) orientation favor the nonenzymatic and selective
oxidation of glucose.[48] The Au crystallographic
planes (311) have a greater catalytic effect than the monocrystalline
(111) or (100) surface on glucose detection.[49] The graphite/Au electrodes exhibited a mixture of different crystal
facets, they had mostly (100) and (111) planes in contact with the
solution, presenting a superior electrochemical performance than conventional
Au or nonmodified graphite electrodes.As mentioned, adsorption can decrease the energy barrier by activating
the molecules[47] and, consequently, can
promote the occurrence of the reaction at lower overpotentials. Such
an effect can explain better the definition of the anodic wave of
AA.[36] To evaluate if the marked increase
in the current signal is a result of this effect or due simply to
increased electroactive area or roughness, it is necessary to normalize
the measured currents for the effective area of the electrode.[50]The electrochemical surface area of nanostructures can be measured
by different ways.[7,50−52] One of the
recommended ways is by monitoring the nonfaradaic capacitive current
as a function of the scan rate, which should present a linear relationship.
The parameter obtained for the nanostructured and flat electrodes
can be used to obtain or compare the electroactive areas.[50]It is worth noting that when graphite was used as an electrode
(Figure S14), the mass transport approaches
a steady state regime, observed when the radius of the electrode is
smaller than the diffusion layer.[53,54] The graphite
surface with tactoids may have created microregions promoting such
a similarity. In contrast, when a conventional Au disk electrode was
used, transient mass transport was observed. This behavior is seen
when the diffusion layer is smaller than the electrode radius.[53]
Reproducibility of Graphite/Au Electrode Fabrication
As previously discussed, when applying −3 and −4
V (vs Ag/AgCl), a well-distributed Au film was formed on the graphite
surface. Because of the higher energy, a potential of −4 V
reduced Au more deeply into the tactoids of graphite sheets as shown
in Figure , thus being
more suitable to fully cover the surface area accessible to the electroactive
analytes. Consequently, a preparation method with a relatively high
reproducibility rate of 83% was developed. Indeed, 10 out of 12 manufactured
electrodes presented an adequate Au film coating and the peak currents
at 1.26, 1.43, and 0.95 V of CVs registered in H2SO4 solution had a RSD of 7.5, 6.8, and 9.5%, respectively (Figure S15). On the other hand, when applying
−3 V, the reproducibility decreased to 50% and only six out
of 12 electrodes showed a suitable Au coating.Additionally,
when using −4 V for the deposition of the Au film on the graphite
surface, the RSD of the peak height at 0.65 V for AMI was 8% (56 ±
4.5 μA) (Figure S16). It is noteworthy
that the peak potential of AMI at 0.72 V versus Ag/AgCl″ electrode
on paper presented a shift to an extent of 0.08 V (Figure S16). This represents an improvement in comparison
with a Ag pseudo-reference (0.12 V) that we believe is because of
the use of KCl solution to wet the true Ag/AgCl reference electrode
and to the narrow “salt bridge” channel with a relatively
large central contact area, protecting the reference electrode from
the sample solution. The pseudoreference has the silver surface exposed
to the electrolytic sample, so that its potential depends on the chloride
concentration (or other halide or pseudohalide), being also susceptible
to disturbances by adsorption of chemical compounds from the sample.
It is worth noting that this observed variation can be lowered even
more in a larger scale optimized device fabrication instead of the
manual silver painting and anodization of the reference electrode
for each PAD.
Proof-of-Concept Application of the Color-ePAD
to COC Samples
The electrochemical analyses of the COC samples
were accomplished by CV with three cycles that lasted 155 s and required
50 μL of the sample prepared in PBS (pH 2). As shown before
in Figure S16, each electrode presented
a slightly different behavior in the AMI solution. As expected, a
similar behavior was observed for the analysis of the COC sample containing
AMI as a cutting agent. Shifts in the AMI peak potential in a range
of 0.07 V and different current intensities (28 ± 2 μA)
were observed (Figure S17).To circumvent
these signal fluctuations, the sample analysis can be done using the
standard addition method to eliminate the matrix effect[55] but a different strategy is demonstrated in
this work. We recorded the voltammetric and colorimetric responses
(n = 5) of each COC/AMI solution prepared using the
COC sample granted by Criminalistic Institute of the State of São
Paulo (Brazil) to assemble the database for PCA, an unsupervised chemometric
technique that reduces a larger set of variables into a smaller number
of orthogonal eigenvectors, the PCs that carry as much variance as
possible.[18] Thus, by combining electrochemical
and colorimetric data obtained with the Color-ePAD, we developed an
analytical method that compare and group the samples according to
similarities, thus allowing the determination of their composition.
Therefore, the analytes can be quantified quickly and without the
need of trained personnel to perform the analysis.The CV was chosen for providing information about the samples during
both, the forward and reverse scans. The currents without subtracting
background were introduced in the data matrix, and each column was
self-scaled to minimize the influence of a dominant variable.[32] In Figure A, the PC1 of the 25 samples of COC described 53% of
the variance of the original data, discriminating along the axis as
a function of AMI concentration. At higher AMI concentrations, the
sample signal shifted to more negative values. Each sample’s
position took into account the contribution of all 1024 variables
(current vs potential) of each CV. However, closely analyzing the
main variables in the loading plot of PCs (Figure B), one observes that the shift of PC1 to
negative values in the samples with higher concentrations of AMI is
because of the high currents at ∼1.1 V in the forward scan
and 0.9 and 0.8 V of the reverse scan.
Figure 3
(A) Graph of PCA scores plotted with CV currents of the COC samples.
(B) Loading graph of the PCA variables, the potential applied where
the current values were obtained is highlighted. The potentials of
reverse scans are indicated with (*). (C) CVs of the COC samples recorded
with a scan rate of 50 mV s–1 using Color-ePAD with
graphite/Au, Ag/AgCl″, and Ag as working, reference, and auxiliary
electrodes, respectively. (D) Enlarged view of the central region
of the CVs shown in C. COC/AMI solutions were prepared in PBS (pH
= 2) and evaluated in the ratios: 100:0 (red), 80:20 (green), 50:50
(black), 20:80 (purple), and 0:100 (blue).
(A) Graph of PCA scores plotted with CV currents of the COC samples.
(B) Loading graph of the PCA variables, the potential applied where
the current values were obtained is highlighted. The potentials of
reverse scans are indicated with (*). (C) CVs of the COC samples recorded
with a scan rate of 50 mV s–1 using Color-ePAD with
graphite/Au, Ag/AgCl″, and Ag as working, reference, and auxiliary
electrodes, respectively. (D) Enlarged view of the central region
of the CVs shown in C. COC/AMI solutions were prepared in PBS (pH
= 2) and evaluated in the ratios: 100:0 (red), 80:20 (green), 50:50
(black), 20:80 (purple), and 0:100 (blue).Also, as the COC concentration in the sample increased, a broadening
and a slight shift to the positive potential of the AMI peaks were
observed because of possible COC adsorption on the electrode. Therefore,
an increase in current at the onset of the first anodic peak of AMI
was observed at 0.7 V in the sample 50:50 (COC/AMI mixture ratio),
which shifted the sample to positive values of PC1. Another variable
that contributed to the positive shift of PC1 was the anodic current
at 0.07 V. However, this could go unnoticed, as there is no faradaic
process involved. The samples containing high concentrations of COC
showed high currents contributing to the displacement. Similarly,
the current at 0.6 V caused a positive shift, so the sample 100:0
showed the most significant displacement among the 50:50, 80:20, and
100:0 samples. Despite the fact that samples 0:100 and 20:80 showed
high currents at 0.6 V, they were positioned on the negative side,
probably because of other variables such as those already mentioned.
Additionally, the same current at 0.6 V contributed to a positive
shift in PC2, placing the samples 0:100 and 20:80 in quadrant 1 and
100:0 in quadrant 2.Nevertheless, PC2 contributed with 20% of the data variance to
the discrimination of samples on the vertical axis. The currents at
0.5 and 0.25 V were positively displaced by the samples that presented
intense cathodic currents attributed to the reduction of the product
formed at ∼0.8 V,[39] by 0:100 and
20:80. Finally, the current at −0.1 V of the reverse scan shifted
to negative values for samples with small currents such as 50:50 and
80:20.Although the CV alone provided good discrimination of the samples
100:0, 80:20, and 50:50 even without an electrochemical signal from
COC, it was not able to discriminate the 20:80 and 0:100 samples.In order to improve the discrimination of the COC samples, the
microfluidic PAD device with colorimetric detection (ColorPAD) was
coupled to provide more information about the samples. In this sense,
PADs can easily integrate different detection techniques using only
a suitable premolded design in a software program[56] or coupling the devices in one PAD.[8,57] This
assay based on the reaction with cobalt thiocyanate can be performed
in 20 min and allow the confirmation of the presence of COC and the
quantification by the resulting color intensity, even in the presence
of a compound with potential to interfere. The complexes formed with
COC (or AMI) and the paper produced blue colors with different hues,
which turn discrimination with the naked eye difficult. Fortunately,
the paper interacts differently with each product formed and it is
possible to perform a chromatographic like separation under capillarity
flow. Therefore, we transformed the colors observed in different regions
into the RGB input data for PCA analysis. The raw data were used without
discounting the background signal.Figure A shows
the color variations of the COC samples used as the calibration data
as a function of time, where the intensity of colors was directly
related to the time and concentration of the analytes. The RGB values
were collected to compose the data matrix as a function of time and
in two different regions. In the first one, Co thiocyanate formed
a complex with COC (RGB) and in the second one with AMI (R* G* B*). Table S2 shows the RGB values for each data collection
region at different times and concentrations. Note that the red colors
R and R* were replaced by complementary blue color over time, enhancing
the values of B and B*. It is interesting to emphasize that the B
values were higher for samples containing larger concentrations of
COC, whereas B* was larger in samples with higher concentrations of
AMI. Each column of the PCA matrix was centered on its average value
to give the same weight to all variables.[32]
Figure 4
(A) Photos depicting the colorimetric detection zone of Color-ePADs
devices as a function of time and concentration of COC and AMI. (B)
PCA score graph plotted using RGB as the input data obtained in 2,
5, 10, and 20 min of analysis of the COC/AMI samples using Color-ePAD.
COC/AMI solutions were prepared in PBS (pH = 2) and evaluated in the
following ratios: 100:0 (red), 80:20 (green), 50:50 (black), 20:80
(purple), and 0:100 (blue). (C) Loading graph of the RGB variables,
which represented the time of analysis, the color of the RGB system
with respective letter and the Color-ePAD regions from where the data
were collected, the zone of COC and AMI complex formation were represented
without and with (*), respectively.
(A) Photos depicting the colorimetric detection zone of Color-ePADs
devices as a function of time and concentration of COC and AMI. (B)
PCA score graph plotted using RGB as the input data obtained in 2,
5, 10, and 20 min of analysis of the COC/AMI samples using Color-ePAD.
COC/AMI solutions were prepared in PBS (pH = 2) and evaluated in the
following ratios: 100:0 (red), 80:20 (green), 50:50 (black), 20:80
(purple), and 0:100 (blue). (C) Loading graph of the RGB variables,
which represented the time of analysis, the color of the RGB system
with respective letter and the Color-ePAD regions from where the data
were collected, the zone of COC and AMI complex formation were represented
without and with (*), respectively.According to the score plot reported in Figure S18, there is a tendency of sample discrimination, accentuated
in 5 and 10 min, where the samples were almost grouped. However, the
data were very scattered, and regions of overlap were observed. This
problem was settled by gathering the RGB values collected in each
time of analysis in a matrix, thus obtaining more precise discrimination
of the samples with greater confinement (Figure B).The PC1 and PC2 represented 41 and 18% of the variance of the 25-sample
data, respectively (Figure B). PC1 discriminated samples that contained higher concentrations
of AMI ordered in increasing concentration. In the PC2 axis, the samples
were separated in the ascending COC concentration order. Interestingly,
the variables collected in the region where the COC complex was formed
had more significant contributions to discriminate samples containing
high concentrations of AMI in the PC1 axis, as shown in the loading
graph (Figure C).
On the other hand, those collected in the region where the AMI complex
was formed contributed to discriminate samples with high COC concentrations.The discrimination of the samples was improved by combining the
electrochemical and colorimetric information obtained with Color-ePAD.
The self-scaled variables that exerted the highest weights (highlighted
above) in previous PCA analyses were gathered in a matrix. Consequently,
a score graph (Figure A) with discriminatory characteristics of the two PCAs was obtained
with better grouping of the samples, despite the unsatisfactory separation
on the PC1 axis for 20:80 and 0:100 samples because of the overlapped
electrochemical data in the PCA.
Figure 5
(A) PCA score graph combining CV currents and RGB data obtained
at 2, 5, 10, and 20 min of analysis of COC/AMI-training samples using
the Color-ePAD. COC/AMI mixtures were evaluated in the ratios: 100:0
(red), 80:20 (green), 50:50 (black), 20:80 (purple), and 0:100 (blue).
(B) PCA score graph of the same data from the previous analysis added
the synthetically simulated COC/AMI sample (stars).
(A) PCA score graph combining CV currents and RGB data obtained
at 2, 5, 10, and 20 min of analysis of COC/AMI-training samples using
the Color-ePAD. COC/AMI mixtures were evaluated in the ratios: 100:0
(red), 80:20 (green), 50:50 (black), 20:80 (purple), and 0:100 (blue).
(B) PCA score graph of the same data from the previous analysis added
the synthetically simulated COC/AMI sample (stars).Additionally, as proof-of-concept, COC samples were synthetically
simulated and they could be discriminated according to their composition
(Figure B). This dual-detection
approach seems to be more powerful to analyze the COC samples containing
a blend of adulterant compounds, the most common in real cases.[7,9,58]This work was focused on COC samples blended with AMI. However,
in the case of the presence of other adulterants such as paracetamol,
phenacetin, caffeine, procaine, and benzocaine, the resulting CV would
have a distinct pattern from those presented because of their electroactivities.[7−9] Additionally, considering the variation of current intensity related
to the analyte concentration, the samples could be discriminated according
to the adulterant content and amount. Also, amine-containing molecules
such as lidocaine can react with cobalt thiocyanate yielding a blue
precipitate (data not shown) that would interact with paper devices
differently from COC and AMI in a distinct scattering of products
along the ColorPAD, thus allowing the sample discriminations by PCA.The developed Color-ePAD could also be integrated with detection
by surface-enhanced Raman spectroscopy (SERS) because the graphite/Au
electrode had a rough Au surface appropriate for enhancement. This
allowed obtaining the spectra of other cutting agents such as the
levamisole molecule (data not shown) with the Color-ePAD. This strategy
showed to be particularly valuable for species that do not exhibit
electroactivity.[7] Therefore, the SERS spectra
can be added to the PCA data matrix, increasing the discriminatory
potential of the analysis. Although this PCA-based method does not
require trained personnel to determine the composition of a COC sample,
it depends on an extensive database that needs to be constantly fed.
Conclusions
We report a PAD manufacturing method using filter paper and regular
graphite leads modified with the Au film. The device combines electrochemical
and colorimetric detection to provide more precise information about
the COC samples adulterated with AMI. The precursor of the Au film,
AuCl4–, was synthesized on the microscale
by dissolving the Au leaf in reverse aqua regia and electrodeposited
on the graphite leads in an acidic medium at −4 V. We demonstrated
that as increasingly negative potentials were used to deposit Au,
the graphite surface coating became more effective, resulting in a
lower charge transfer resistance (3 Ω). The structure with submicrometric
particles showed edges and kinks and crystallographic gold (110) planes,
mainly, (111) and (100), which facilitated the electrochemical oxidation
of AA at least by 50 mV. The size of the Color-ePAD colorimetric detection
zone was optimized to monitor the Co thiocyanate complex with COC
and with AMI in distinct regions.The Color-ePAD device was used, as proof-of-concept, to analyze
the COC samples adulterated with AMI. The CV (i vs E) and colorimetry techniques were employed to generate
the input data for PCA analysis that classified the samples according
to the COC/AMI ratio. The method successfully classified the synthetically
simulated samples of COC based on the database assembled in this work.
Authors: Adrianne F da Silva; Tatiane S Grobério; Jorge J Zacca; Adriano O Maldaner; Jez W B Braga Journal: Forensic Sci Int Date: 2018-07-17 Impact factor: 2.395
Authors: Wilson A Ameku; Vanessa N Ataide; Eric T Costa; Larissa R Gomes; Paloma Napoleão-Pêgo; David William Provance; Thiago R L C Paixão; Maiara O Salles; Salvatore Giovanni De-Simone Journal: Biosensors (Basel) Date: 2021-11-30