Literature DB >> 23845479

Electrochemical detection of glucose from whole blood using paper-based microfluidic devices.

Julaluk Noiphung1, Temsiri Songjaroen, Wijitar Dungchai, Charles S Henry, Orawon Chailapakul, Wanida Laiwattanapaisal.   

Abstract

Electrochemical paper-based analytical devices (ePADs) with integrated plasma isolation for determination of glucose from whole blood samples have been developed. A dumbbell shaped ePAD containing two blood separation zones (VF2 membranes) with a middle detection zone was fabricated using the wax dipping method. The dumbbell shaped device was designed to separate plasma while generating homogeneous flow to the middle detection zone of the ePAD. The proposed ePADs work with whole blood samples with 24-60% hematocrit without dilution, and the plasma was completely separated within 4 min. Glucose in isolated plasma separated was detected using glucose oxidase immobilized on the middle of the paper device. The hydrogen peroxide generated from the reaction between glucose and the enzyme pass through to a Prussian blue modified screen printed electrode (PB-SPEs). The currents measured using chronoamperometry at the optimal detection potential for H2O2 (-0.1 V versus Ag/AgCl reference electrode) were proportional to glucose concentrations in the whole blood. The linear range for glucose assay was in the range 0-33.1 mM (r(2)=0.987). The coefficients of variation (CVs) of currents were 6.5%, 9.0% and 8.0% when assay whole blood sample containing glucose concentration at 3.4, 6.3, and 15.6mM, respectively. Because each sample displayed intra-individual variation of electrochemical signal, glucose assay in whole blood samples were measured using the standard addition method. Results demonstrate that the ePAD glucose assay was not significantly different from the spectrophotometric method (p=0.376, paired sample t-test, n=10).
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Electrochemical detection; Glucose; Lab-on-paper; Paper-based microfluidic devices; Wax dipping; Whole blood

Mesh:

Substances:

Year:  2013        PMID: 23845479     DOI: 10.1016/j.aca.2013.06.021

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  22 in total

1.  Inkjet printed silver electrodes on macroporous paper for a paper-based isoelectric focusing device.

Authors:  Cristina Gaspar; Tiina Sikanen; Sami Franssila; Ville Jokinen
Journal:  Biomicrofluidics       Date:  2016-12-28       Impact factor: 2.800

2.  A Paper-Based "Pop-up" Electrochemical Device for Analysis of Beta-Hydroxybutyrate.

Authors:  Chien-Chung Wang; Jonathan W Hennek; Alar Ainla; Ashok A Kumar; Wen-Jie Lan; Judy Im; Barbara S Smith; Mengxia Zhao; George M Whitesides
Journal:  Anal Chem       Date:  2016-05-31       Impact factor: 6.986

3.  4-Iodophenylboronic Acid Stabilized Gold Cluster as a New Fluorescent Chemosensor for Saccharides Based on Excimer Emission Quenching.

Authors:  Jaydev Thakarda; Pranav Dave; Sagar Bhowmik; Jasmin Kubavat; Prasenjit Maity
Journal:  J Fluoresc       Date:  2021-01-08       Impact factor: 2.217

4.  Paper-based analytical devices for point-of-care blood tests.

Authors:  Hao Yuan; Ping-Yeh Chiu; Chien-Fu Chen
Journal:  Biomicrofluidics       Date:  2021-07-23       Impact factor: 2.800

Review 5.  Paper-based analytical devices for clinical diagnosis: recent advances in the fabrication techniques and sensing mechanisms.

Authors:  Mazhar Sher; Rachel Zhuang; Utkan Demirci; Waseem Asghar
Journal:  Expert Rev Mol Diagn       Date:  2017-04       Impact factor: 5.225

6.  Development of glucose oxidase-chitosan immobilized paper biosensor using screen-printed electrode for amperometric detection of Cr(VI) in water.

Authors:  Ajinkya Dabhade; Sivaraman Jayaraman; Balasubramanian Paramasivan
Journal:  3 Biotech       Date:  2021-03-22       Impact factor: 2.406

7.  Cost-Effective and Handmade Paper-Based Immunosensing Device for Electrochemical Detection of Influenza Virus.

Authors:  Sivaranjani Devarakonda; Renu Singh; Jyoti Bhardwaj; Jaesung Jang
Journal:  Sensors (Basel)       Date:  2017-11-11       Impact factor: 3.576

8.  A Novel One-Step Fabricated, Droplet-Based Electrochemical Sensor for Facile Biochemical Assays.

Authors:  Yong Yao; Chunsun Zhang
Journal:  Sensors (Basel)       Date:  2016-08-04       Impact factor: 3.576

Review 9.  Biosensing with Paper-Based Miniaturized Printed Electrodes-A Modern Trend.

Authors:  Célia M Silveira; Tiago Monteiro; Maria Gabriela Almeida
Journal:  Biosensors (Basel)       Date:  2016-09-28

Review 10.  A Review on Microfluidic Paper-Based Analytical Devices for Glucose Detection.

Authors:  Shuopeng Liu; Wenqiong Su; Xianting Ding
Journal:  Sensors (Basel)       Date:  2016-12-08       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.