| Literature DB >> 27103080 |
Thalita G Silva1, William R de Araujo1, Rodrigo A A Muñoz2, Eduardo M Richter2, Mário H P Santana3, Wendell K T Coltro4, Thiago R L C Paixão1.
Abstract
We report the development of a simple, portable, low-cost, high-throughput visual colorimetric paper-based analytical device for the detection of procaine in seized cocaine samples. The interference of most common cutting agents found in cocaine samples was verified, and a novel electrochemical approach was used for sample pretreatment in order to increase the selectivity. Under the optimized experimental conditions, a linear analytical curve was obtained for procaine concentrations ranging from 5 to 60 μmol L(-1), with a detection limit of 0.9 μmol L(-1). The accuracy of the proposed method was evaluated using seized cocaine samples and an addition and recovery protocol.Entities:
Mesh:
Substances:
Year: 2016 PMID: 27103080 DOI: 10.1021/acs.analchem.6b00072
Source DB: PubMed Journal: Anal Chem ISSN: 0003-2700 Impact factor: 6.986