Literature DB >> 24576180

Multilayer paper-based device for colorimetric and electrochemical quantification of metals.

Poomrat Rattanarat1, Wijitar Dungchai, David Cate, John Volckens, Orawon Chailapakul, Charles S Henry.   

Abstract

The release of metals and metal-containing compounds into the environment is a growing concern in developed and developing countries, as human exposure to metals is associated with adverse health effects in virtually every organ system. Unfortunately, quantifying metals in the environment is expensive; analysis costs using certified laboratories typically exceed $100/sample, making the routine analysis of toxic metals cost-prohibitive for applications such as occupational exposure or environmental protection. Here, we report on a simple, inexpensive technology with the potential to render toxic metals detection accessible for both the developing and developed world that combines colorimetric and electrochemical microfluidic paper-based analytical devices (mPAD) in a three-dimensional configuration. Unlike previous mPADs designed for measuring metals, the device reported here separates colorimetric detection on one layer from electrochemical detection on a different layer. Separate detection layers allows different chemistries to be applied to a single sample on the same device. To demonstrate the effectiveness of this approach, colorimetric detection is shown for Ni, Fe, Cu, and Cr and electrochemical detection for Pb and Cd. Detection limits as low as 0.12 μg (Cr) were achieved on the colorimetric layer while detection limits as low as 0.25 ng (Cd and Pb) were achieved on the electrochemical layer. Selectivity for the target analytes was demonstrated for common interferences. As an example of the device utility, particulate metals collected on air sampling filters were analyzed. Levels measured with the mPAD matched known values for the certified reference samples of collected particulate matter.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24576180     DOI: 10.1021/ac5000224

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  35 in total

Review 1.  Sensitivity limits of biosensors used for the detection of metals in drinking water.

Authors:  Vangelis George Kanellis
Journal:  Biophys Rev       Date:  2018-09-17

2.  A Paper-Based "Pop-up" Electrochemical Device for Analysis of Beta-Hydroxybutyrate.

Authors:  Chien-Chung Wang; Jonathan W Hennek; Alar Ainla; Ashok A Kumar; Wen-Jie Lan; Judy Im; Barbara S Smith; Mengxia Zhao; George M Whitesides
Journal:  Anal Chem       Date:  2016-05-31       Impact factor: 6.986

Review 3.  A review on wax printed microfluidic paper-based devices for international health.

Authors:  S Altundemir; A K Uguz; K Ulgen
Journal:  Biomicrofluidics       Date:  2017-08-30       Impact factor: 2.800

4.  On-site detection of heavy metals in wastewater using a single paper strip integrated with a smartphone.

Authors:  Supattra Muhammad-Aree; Siriwan Teepoo
Journal:  Anal Bioanal Chem       Date:  2020-01-09       Impact factor: 4.142

5.  Janus electrochemistry: Simultaneous electrochemical detection at multiple working conditions in a paper-based analytical device.

Authors:  Siriwan Nantaphol; Alyssa A Kava; Robert B Channon; Takeshi Kondo; Weena Siangproh; Orawon Chailapakul; Charles S Henry
Journal:  Anal Chim Acta       Date:  2019-01-29       Impact factor: 6.558

6.  Lead toxicity in Lucilia cuprina and electrochemical analysis: a simple and low-cost alternative for forensic investigation.

Authors:  Bárbara G de O Bessa; Habdias de A Silva-Neto; Wendell K T Coltro; Thiago L Rocha; Welinton R Lopes
Journal:  Anal Bioanal Chem       Date:  2021-03-05       Impact factor: 4.142

7.  Disposable paper-based electrochemical sensor using thiol-terminated poly(2-methacryloyloxyethyl phosphorylcholine) for the label-free detection of C-reactive protein.

Authors:  Chanika Pinyorospathum; Sudkate Chaiyo; Pornpen Sae-Ung; Voravee P Hoven; Panittha Damsongsang; Weena Siangproh; Orawon Chailapakul
Journal:  Mikrochim Acta       Date:  2019-06-26       Impact factor: 5.833

8.  A versatile valving toolkit for automating fluidic operations in paper microfluidic devices.

Authors:  Bhushan J Toley; Jessica A Wang; Mayuri Gupta; Joshua R Buser; Lisa K Lafleur; Barry R Lutz; Elain Fu; Paul Yager
Journal:  Lab Chip       Date:  2015-03-21       Impact factor: 6.799

Review 9.  New Methods for Personal Exposure Monitoring for Airborne Particles.

Authors:  Kirsten A Koehler; Thomas M Peters
Journal:  Curr Environ Health Rep       Date:  2015-12

10.  Portable detection of trace metals in airborne particulates and sediments via μPADs and smartphone.

Authors:  Yuan Jia; Hui Dong; Jianping Zheng; Hao Sun
Journal:  Biomicrofluidics       Date:  2017-11-09       Impact factor: 2.800

View more