| Literature DB >> 33441322 |
Wei Wang1, Jiaqing Zhang1, Xiaoxun Gu1, Xiaoting Ruan1, Xiaoyun Chen1, Xuhua Tan1, Guangming Jin1, Lanhua Wang1, Mingguang He1,2, Nathan Congdon1,3, Zhenzhen Liu4, Lixia Luo4, Yizhi Liu1.
Abstract
BACKGROUND/AIMS: The primary objective is to quantify the lens nuclear opacity using swept-source anterior segment optical coherence tomography (SS-ASOCT) and to evaluate its correlations with Lens Opacities Classification System III (LOCS-III) system and surgical parameters. The secondary objective is to assess the diagnostic performance for hard nuclear cataract.Entities:
Keywords: lens and zonules
Mesh:
Year: 2021 PMID: 33441322 PMCID: PMC9132857 DOI: 10.1136/bjophthalmol-2020-318334
Source DB: PubMed Journal: Br J Ophthalmol ISSN: 0007-1161 Impact factor: 5.908
Figure 1Flow diagram. LOCS-III, Lens Opacities Classification System III.
Demographic and clinical features of the included patients
| Variables | All | Training set (90%) | Validating set (10%) | P value |
| No of subjects (eyes) | 1222 (1222) | 1099 (1099) | 123 (123) | |
| Age (year) | 65.25±12.75 | 65.28±12.66 | 64.92±13.64 | 0.799 |
| Female (%) | 665 (54.38) | 604 (54.99) | 60 (48.86) | 0.274 |
| Systemic hypertension (%) | 403 (33.09) | 366 (33.30) | 38 (31.15) | 0.631 |
| CDVA preoperation (logMAR) | 0.84±0.56 | 0.85±0.56 | 0.81±0.55 | 0.476 |
| IOP preoperation (mm Hg) | 11.75±3.15 | 11.72±3.16 | 12.03±3.05 | 0.302 |
| Axial length (mm) | 24.37±2.41 | 24.36±2.39 | 24.51±2.52 | 0.580 |
| Anterior chamber depth (mm) | 3.19±0.45 | 3.19±0.45 | 3.18±0.44 | 0.885 |
| Lens thickness (mm) | 4.48±0.51 | 4.48±0.50 | 4.48±0.56 | 0.915 |
| Corneal diameter (mm) | 11.84±0.54 | 11.83±0.54 | 11.90±0.49 | 0.278 |
| Total ultrasonic time (seconds) | 53.24±99.64 | 54.26±104.53 | 44.14±31.86 | 0.317 |
| Cumulative dissipated energy (%-seconds) | 1165.27±1885.04 | 1200.18±1967.23 | 856.26±808.25 | 0.072 |
| UDVA postoperation (logMAR) | 0.30±0.57 | 0.31±0.58 | 0.27±0.48 | 0.520 |
| IOP postoperation (mm Hg) | 14.14±4.78 | 14.11±4.70 | 14.38±5.43 | 0.597 |
Data were presented as mean±SD or number (%).
CDVA, corrected distance visual acuity; IOP, intraocular pressure; logMAR, logarithmic minimal angle resolution; UDVA, uncorrected distance visual acuity.
Figure 2Scatter plots showing the correlations of SS-ASOCT nuclear density quantitated by ImageJ software in pixel intensity units with LOCS-III scores (n=1099). (A) Maximum nuclear density versus NC score; (B) maximum nuclear density versus no score; (C) average nuclear density versus NC score; (D) average nuclear density versus no score. NC, nuclear colour; NO, nuclear opalescence; LOCS-III, Lens Opacities Classification System III; SS-ASOCT, swept-source anterior segment optical coherence tomography.
Spearman’s correlation analyses of LOCS-III scores and nuclear density measured by SS-ASOCT images with visual acuity and phacoemulsification parameters in training dataset (n=1099)
| NO score (LOCS-III) | NC scores (LOCS-III) | Average nuclear density (SS-OCT) | Maximum nuclear density (SS-OCT) | |||||
| R | P value* | R | P value* | R | P value* | R | P value* | |
| CDVA at baseline (logMAR) | 0.2623 |
| 0.2655 |
| 0.3131 |
| 0.2445 |
|
| UDVA at 1 week postoperatively (logMAR) | 0.0782 |
| 0.0605 | 0.096 | 0.1198 |
| 0.1945 |
|
| Total US time (seconds, log scale) | 0.2965 |
| 0.3015 |
| 0.3481 |
| 0.2347 |
|
| CDE (%-seconds, log scale) | 0.3734 |
| 0.3784 |
| 0.4265 |
| 0.2439 |
|
*Bold indicates statistically significant.
CDE, cumulative dissipated energy; CDVA, corrected distance visual acuity; LOCS-III, Lens Opacities Classification System III; logMAR, logarithmic minimal angle resolution; NC, nuclear colour; NO, nuclear opalescence; SS-ASOCT, swept-source anterior segment optical coherence tomography; UDVA, uncorrected distance visual acuity; US, ultrasonic.
Figure 3Receiver operating characteristic (ROC) curve and calibration curve for diagnosis of hard nuclear cataract (LOCS-III NO score ≥5.0) in training dataset (n=1099). (A) The ROC curve showing excellent discriminative power of AND and MND for diagnosing hard nuclear cataract. (B) The calibration plot showed good calibration between the observed and predicted proportion of hard nuclear cataract. AND, average nuclear density; AUC, area under the curve; LOCS-III, Lens Opacities Classification System III; MND, maximum nuclear density; NO, nuclear opalescence.