Literature DB >> 29335103

New objective lens density quantification method using swept-source optical coherence tomography technology: Comparison with existing methods.

Christophe Panthier1, Justine Burgos1, Helene Rouger1, Alain Saad1, Damien Gatinel2.   

Abstract

PURPOSE: To assess a new objective cataract grading method based on lens densitometry on swept-source optical coherence tomography (SS-OCT) scans provided by the IOLMaster 700. SETTINGS: Rothschild Foundation, Paris, France.
DESIGN: Prospective case series.
METHODS: All patients consulting for cataract evaluation who provided their consent to participate in the study were included. A history of eye surgery, corneal or retinal disorders, and ocular dryness were exclusion criteria. The average lens densitometry was measured with SS-OCT scans using ImageJ software. The ocular scatter index (OSI) measured with a double-pass aberrometer (Optical Quality Analysis System), the Pentacam nucleus staging (hereafter referred to as nuclear staging) score, and mean nuclear staging were also measured and compared with the mean lens densitometry.
RESULTS: One hundred ten eyes (51 with cataract and 59 controls) were included. The average lens densitometry measurements were repeatable (P = .99, analysis of variance). The repeatability limit was 2.50 pixel units. The average lens density was correlated with the OSI (r2 = 0.52, P < .01), nuclear staging score (r2 = 0.75, P < .01), and mean nuclear staging (r2 = 0.41, P < .01). An average lens density greater than 82.9 pixel units was the cutoff threshold for cataract, with a sensitivity of 73.9% and a specificity of 91.2%.
CONCLUSIONS: The average lens density measured by SS-OCT was a repeatable and reliable objective cataract grading method. It was correlated with OSI measurement. If the average lens density was greater than 82.9 pixel units and the patient reported visual impairment, cataract surgery might be discussed.
Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Year:  2017        PMID: 29335103     DOI: 10.1016/j.jcrs.2017.09.028

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  7 in total

1.  Three-dimensional visualization of opacifications in the murine crystalline lens by in vivo optical coherence tomography.

Authors:  Pablo Eugui; Danielle J Harper; Stefan Kummer; Antonia Lichtenegger; Johanna Gesperger; Tanja Himmel; Marco Augustin; Conrad W Merkle; Martin Glösmann; Bernhard Baumann
Journal:  Biomed Opt Express       Date:  2020-03-19       Impact factor: 3.732

2.  Axial Length Change in Pseudophakic Eyes Measured by IOLMaster 700.

Authors:  Jiaqing Zhang; Zhenzhen Liu; Xiaozhang Qiu; Ling Jin; Lanhua Wang; Guangming Jin; Wei Wang; Xuhua Tan; Lixia Luo; Yizhi Liu
Journal:  Transl Vis Sci Technol       Date:  2021-05-03       Impact factor: 3.283

3.  Objective quantification of lens nuclear opacities using swept-source anterior segment optical coherence tomography.

Authors:  Wei Wang; Jiaqing Zhang; Xiaoxun Gu; Xiaoting Ruan; Xiaoyun Chen; Xuhua Tan; Guangming Jin; Lanhua Wang; Mingguang He; Nathan Congdon; Zhenzhen Liu; Lixia Luo; Yizhi Liu
Journal:  Br J Ophthalmol       Date:  2021-01-13       Impact factor: 5.908

4.  Objective quantification and spatial mapping of cataract with a Shack-Hartmann wavefront sensor.

Authors:  Csaba Tamás Holló; Kata Miháltz; Máté Kurucz; Anita Csorba; Kinga Kránitz; Illés Kovács; Zoltán Zsolt Nagy; Gábor Erdei
Journal:  Sci Rep       Date:  2020-07-28       Impact factor: 4.379

5.  Reliability of a New Swept-Source Optical Coherence Tomography Biometer in Healthy Children, Adults, and Cataract Patients.

Authors:  Jinhai Huang; Yuyu Zhao; Giacomo Savini; Guanshun Yu; Jinjin Yu; Zhongxing Chen; Ruixue Tu; Yune Zhao
Journal:  J Ophthalmol       Date:  2020-05-15       Impact factor: 1.909

Review 6.  Towards a Connected Mobile Cataract Screening System: A Future Approach.

Authors:  Wan Mimi Diyana Wan Zaki; Haliza Abdul Mutalib; Laily Azyan Ramlan; Aini Hussain; Aouache Mustapha
Journal:  J Imaging       Date:  2022-02-10

7.  Assessing the correlation between swept-source optical coherence tomography lens density pattern analysis and best-corrected visual acuity in patients with cataracts.

Authors:  Hugo Bourdon; Liem Trinh; Mathieu Robin; Christophe Baudouin
Journal:  BMJ Open Ophthalmol       Date:  2021-05-13
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.