Literature DB >> 33432526

Accuracy of guided surgery using the silicon impression and digital impression method for the mandibular free end: a comparative study.

Koudai Nagata1, Kei Fuchigami1,2, Noriyuki Hoshi2, Mihoko Atsumi2, Katsuhiko Kimoto2, Hiromasa Kawana3.   

Abstract

BACKGROUND: Implant treatment using guided surgery is becoming widespread in clinical dental practice. Furthermore, the development of digital technology has enabled the use of intraoral scanners (IOSs) to fabricate surgical guide plates. The objective of this study was to compare the accuracy of guided surgery using the silicone impression method with a three-dimensional (3D) scanner and the digital impression method with IOS for one side of the mandibular free end. In addition, we compared the accuracy of tooth-supported vs tooth/mucosa-supported surgical guide plates.
RESULTS: The accuracy of the tooth-supported surgical guide plate using the new IOS method instead of the method of obtaining impressions with conventional silicone resulted in better measurements of 3D deviation at the crest, 3D deviation at the apex, and angular deviation. In terms of the accuracy of the tooth/mucosa-supported surgical guide plate, there were no significant differences in all measurements. The surgical guide plate using an IOS and the tooth/mucosa-supported surgical guide plate may enable more accurate guided surgery.
CONCLUSION: Tooth/mucosa-supported guided surgery involving preparation with an IOS may result in more accurate implant surgery.

Entities:  

Keywords:  Computer-aided surgery; Dental implant; Digital workflow; Guided surgery; Implant impression; Intraoral scanner

Year:  2021        PMID: 33432526      PMCID: PMC7801556          DOI: 10.1186/s40729-020-00281-z

Source DB:  PubMed          Journal:  Int J Implant Dent        ISSN: 2198-4034


  19 in total

1.  Accuracy of computer-aided oral implant surgery: a clinical and radiographic study.

Authors:  Francesco Valente; Guido Schiroli; Andrea Sbrenna
Journal:  Int J Oral Maxillofac Implants       Date:  2009 Mar-Apr       Impact factor: 2.804

2.  The accuracy of single-tooth implants placed using fully digital-guided surgery and freehand implant surgery.

Authors:  Palita Smitkarn; Keskanya Subbalekha; Nikos Mattheos; Atiphan Pimkhaokham
Journal:  J Clin Periodontol       Date:  2019-07-19       Impact factor: 8.728

3.  Accuracy of stereolithographically printed digital models compared to plaster models.

Authors:  Leonardo Tavares Camardella; Oswaldo V Vilella; Marleen M van Hezel; Karel H Breuning
Journal:  J Orofac Orthop       Date:  2017-03-30       Impact factor: 1.938

4.  The influence of guided sleeve height, drilling distance, and drilling key length on the accuracy of static Computer-Assisted Implant Surgery.

Authors:  Karim El Kholy; Simone F M Janner; Martin Schimmel; Daniel Buser
Journal:  Clin Implant Dent Relat Res       Date:  2018-12-27       Impact factor: 3.932

5.  Static computer-aided implant surgery (s-CAIS) analysing patient-reported outcome measures (PROMs), economics and surgical complications: A systematic review.

Authors:  Tim Joda; Wiebe Derksen; Julia Gabriela Wittneben; Sebastian Kuehl
Journal:  Clin Oral Implants Res       Date:  2018-10       Impact factor: 5.977

6.  Factors influencing transfer accuracy of cone beam CT-derived template-based implant placement.

Authors:  Alexandra Behneke; Matthias Burwinkel; Nikolaus Behneke
Journal:  Clin Oral Implants Res       Date:  2011-10-24       Impact factor: 5.977

Review 7.  Computer technology applications in surgical implant dentistry: a systematic review.

Authors:  Ali Tahmaseb; Daniel Wismeijer; Wim Coucke; Wiebe Derksen
Journal:  Int J Oral Maxillofac Implants       Date:  2014       Impact factor: 2.804

8.  Accuracy of a new elastomeric impression material for complete-arch dental implant impressions.

Authors:  Mirza R Baig; Muaiyed M Buzayan; Norsiah Yunus
Journal:  J Investig Clin Dent       Date:  2018-01-18

9.  Validity of Intraoral Scans Compared with Plaster Models: An In-Vivo Comparison of Dental Measurements and 3D Surface Analysis.

Authors:  Fan Zhang; Kyung-Jin Suh; Kyung-Min Lee
Journal:  PLoS One       Date:  2016-06-15       Impact factor: 3.240

10.  Accuracy of implant surgery with surgical guide by inexperienced clinicians: an in vitro study.

Authors:  Takeshi Toyoshima; Hideaki Tanaka; Masanori Sasaki; Eiji Ichimaru; Yasushi Naito; Yasuyuki Matsushita; Kiyoshi Koyano; Seiji Nakamura
Journal:  Clin Exp Dent Res       Date:  2015-07-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.