Literature DB >> 29349910

Accuracy of a new elastomeric impression material for complete-arch dental implant impressions.

Mirza R Baig1, Muaiyed M Buzayan2, Norsiah Yunus3.   

Abstract

AIM: The aim of the present study was to assess the accuracy of multi-unit dental implant casts obtained from two elastomeric impression materials, vinyl polyether silicone (VPES) and polyether (PE), and to test the effect of splinting of impression copings on the accuracy of implant casts.
METHODS: Forty direct impressions of a mandibular reference model fitted with six dental implants and multibase abutments were made using VPES and PE, and implant casts were poured (N = 20). The VPES and PE groups were split into four subgroups of five each, based on splinting type: (a) no splinting; (b) bite registration polyether; (c) bite registration addition silicone; and (d) autopolymerizing acrylic resin. The accuracy of implant-abutment replica positions was calculated on the experimental casts, in terms of interimplant distances in the x, y, and z-axes, using a coordinate measuring machine; values were compared with those measured on the reference model. Data were analyzed using non-parametrical Kruskal-Wallis and Mann-Whitney tests at α = .05.
RESULTS: The differences between the two impression materials, VPES and PE, regardless of splinting type, were not statistically significant (P>.05). Non-splinting and splinting groups were also not significantly different for both PE and VPES (P>.05).
CONCLUSIONS: The accuracy of VPES impression material seemed comparable with PE for multi-implant abutment-level impressions. Splinting had no effect on the accuracy of implant impressions.
© 2018 John Wiley & Sons Australia, Ltd.

Entities:  

Keywords:  cast; dental implant; elastomeric impression material; splinting; vinyl polyether silicone

Mesh:

Substances:

Year:  2018        PMID: 29349910     DOI: 10.1111/jicd.12320

Source DB:  PubMed          Journal:  J Investig Clin Dent        ISSN: 2041-1618


  3 in total

Review 1.  Digital versus conventional full-arch impressions in linear and 3D accuracy: a systematic review and meta-analysis of in vivo studies.

Authors:  Lin Kong; Yabing Li; Zhijian Liu
Journal:  Clin Oral Investig       Date:  2022-07-04       Impact factor: 3.606

2.  Accuracy of guided surgery using the silicon impression and digital impression method for the mandibular free end: a comparative study.

Authors:  Koudai Nagata; Kei Fuchigami; Noriyuki Hoshi; Mihoko Atsumi; Katsuhiko Kimoto; Hiromasa Kawana
Journal:  Int J Implant Dent       Date:  2021-01-12

3.  Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants.

Authors:  Rohini Rajendran; N Gopi Chander; Kuttae Vishwanathan Anitha; Balasubramanian Muthukumar
Journal:  Eur Oral Res       Date:  2021-05-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.