Literature DB >> 3341177

Doppler evaluation of bioprosthetic and mechanical aortic valves: data from four models in 107 stable, ambulatory patients.

M L Ramirez1, M Wong, N Sadler, P M Shah.   

Abstract

To test the applicability of Doppler ultrasound in the evaluation of prosthetic valve function, 107 patients with normal ejection fractions in whom Starr-Edwards, Björk-Shiley, Carpentier-Edwards, and Hancock models had been implanted in the aortic position were examined. Maximal transvalvular velocity was recorded by non-imaging continuous wave Doppler ultrasound. Means of maximal velocities by model and size ranged from less than 2 to 4 m/sec. The Starr-Edwards valve showed the highest velocities, the Björk-Shiley the lowest, and the bioprosthetic models showed velocities in between. A significant inverse relation between velocity and size, and standard deviations averaging +/- 14% enabled the technique to measure differences between sizes of the same model. Aortic regurgitation was detected in 24% of the patients. This study, conducted in well and stable patients, established values for maximal velocity across normally functioning aortic mechanical and tissue prostheses of different models and sizes. The intersubject variability was relatively small which, together with a previously shown minimal intrasubject variability, was testimony to a methodology that should prove useful in longitudinal postoperative evaluations.

Entities:  

Mesh:

Year:  1988        PMID: 3341177     DOI: 10.1016/0002-8703(88)90490-5

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  4 in total

1.  Echocardiographic assessment of artificial heart valves: British Society of Echocardiography position paper.

Authors:  J Chambers; A Fraser; P Lawford; P Nihoyannopoulos; I Simpson
Journal:  Br Heart J       Date:  1994-04

2.  Four year follow up of aortic valve replacement for isolated aortic stenosis: a link between reduction in pressure overload, regression of left ventricular hypertrophy, and diastolic function.

Authors:  I Ikonomidis; A Tsoukas; F Parthenakis; A Gournizakis; A Kassimatis; L Rallidis; P Nihoyannopoulos
Journal:  Heart       Date:  2001-09       Impact factor: 5.994

Review 3.  Diagnostic evaluation of left-sided prosthetic heart valve dysfunction.

Authors:  Jesse Habets; Ricardo P Budde; Petr Symersky; Renee B van den Brink; Bas A de Mol; Willem P Mali; Lex A van Herwerden; Steven A Chamuleau
Journal:  Nat Rev Cardiol       Date:  2011-05-17       Impact factor: 32.419

4.  Colour flow Doppler mapping in the assessment of prosthetic valve regurgitation.

Authors:  J Chambers; M Monaghan; G Jackson
Journal:  Br Heart J       Date:  1989-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.