Literature DB >> 33410291

Delayed Presentation of Thoracic Aortic Pseudoaneurysm Following Pedicle Screw Implantation: A Case Report.

Li-di Liu1, Xin Hong2, Jiang-Bi Li1, Shao-Kun Zhang1.   

Abstract

BACKGROUND: Pedicle screw insertion has been known to have several complications even in the most skilled surgical hands. However, injury to the thoracic aorta during pedicle screw insertion is rare, delayed presentation secondary to pseudoaneurysm is even rarer, the pseudoaneurysm formation caused by a series of malpositioned pedicle screws has perhaps not been reported so far. CASE
PRESENTATION: In this paper, we report here a case in which inadvertent injury to the thoracic aorta resulted in pseudoaneurysm, its manifestation was initially vague, resulting in a delayed diagnosis. Delayed aortic pseudoaneurysm or injury can be asymptomatic for a long time. Patients with renewed or continued back pain should alert orthopaedic surgeons regarding the possibility of pseudoaneurysms, regardless of the period that has elapsed after pedicle screw implantation.
© 2021 The Authors. Orthopaedic Surgery published by Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

Entities:  

Keywords:  Aortic injury; Malposition; Pedicle screw implants; Pseudoaneurysm formation; Thoracic and lumbar spine

Year:  2021        PMID: 33410291      PMCID: PMC7862157          DOI: 10.1111/os.12793

Source DB:  PubMed          Journal:  Orthop Surg        ISSN: 1757-7853            Impact factor:   2.071


  17 in total

Review 1.  Delayed presentation of aortic injury by pedicle screws: report of two cases and review of the literature.

Authors:  Stavros K Kakkos; Alexander D Shepard
Journal:  J Vasc Surg       Date:  2008-02-01       Impact factor: 4.268

2.  Delayed perforation of the aorta by a thoracic pedicle screw.

Authors:  Bernd Wegener; Christof Birkenmaier; Andreas Fottner; Volkmar Jansson; Hans Roland Dürr
Journal:  Eur Spine J       Date:  2008-07-10       Impact factor: 3.134

Review 3.  Combined thoracic endovascular aortic repair and neurosurgical intervention for injury due to posterior spine surgery.

Authors:  Amedeo Carmignani; Salvatore Lentini; Edvige Acri; Giovanni Vazzana; Mauro Campello; Pietro Volpe; Ignazio E Acri; Francesco Spinelli
Journal:  J Card Surg       Date:  2013-01-07       Impact factor: 1.620

4.  Delayed aortic rupture caused by an implanted anterior spinal device. Case report.

Authors:  T Ohnishi; M Neo; M Matsushita; M Komeda; T Koyama; T Nakamura
Journal:  J Neurosurg       Date:  2001-10       Impact factor: 5.115

5.  Delayed presentation of a thoracic aortic injury with a vertebral pedicle screw.

Authors:  Antonio Freyrie; Alessandro Gasbarrini; Christiano Esteves Simoes; Enrico Gallitto; Mauro Gargiulo
Journal:  Ann Vasc Surg       Date:  2013-03-29       Impact factor: 1.466

6.  Aortoiliac vascular injuries after misplacement of fixation screws.

Authors:  Jorge E Lopera; Carlos S Restrepo; Arturo Gonzales; Clayton K Trimmer; Frank Arko
Journal:  J Trauma       Date:  2010-10

7.  Thoracic vertebral screw impingement on the aorta in an in vivo bovine model.

Authors:  Fran D Faro; Christine L Farnsworth; Gary S Shapiro; Fazir Mohamad; Klane K White; Eric Breisch; Andrew T Mahar; Tucker Tomlinson; Maneesh Bawa; Mark Gomez; Peter O Newton
Journal:  Spine (Phila Pa 1976)       Date:  2005-11-01       Impact factor: 3.468

8.  A retrospective analysis of pedicle screws in contact with the great vessels.

Authors:  Kenneth C Foxx; Roy C Kwak; Jonathan M Latzman; Uzma Samadani
Journal:  J Neurosurg Spine       Date:  2010-09

9.  Strategies for prevention and operative treatment of aortic lesions related to spinal interventions.

Authors:  Reinhard Kopp; Rudolph Beisse; Rolf Weidenhagen; Stefan Piltz; Stefan Hauck; Christoph R Becker; Oliver Pieske; Volker Bühren; Karl Walter Jauch; Lutz Lauterjung
Journal:  Spine (Phila Pa 1976)       Date:  2007-12-01       Impact factor: 3.468

10.  Thoracic aortic stent-graft placement for safe removal of a malpositioned pedicle screw.

Authors:  Hong-Tao Hu; Ji Hoon Shin; Jae-Yeon Hwang; Young Jun Cho; Gi-Young Ko; Hyun-Ki Yoon
Journal:  Cardiovasc Intervent Radiol       Date:  2009-12-24       Impact factor: 2.740

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.