Iatrogenic aortic injuries by pedicle screws are rare but serious complications of spinal fixation surgery. We report the case of a 55-year-old man who underwent surgical correction of traumatic thoracic vertebral fractures at another institution. At 6-month follow-up, computed tomography revealed a nonhealing of the fractures, and a T4 misplaced pedicle screw penetrating the descending thoracic aorta. The patient underwent open aortic repair associated with the anterior vertebral column reconstruction and posterior arthrodesis revision by a vascular and orthopedic surgery team simultaneously.Entities:
Mesh:
Year: 2013 PMID: 23541778 DOI: 10.1016/j.avsg.2012.07.025