Literature DB >> 19147898

Fluoroscopic tumor tracking for image-guided lung cancer radiotherapy.

Tong Lin1, Laura I Cerviño, Xiaoli Tang, Nuno Vasconcelos, Steve B Jiang.   

Abstract

Accurate lung tumor tracking in real time is a keystone to image-guided radiotherapy of lung cancers. Existing lung tumor tracking approaches can be roughly grouped into three categories: (1) deriving tumor position from external surrogates; (2) tracking implanted fiducial markers fluoroscopically or electromagnetically; (3) fluoroscopically tracking lung tumor without implanted fiducial markers. The first approach suffers from insufficient accuracy, while the second may not be widely accepted due to the risk of pneumothorax. Previous studies in fluoroscopic markerless tracking are mainly based on template matching methods, which may fail when the tumor boundary is unclear in fluoroscopic images. In this paper we propose a novel markerless tumor tracking algorithm, which employs the correlation between the tumor position and surrogate anatomic features in the image. The positions of the surrogate features are not directly tracked; instead, we use principal component analysis of regions of interest containing them to obtain parametric representations of their motion patterns. Then, the tumor position can be predicted from the parametric representations of surrogates through regression. Four regression methods were tested in this study: linear and two-degree polynomial regression, artificial neural network (ANN) and support vector machine (SVM). The experimental results based on fluoroscopic sequences of ten lung cancer patients demonstrate a mean tracking error of 2.1 pixels and a maximum error at a 95% confidence level of 4.6 pixels (pixel size is about 0.5 mm) for the proposed tracking algorithm.

Entities:  

Mesh:

Year:  2009        PMID: 19147898     DOI: 10.1088/0031-9155/54/4/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  26 in total

1.  Dynamic dual-energy chest radiography: a potential tool for lung tissue motion monitoring and kinetic study.

Authors:  Tong Xu; Justin L Ducote; Jerry T Wong; Sabee Molloi
Journal:  Phys Med Biol       Date:  2011-02-01       Impact factor: 3.609

2.  A novel phantom for characterization of dual energy imaging using an on-board imaging system.

Authors:  Maksat Haytmyradov; Rakesh Patel; Hassan Mostafavi; Murat Surucu; Adam Wang; Matthew M Harkenrider; John C Roeske
Journal:  Phys Med Biol       Date:  2019-01-21       Impact factor: 3.609

3.  Implementation and experimental results of 4D tumor tracking using robotic couch.

Authors:  I Buzurovic; Y Yu; M Werner-Wasik; T Biswas; P R Anne; A P Dicker; T K Podder
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

4.  Context region discovery for automatic motion compensation in fluoroscopy.

Authors:  Yin Xia; Sarfaraz Hussein; Vivek Singh; Matthias John; Ying Wu; Terrence Chen
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-03-26       Impact factor: 2.924

5.  A Study on Stereoscopic X-ray Imaging Data Set on the Accuracy of Real-Time Tumor Tracking in External Beam Radiotherapy.

Authors:  Ahmad Esmaili Torshabi; Leila Ghorbanzadeh
Journal:  Technol Cancer Res Treat       Date:  2016-07-08

6.  Real-time soft tissue motion estimation for lung tumors during radiotherapy delivery.

Authors:  Joerg Rottmann; Paul Keall; Ross Berbeco
Journal:  Med Phys       Date:  2013-09       Impact factor: 4.071

7.  Evaluation of template matching for tumor motion management with cine-MR images in lung cancer patients.

Authors:  Xiutao Shi; Tejan Diwanji; Karen E Mooney; Jolinta Lin; Steven Feigenberg; Warren D D'Souza; Nilesh N Mistry
Journal:  Med Phys       Date:  2014-05       Impact factor: 4.071

8.  2D/4D marker-free tumor tracking using 4D CBCT as the reference image.

Authors:  Mengjiao Wang; Gregory C Sharp; Simon Rit; Vivien Delmon; Guangzhi Wang
Journal:  Phys Med Biol       Date:  2014-04-08       Impact factor: 3.609

9.  Robust fluoroscopic tracking of fiducial markers: exploiting the spatial constraints.

Authors:  Rui Li; Gregory Sharp
Journal:  Phys Med Biol       Date:  2013-02-26       Impact factor: 3.609

10.  A new scheme for real-time high-contrast imaging in lung cancer radiotherapy: a proof-of-concept study.

Authors:  Hao Yan; Zhen Tian; Yiping Shao; Steve B Jiang; Xun Jia
Journal:  Phys Med Biol       Date:  2016-03-04       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.