Assessment of radio-frequency heating of a parallel transmit coil in a phantom using multi-echo proton resonance frequency shift thermometry.

Hongbae Jeong1, Matthew C Restivo2, Peter Jezzard3, Aaron T Hess4.   

Abstract

We propose a workflow for validating parallel transmission (pTx) radio-frequency (RF) magnetic field heating patterns using Proton-Resonance Frequency shift (PRF)-based MR thermometry. Electromagnetic (EM) and thermal simulations of a 7 T 8-channel dipole coil were done using commercially available software (Sim4Life) to assess RF heating. The fabrication method for a phantom with electrical properties matched to human tissue is also described, along with methods for its electrical and thermal characterisation. Energy was deposited to specific transmit channels, whilst acquiring 3D PRF data using a pair of interleaved RF shim transmit modes. A multi-echo readout and pre-scan stabilisation protocol were used for increased sensitivity and to correct for measurement-to-measurement instabilities. The electrical properties of the phantom were found to be within 10% of the intended values. Adoption of a 14-min stabilisation scan gave sufficient suppression of any evolving background spatial variation in the B0 field to achieve <0.001 °C/mm thermometry drift over 10 min of subsequent scanning. Using two RF shim transmit modes enabled full phantom coverage and combining multiple echo times enabled a 13-54% improvement in the RMSE sensitivity to temperature changes. Combining multiple echoes reduced the peak RMSE by 45% and visually reduced measurement-to-measurement instabilities. A reference fibre optic probe showed temperature deviations from the PRF-estimated temperature to be smaller than 0.5 °C. Given the importance of RF safety in pTx applications, this workflow enables accurate validation of RF heating simulations with minimal additional hardware requirements.
Copyright © 2020 The Author(s). Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  MRI temperature measurement; Parallel transmission; RF safety and SAR; RF transmit coils; pTx

Mesh:

Substances:

Year:  2020        PMID: 33359425      PMCID: PMC7889491          DOI: 10.1016/j.mri.2020.12.013

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  44 in total

1.  Transmit SENSE.

Authors:  Ulrich Katscher; Peter Börnert; Christoph Leussler; Johan S van den Brink
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

2.  Patient safety concept for multichannel transmit coils.

Authors:  Frank Seifert; Gerd Wübbeler; Sven Junge; Bernd Ittermann; Herbert Rinneberg
Journal:  J Magn Reson Imaging       Date:  2007-11       Impact factor: 4.813

3.  SAR simulations for high-field MRI: how much detail, effort, and accuracy is needed?

Authors:  S Wolf; D Diehl; M Gebhardt; J Mallow; O Speck
Journal:  Magn Reson Med       Date:  2012-05-18       Impact factor: 4.668

4.  MRI thermometry in phantoms by use of the proton resonance frequency shift method: application to interstitial laser thermotherapy.

Authors:  J Olsrud; R Wirestam; S Brockstedt; A M Nilsson; K G Tranberg; F Ståhlberg; B R Persson
Journal:  Phys Med Biol       Date:  1998-09       Impact factor: 3.609

5.  The fractionated dipole antenna: A new antenna for body imaging at 7 Tesla.

Authors:  Alexander J E Raaijmakers; Michel Italiaander; Ingmar J Voogt; Peter R Luijten; Johannes M Hoogduin; Dennis W J Klomp; Cornelis A T van den Berg
Journal:  Magn Reson Med       Date:  2015-05-02       Impact factor: 4.668

6.  Model predictive filtering MR thermometry: Effects of model inaccuracies, k-space reduction factor, and temperature increase rate.

Authors:  Henrik Odéen; Nick Todd; Christopher Dillon; Allison Payne; Dennis L Parker
Journal:  Magn Reson Med       Date:  2015-02-25       Impact factor: 4.668

7.  Measurement of SAR-induced temperature increase in a phantom and in vivo with comparison to numerical simulation.

Authors:  Sukhoon Oh; Yeun-Chul Ryu; Giuseppe Carluccio; Christopher T Sica; Christopher M Collins
Journal:  Magn Reson Med       Date:  2013-06-26       Impact factor: 4.668

8.  Improving peak local SAR prediction in parallel transmit using in situ S-matrix measurements.

Authors:  Matthew Restivo; Alexander Raaijmakers; Cornelis van den Berg; Peter Luijten; Hans Hoogduin
Journal:  Magn Reson Med       Date:  2016-05-13       Impact factor: 4.668

9.  An anatomically realistic temperature phantom for radiofrequency heating measurements.

Authors:  Nadine N Graedel; Jonathan R Polimeni; Bastien Guerin; Borjan Gagoski; Giorgio Bonmassar; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2014-02-18       Impact factor: 4.668

10.  Design and evaluation of a hybrid radiofrequency applicator for magnetic resonance imaging and RF induced hyperthermia: electromagnetic field simulations up to 14.0 Tesla and proof-of-concept at 7.0 Tesla.

Authors:  Lukas Winter; Celal Özerdem; Werner Hoffmann; Davide Santoro; Alexander Müller; Helmar Waiczies; Reiner Seemann; Andreas Graessl; Peter Wust; Thoralf Niendorf
Journal:  PLoS One       Date:  2013-04-22       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.