Literature DB >> 33348644

One Abutment One Time: A Multicenter, Prospective, Controlled, Randomized Study.

José Vicente Ríos-Santos1, Gregorio Tello-González1, Pedro Lázaro-Calvo1, Francisco Javier Gil Mur2, Blanca Ríos-Carrasco1, Ana Fernández-Palacín3, Mariano Herrero-Climent4.   

Abstract

Aim: (PRIMARY) Assess the changes in bone level (6 and 12 months after implant placement) between the test (definitive abutment (DEF)) and control (healing abutment (HEA)) groups. (SECONDARY) Assess the changes in bone level (6 and 12 months after implant placement) between the 1 mm high abutment group and 2 mm abutment group. Evaluate changes in implant stability recorded with analysis of the resonance frequency (RFA) Osstell system, at 6 and 12 months after implant placement, between the control group (HEA) and test (DEF). For the DEF group, the abutment was placed at the time of the surgery and was never removed. For the HEA group, the abutment was removed three times during the manufacture of the crowns. The abutments used were 1 mm high (Subgroup A) and 2 mm high (Subgroup B). Materials and methods: A total of 147 patients were selected between 54.82 ± 11.92 years old. After implant placement, patients were randomly distributed in the DEF and HEA group. After the implant placement, a periapical radiograph was taken to assess the peri-implant bone level; the same procedure was carried out 6 and 12 months post-placement. To compare the qualitative variables between the groups (HEA/DEF), the Chi-square test was used; for quantitative (MANOVA).
Results: After a year, the accumulated bone loss was 0.48 ± 0.71 mm for the HEA group and 0.36 ± 0.79 mm for the DEF group, without statistical significance. Differences were only found due to timing (time) between 0 and 6 months (=0.001) and 0 and 12 months (0.001), with no differences attributable to the study groups (DEF and HEA). The accumulated bone loss (1 year) was 0.45 ± 0.78 mm for the 1 mm abutment group and 0.41 ± 0.70 mm for the 2 mm abutment group (p = 0.02). No differences were observed in implant stability between groups. Conclusions: The "One Abutment-One Time" concept does not reduce peri-implant bone loss compared to the connection-disconnection technique. The height of the abutment does influence bone loss: the higher the abutment, the lower the bone loss.

Entities:  

Keywords:  connection and disconnection abutment; dental implants; implant bone loss; implant collar; implant neck; implant-abutment connections; marginal bone level

Mesh:

Year:  2020        PMID: 33348644      PMCID: PMC7765846          DOI: 10.3390/ijerph17249453

Source DB:  PubMed          Journal:  Int J Environ Res Public Health        ISSN: 1660-4601            Impact factor:   3.390


  39 in total

1.  Influence of two different machined-collar heights on crestal bone loss.

Authors:  Mariano Herrero-Climent; Manuel María Romero Ruiz; Carmen María Díaz-Castro; Pedro Bullón; Jose Vincente Ríos-Santos
Journal:  Int J Oral Maxillofac Implants       Date:  2014 Nov-Dec       Impact factor: 2.804

2.  Immediate positioning of definitive abutments versus repeated abutment replacements in immediately loaded implants: effects on bone healing at the 1-year follow-up of a multicentre randomised controlled trial.

Authors:  Tommaso Grandi; Paolo Guazzi; Rawad Samarani; Giovanna Garuti
Journal:  Eur J Oral Implantol       Date:  2012       Impact factor: 3.123

Review 3.  Soft tissue sealing around dental implants based on histological interpretation.

Authors:  Ikiru Atsuta; Yasunori Ayukawa; Ryosuke Kondo; Wakana Oshiro; Yuri Matsuura; Akihiro Furuhashi; Yoshihiro Tsukiyama; Kiyoshi Koyano
Journal:  J Prosthodont Res       Date:  2015-12-23       Impact factor: 4.642

4.  Clinical criteria for the definition of "established periodontitis".

Authors:  E E Machtei; L A Christersson; S G Grossi; R Dunford; J J Zambon; R J Genco
Journal:  J Periodontol       Date:  1992-03       Impact factor: 6.993

Review 5.  Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications.

Authors:  Lars Sennerby; Neil Meredith
Journal:  Periodontol 2000       Date:  2008       Impact factor: 7.589

6.  The effect of one-time abutment placement on interproximal bone levels and peri-implant soft tissues: a prospective randomized clinical trial.

Authors:  Ana Molina; Ignacio Sanz-Sánchez; Conchita Martín; Juan Blanco; Mariano Sanz
Journal:  Clin Oral Implants Res       Date:  2016-03-25       Impact factor: 5.977

7.  Marginal bone and soft tissue behavior following platform switching abutment connection/disconnection--a dog model study.

Authors:  Célia C Alves; Fernando Muñoz; António Cantalapiedra; Isabel Ramos; Manuel Neves; Juan Blanco
Journal:  Clin Oral Implants Res       Date:  2014-04-16       Impact factor: 5.977

8.  Resonance frequency analysis-reliability in third generation instruments: Osstell mentor®.

Authors:  Mariano Herrero-Climent; Matteo Albertini; Jose-Vicente Rios-Santos; Pedro Lázaro-Calvo; Ana Fernández-Palacín; Pedro Bullon
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-09-01

9.  Conventional versus Digital Impressions for Full Arch Screw-Retained Maxillary Rehabilitations: A Randomized Clinical Trial.

Authors:  Paolo Cappare; Gianpaolo Sannino; Margherita Minoli; Pietro Montemezzi; Francesco Ferrini
Journal:  Int J Environ Res Public Health       Date:  2019-03-07       Impact factor: 3.390

View more
  2 in total

1.  The Association of the One-Abutment at One-Time Concept with Marginal Bone Loss around the SLA and Platform Switch and Conical Abutment Implants.

Authors:  Nasreen Hamudi; Eitan Barnea; Evgeny Weinberg; Amir Laviv; Eitan Mijiritsky; Shlomo Matalon; Liat Chaushu; Roni Kolerman
Journal:  J Clin Med       Date:  2021-12-24       Impact factor: 4.241

2.  Primary stability of different implant macrodesigns in a sinus floor elevation simulated model: an ex vivo study.

Authors:  Mikio Imai; Yoichiro Ogino; Hideaki Tanaka; Kiyoshi Koyano; Yasunori Ayukawa; Takeshi Toyoshima
Journal:  BMC Oral Health       Date:  2022-08-08       Impact factor: 3.747

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.