Ana Molina1, Ignacio Sanz-Sánchez1, Conchita Martín2, Juan Blanco3, Mariano Sanz1,4. 1. Section of Graduate Periodontology, University Complutense, Madrid, Spain. 2. Section of Graduate Orthodontics, University Complutense, Madrid, Spain. 3. Section of Graduate Periodontology, University of Santiago de Compostela, A Coruña, Spain. 4. ETEP (Etiology and Therapy of Periodontal Diseases) Research Group, University Complutense, Madrid, Spain.
Abstract
OBJECTIVE: To compare the effect of placing the definitive abutment at the time of implant placement versus at a later stage, on the soft and hard tissue changes around dental implants. MATERIAL AND METHODS: Platform-switched implants were placed in the posterior maxilla or mandible of partial edentulous patients and they were randomized to receive the definitive abutment at the moment of implant placement, or 6-12 weeks later. Final prostheses were delivered 2-4 weeks later. Radiographic assessment of vertical bone level changes (primary outcome), clinical status of peri-implant tissues, changes in soft tissues margin, papilla filling, patient-related outcomes and adverse events were assessed 6 and 12 months after loading. RESULTS:60 implants were placed in 40 patients, replacing single or multiple absent teeth. One implant was lost 1 week after insertion (overall survival rate: 98.3%). A statistically significant greater bone resorption from surgery to 6 months post-loading was observed for those implants subjected to abutment change (control group: -1.24 ± 0.79 mm; test group: -0.61 ± 0.40 mm; P = 0.028). Periodontal clinical parameters and patient-related outcomes, however, did not demonstrate significant differences between groups at any time point. A significant increase in papilla height was observed from loading to 12 months in all implants (control group: 1.17 ± 1.47 mm; test group: 0.98 ± 0.89 mm) and a slight but not significant coronal migration of the gingival margin. CONCLUSIONS: The connection and disconnection of healing abutments is associated with significantly increased bone loss during the healing period between implant placement and 6 months post-loading, when compared to one-time abutment placement.
RCT Entities:
OBJECTIVE: To compare the effect of placing the definitive abutment at the time of implant placement versus at a later stage, on the soft and hard tissue changes around dental implants. MATERIAL AND METHODS: Platform-switched implants were placed in the posterior maxilla or mandible of partial edentulouspatients and they were randomized to receive the definitive abutment at the moment of implant placement, or 6-12 weeks later. Final prostheses were delivered 2-4 weeks later. Radiographic assessment of vertical bone level changes (primary outcome), clinical status of peri-implant tissues, changes in soft tissues margin, papilla filling, patient-related outcomes and adverse events were assessed 6 and 12 months after loading. RESULTS: 60 implants were placed in 40 patients, replacing single or multiple absent teeth. One implant was lost 1 week after insertion (overall survival rate: 98.3%). A statistically significant greater bone resorption from surgery to 6 months post-loading was observed for those implants subjected to abutment change (control group: -1.24 ± 0.79 mm; test group: -0.61 ± 0.40 mm; P = 0.028). Periodontal clinical parameters and patient-related outcomes, however, did not demonstrate significant differences between groups at any time point. A significant increase in papilla height was observed from loading to 12 months in all implants (control group: 1.17 ± 1.47 mm; test group: 0.98 ± 0.89 mm) and a slight but not significant coronal migration of the gingival margin. CONCLUSIONS: The connection and disconnection of healing abutments is associated with significantly increased bone loss during the healing period between implant placement and 6 months post-loading, when compared to one-time abutment placement.
Authors: Matteo Albertini; Federico Herrero-Climent; Carmen María Díaz-Castro; Jose Nart; Ana Fernández-Palacín; José Vicente Ríos-Santos; Mariano Herrero-Climent Journal: Int J Environ Res Public Health Date: 2021-01-29 Impact factor: 3.390
Authors: José Vicente Ríos-Santos; Gregorio Tello-González; Pedro Lázaro-Calvo; Francisco Javier Gil Mur; Blanca Ríos-Carrasco; Ana Fernández-Palacín; Mariano Herrero-Climent Journal: Int J Environ Res Public Health Date: 2020-12-17 Impact factor: 3.390
Authors: Javier Montero; Javier Dolz; Francisco-Javier Silvestre; Javier Flores; Abraham Dib; Cristina Gómez-Polo Journal: Odontology Date: 2019-01-16 Impact factor: 2.634
Authors: Sven Marcus Beschnidt; Claudio Cacaci; Kerem Dedeoglu; Detlef Hildebrand; Helfried Hulla; Gerhard Iglhaut; Gerald Krennmair; Markus Schlee; Paul Sipos; Andres Stricker; Karl-Ludwig Ackermann Journal: Int J Implant Dent Date: 2018-11-02
Authors: Karl-Ludwig Ackermann; Thomas Barth; Claudio Cacaci; Steffen Kistler; Markus Schlee; Michael Stiller Journal: Int J Implant Dent Date: 2020-04-08