Literature DB >> 24735458

Marginal bone and soft tissue behavior following platform switching abutment connection/disconnection--a dog model study.

Célia C Alves1, Fernando Muñoz2, António Cantalapiedra2, Isabel Ramos1, Manuel Neves3, Juan Blanco1.   

Abstract

OBJECTIVE: The effect on the marginal peri-implant tissues following repeated platform switching abutment removal and subsequent reconnection was studied.
MATERIAL AND METHODS: Six adult female Beagle dogs were selected, and Pm3 and Pm4 teeth, both left and right sides, were extracted and the sites healed for 3 months. At this time, 24 bone level (BL) (Straumann, Basel, Switzerland) Ø 3.3/8 mm implants were placed, 2 in each side on Pm3 and Pm4 regions. In one side (control group), 12 bone level conical Ø 3.6 mm healing abutments and, on the other side (test group), 12 Narrow CrossFit (NC) multibase abutments (Straumann) , Basel, Switzerland) were connected at time of implant surgery. On test group, all prosthetic procedures were carried out direct to multibase abutment without disconnecting it, where in the control group, the multibase abutment was connected/disconnected five times (at 6/8/10/12/14 weeks) during prosthetic procedures. Twelve fixed metal bridges were delivered 14 weeks after implant placement. A cleaning/control appointment was scheduled 6 months after implant placement. The animals were sacrificed at 9 months of the study. Clinical parameters and peri-apical x-rays were registered in every visit. Histomorphometric analysis was carried out for the 24 implants. The distance from multibase abutment shoulder to the first bone implant contact (S-BIC) was defined as the primary histomorphometric parameter.
RESULTS: Wilcoxon comparison paired test (n = 6) found no statistically significant differences (buccal P = 0.917; Lingual P = 0.463) between test and control groups both lingually and buccally for S-BIC distance. Only Pm3 buccal aBE-BC (distance from the apical end of the barrier epithelium to the first bone implant contact) (P = 0.046) parameter presented statistically significant differences between test and control groups. Control group presented 0.57 mm more recession than test group, being this difference statistically significant between the two groups (P < 0.001).
CONCLUSION: It can be conclude, within the limits of this animal study, that the connection/disconnection of platform switching abutments during prosthetic phase of implant treatment does not induce bone marginal absorption. Furthermore, it may present a negative influence in the buccal connective tissue attachment that becomes shorter anyway preventing marginal hard tissue resorption, especially in thin biotypes.
© 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  abutment connection/disconnection; abutment manipulation; biologic width; marginal bone resorption; marginal soft tissue behavior; platform switching abutment

Mesh:

Substances:

Year:  2014        PMID: 24735458     DOI: 10.1111/clr.12385

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  9 in total

1.  Immediate definitive individualized abutments reduce peri-implant bone loss: a randomized controlled split-mouth study on 16 patients.

Authors:  M Erhan Çömlekoğlu; Nejat Nizam; Mine Dündar Çömlekoğlu
Journal:  Clin Oral Investig       Date:  2017-05-31       Impact factor: 3.573

2.  A Radiographic and Clinical Comparison of Immediate vs. Early Loading (4 Weeks) of Implants with a New Thermo-Chemically Treated Surface: A Randomized Clinical Trial.

Authors:  Matteo Albertini; Federico Herrero-Climent; Carmen María Díaz-Castro; Jose Nart; Ana Fernández-Palacín; José Vicente Ríos-Santos; Mariano Herrero-Climent
Journal:  Int J Environ Res Public Health       Date:  2021-01-29       Impact factor: 3.390

Review 3.  One-time versus repeated abutment connection for platform-switched implant: A systematic review and meta-analysis.

Authors:  Qing-Qing Wang; Ruoxi Dai; Chris Ying Cao; Hui Fang; Min Han; Quan-Li Li
Journal:  PLoS One       Date:  2017-10-19       Impact factor: 3.240

4.  Esthetic outcome of immediately placed and nonfunctionally loaded implants in the anterior maxilla utilizing a definitive abutment: A pilot clinical trial.

Authors:  Sandra AlTarawneh; Ahmad A S Hamdan; Abeer Alhadidi; Susan Hattar; Mohammad Al-Rabab'ah; Zaid Baqain
Journal:  Dent Res J (Isfahan)       Date:  2020-03-17

5.  One Abutment One Time: A Multicenter, Prospective, Controlled, Randomized Study.

Authors:  José Vicente Ríos-Santos; Gregorio Tello-González; Pedro Lázaro-Calvo; Francisco Javier Gil Mur; Blanca Ríos-Carrasco; Ana Fernández-Palacín; Mariano Herrero-Climent
Journal:  Int J Environ Res Public Health       Date:  2020-12-17       Impact factor: 3.390

6.  Peri-implant tissue alteration around tissue-level and bone-level implants in fresh extraction sockets: a histomorphometric study in dogs.

Authors:  Chunan Zhang; Xu Zhao; Shichong Qiao; Xiaomeng Zhang; Hongchang Lai; Yingxin Gu
Journal:  Ann Transl Med       Date:  2021-02

7.  Comparative evaluation of peri-implant tissues in definitive and repeated abutment replacements: A randomized clinical trial.

Authors:  Prachi Rajendra Rathi; Rajashri Abhay Kolte; Abhay Pandurang Kolte
Journal:  J Indian Soc Periodontol       Date:  2022-01-01

8.  The Association of the One-Abutment at One-Time Concept with Marginal Bone Loss around the SLA and Platform Switch and Conical Abutment Implants.

Authors:  Nasreen Hamudi; Eitan Barnea; Evgeny Weinberg; Amir Laviv; Eitan Mijiritsky; Shlomo Matalon; Liat Chaushu; Roni Kolerman
Journal:  J Clin Med       Date:  2021-12-24       Impact factor: 4.241

9.  Digital vs. conventional workflow for one-abutment one-time immediate restoration in the esthetic zone: a randomized controlled trial.

Authors:  Brieuc Hanozin; Lou Li Manni; Geoffrey Lecloux; Miljana Bacevic; France Lambert
Journal:  Int J Implant Dent       Date:  2022-02-07
  9 in total