Literature DB >> 3328620

Design principles and clinical possibilities with a new generation of radiation therapy equipment. A review.

A Brahme1.   

Abstract

The main steps in the development of isocentric megavoltage external beam radiation therapy machines are briefly reviewed identifying three principal types or generations of equipment to date. The new fourth generation of equipment presented here is characterized by considerably increased flexibility in dose delivery through the use of scanned elementary electron and photon beams of very high quality. Furthermore the wide energy range and the possibility of using high resolution multileaf collimation with all beam modalities makes it possible to simplify irradiation techniques and increase the accuracy in dose delivery. The main design features are described including a dual dipole magnet scanning system, a photon beam purging magnet, a helium atmosphere in the treatment head, a beam's eye view video read-out system of the collimator setting and a radiotherapeutic computed tomography facility. Some of the clinical applications of this new type of radiation therapy machine are finally reviewed, such as the ease of performing beam flattening, beam filtering and compensation, and the simplification of many treatment techniques using the wide spectrum of high quality electron and photon beams. Finally the interesting possibility of doing conformation and more general isocentric treatments with non-uniform beams using the multileaf collimator and the scanning system are demonstrated.

Entities:  

Mesh:

Year:  1987        PMID: 3328620     DOI: 10.3109/02841868709113708

Source DB:  PubMed          Journal:  Acta Oncol        ISSN: 0284-186X            Impact factor:   4.089


  8 in total

1.  QA issues for computer-controlled treatment delivery: this is not your old R/V system any more!

Authors:  Benedick A Fraass
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008       Impact factor: 7.038

Review 2.  Radiotherapy for head and neck tumours in 2012 and beyond: conformal, tailored, and adaptive?

Authors:  Vincent Grégoire; Robert Jeraj; John Aldo Lee; Brian O'Sullivan
Journal:  Lancet Oncol       Date:  2012-06-28       Impact factor: 41.316

3.  Comparison of three different phantoms used for Winston-Lutz test with Artiscan software.

Authors:  Hubert Szweda; Kinga Graczyk; Dawid Radomiak; Krzysztof Matuszewski; Bartosz Pawałowski
Journal:  Rep Pract Oncol Radiother       Date:  2020-03-04

4.  Conformal therapy.

Authors:  D Tait
Journal:  Br J Cancer       Date:  1990-11       Impact factor: 7.640

5.  Dosimetric characteristics of an electron multileaf collimator for modulated electron radiation therapy.

Authors:  Ahmed Abdel Rahman Eldib; Mohamed I ElGohary; Jiajin Fan; Lihui Jin; Jinsheng Li; Charlie Ma; Nader A Elsherbini
Journal:  J Appl Clin Med Phys       Date:  2010-04-12       Impact factor: 2.102

6.  Analytical investigation of magnetic field effects on Proton lateral deflection and penetrating depth in the water phantom: A relativistic approach.

Authors:  Mohammad Javad Tahmasebi Birgani; Nahid Chegeni; Mansour Zabihzadeh; Marziyeh Tahmasbi
Journal:  Electron Physician       Date:  2017-12-25

7.  Point Dose Measurement for Verification of Treatment Planning System using an Indigenous Heterogeneous Pelvis Phantom for Clarkson, Convolution, Superposition, and Fast Superposition Algorithms.

Authors:  S Singh; P Raina; O P Gurjar
Journal:  J Biomed Phys Eng       Date:  2019-12-01

8.  A prospective in silico analysis of interdisciplinary and interobserver spatial variability in post-operative target delineation of high-risk oral cavity cancers: Does physician specialty matter?

Authors:  Sweet Ping Ng; Brandon A Dyer; Jayashree Kalpathy-Cramer; Abdallah Sherif Radwan Mohamed; Musaddiq J Awan; G Brandon Gunn; Jack Phan; Mark Zafereo; J Matthew Debnam; Carol M Lewis; Rivka R Colen; Michael E Kupferman; Nandita Guha-Thakurta; Guadalupe Canahuate; G Elisabeta Marai; David Vock; Bronwyn Hamilton; John Holland; Carlos E Cardenas; Stephen Lai; David Rosenthal; Clifton David Fuller
Journal:  Clin Transl Radiat Oncol       Date:  2018-08-02
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.