Literature DB >> 33257960

Safety and efficacy of transvenous lead extraction of very old leads.

Simon Pecha1, Tibor Ziegelhoeffer2, Yalin Yildirim1, Yeong-Hoon Choi2,3,4, Stephan Willems5, Hermann Reichenspurner1, Heiko Burger2, Samer Hakmi5.   

Abstract

OBJECTIVES: Transvenous lead extraction using mechanical rotational- or laser sheaths is an established procedure. Lead dwell time has been recognized as a risk factor for extraction failure and procedure-related complications. We therefore investigated the safety and efficacy of transvenous extraction of leads with an implant duration of more than 10 years.
METHODS: Between January 2013 and March 2017, a total of 403 patients underwent lead extraction in 2 high-volume lead extraction centres. One hundred and fifty-four patients with extraction of at least 1 lead aged over 10 years were included in this analysis. Laser lead extraction was the primary extraction method, with additional use of mechanical rotational sheaths or femoral snares, if necessary. All procedural- and patient-based data were collected into a database and retrospectively analysed.
RESULTS: Mean patient's age was 65.8 ± 15.8 years, 68.2% were male. Three hundred and sixty-two leads had to be extracted. The mean lead dwell time of treated leads was 14.0 ± 6.1 years. Complete procedural success was achieved in 91.6% of cases, while clinical success was achieved in 96.8%. Failure of extraction occurred in 3.2%. Leads that could not be completely removed had a significantly longer lead dwell time (18.2 vs 13.2 years; P = 0.016). Additional mechanical rotational sheaths or femoral snares were used in 26 (16.9%) patients. Overall complication rate was 4.6%, including 5 (3.3%) major and 2 (1.3%) minor complications. There was no procedure-related mortality.
CONCLUSIONS: Transvenous lead extraction in leads aged over 10 years is safe and effective when performed in specialized centres and with use of multiple tools and techniques. Leads that could not be completely extracted had a statistically significant longer lead dwell time.
© The Author(s) 2020. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  Implantable cardioverter defibrillator lead extraction; Laser lead extraction; Lead extraction; Mechanical lead extraction; Pacemaker lead extraction

Mesh:

Year:  2021        PMID: 33257960      PMCID: PMC8906697          DOI: 10.1093/icvts/ivaa278

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  27 in total

1.  Trends, indications and outcomes of cardiac implantable device system extraction: a single UK centre experience over the last decade.

Authors:  A Arujuna; S Williams; J Whittaker; A Shetty; D Roy; J Bostock; S Kirubakaran; M O'Neill; J Gill; M Cooklin; N Patel; C Blauth; C Bucknall; S Hamid; C A Rinaldi
Journal:  Int J Clin Pract       Date:  2012-02       Impact factor: 2.503

2.  Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA).

Authors:  Bruce L Wilkoff; Charles J Love; Charles L Byrd; Maria Grazia Bongiorni; Roger G Carrillo; George H Crossley; Laurence M Epstein; Richard A Friedman; Charles E H Kennergren; Przemyslaw Mitkowski; Raymond H M Schaerf; Oussama M Wazni
Journal:  Heart Rhythm       Date:  2009-05-22       Impact factor: 6.343

3.  Transvenous extraction of very old (over 20-year-old) pacemaker leads using mechanical systems: Effectiveness and safety.

Authors:  Andrzej Ząbek; Krzysztof Boczar; Maciej Dębski; Paweł T Matusik; Roman Pfitzner; Mateusz Ulman; Robert Musiał; Jacek Lelakowski; Barbara Małecka
Journal:  Pacing Clin Electrophysiol       Date:  2019-05-14       Impact factor: 1.976

Review 4.  2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction.

Authors:  Fred M Kusumoto; Mark H Schoenfeld; Bruce L Wilkoff; Charles I Berul; Ulrika M Birgersdotter-Green; Roger Carrillo; Yong-Mei Cha; Jude Clancy; Jean-Claude Deharo; Kenneth A Ellenbogen; Derek Exner; Ayman A Hussein; Charles Kennergren; Andrew Krahn; Richard Lee; Charles J Love; Ruth A Madden; Hector Alfredo Mazzetti; JoEllyn Carol Moore; Jeffrey Parsonnet; Kristen K Patton; Marc A Rozner; Kimberly A Selzman; Morio Shoda; Komandoor Srivathsan; Neil F Strathmore; Charles D Swerdlow; Christine Tompkins; Oussama Wazni
Journal:  Heart Rhythm       Date:  2017-09-15       Impact factor: 6.343

5.  Lead extraction with high frequency laser sheaths: a single-centre experience.

Authors:  Simon Pecha; Matthias Linder; Nils Gosau; Liesa Castro; Julia Vogler; Stephan Willems; Hermann Reichenspurner; Samer Hakmi
Journal:  Eur J Cardiothorac Surg       Date:  2017-05-01       Impact factor: 4.191

6.  Trends in permanent pacemaker implantation in the United States from 1993 to 2009: increasing complexity of patients and procedures.

Authors:  Arnold J Greenspon; Jasmine D Patel; Edmund Lau; Jorge A Ochoa; Daniel R Frisch; Reginald T Ho; Behzad B Pavri; Steven M Kurtz
Journal:  J Am Coll Cardiol       Date:  2012-09-19       Impact factor: 24.094

7.  Evolution in transvenous extraction of pacemaker and implantable cardioverter defibrillator leads using a mechanical dilator sheath.

Authors:  Ali Oto; Kudret Aytemir; Uğur Canpolat; Hikmet Yorgun; Levent Şahiner; Ergün Bariş Kaya; Giray Kabakçi; Lale Tokgözoğlu
Journal:  Pacing Clin Electrophysiol       Date:  2012-04-05       Impact factor: 1.976

8.  Implantation trends and patient profiles for pacemakers and implantable cardioverter defibrillators in the United States: 1993-2006.

Authors:  Steven M Kurtz; Jorge A Ochoa; Edmund Lau; Yakov Shkolnikov; Behzad B Pavri; Daniel Frisch; Arnold J Greenspon
Journal:  Pacing Clin Electrophysiol       Date:  2010-01-04       Impact factor: 1.976

9.  Update on cardiovascular implantable electronic device infections and their management: a scientific statement from the American Heart Association.

Authors:  Larry M Baddour; Andrew E Epstein; Christopher C Erickson; Bradley P Knight; Matthew E Levison; Peter B Lockhart; Frederick A Masoudi; Eric J Okum; Walter R Wilson; Lee B Beerman; Ann F Bolger; N A Mark Estes; Michael Gewitz; Jane W Newburger; Eleanor B Schron; Kathryn A Taubert
Journal:  Circulation       Date:  2010-01-04       Impact factor: 29.690

10.  Success and complication rates of lead extraction with the first- vs. the second-generation Evolution mechanical sheath.

Authors:  Olivier A Witte; Ahmet Adiyaman; Jaap Jan J Smit; Anand R Ramdat Misier; Arif Elvan; Abdul Ghani; Peter Paul H M Delnoy
Journal:  Europace       Date:  2017-10-01       Impact factor: 5.214

View more
  1 in total

1.  Analysis of Risk Factors for Major Complications of 1500 Transvenous Lead Extraction Procedures with Especial Attention to Tricuspid Valve Damage.

Authors:  Łukasz Tułecki; Anna Polewczyk; Wojciech Jacheć; Dorota Nowosielecka; Konrad Tomków; Paweł Stefańczyk; Jarosław Kosior; Krzysztof Duda; Maciej Polewczyk; Andrzej Kutarski
Journal:  Int J Environ Res Public Health       Date:  2021-08-28       Impact factor: 3.390

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.