BACKGROUND: Unicondylar knee arthroplasty was introduced in the late 1960s and remains a topic of controversial discussion. Patient-specific instruments and patient-specific implants are not yet the standard of care. The question remains whether this time-consuming and costly technique can be beneficial for the patient. The aim of this study was to evaluate whether a custom-made unicondylar knee arthroplasty leads to improved patient-reported outcome. METHODS: This retrospective study evaluates the patient-reported outcome after custom-made unicondylar knee arthroplasty (CM-UKA, ConforMIS™ iUni® G2, ConforMIS Inc., Billerica, MA, USA). We evaluated 29 patients (31 knees) at an average of 2.4 years (range 1.2-3.6 years) after operation for unicondylar osteoarthritis of the knee. The target zone for the postoperative leg axis was a slight under-correction of 0-2° varus. Follow-up evaluation included the Forgotten Joint Score (FJS), the Knee Society Score (KSS), a Visual Analogue Scale (VAS) and a radiographic evaluation including a long-leg radiograph. Primary outcome measure was patient satisfaction based on the Forgotten Joint Score. RESULTS: We found an excellent postoperative health-related quality of life with a mean FJS of 76.8 (SD 17.9) indicating a low level of joint awareness after CM-UKA. The mean preoperative KSS was 66.0 (SD 13.71) and 59.4 (17.9) for the KSS function score. The increase was 22.8 points for the KSS knee score (p < 0.0001) and 34.8 points for the KSS function score (p < 0.0001). The VAS for pain decreased from a mean of 5.4 (SD 1.8) to 1.1 (SD 1.2) (p < 0.0001). The malalignment rate with a postoperative deviation of more than 2° in the leg axis was 29%. There was no evidence of component loosening after a mean follow-up of 2.4 years. CONCLUSIONS: Custom-made unicondylar knee arthroplasty (CM-UKA) can provide improved clinical and functional outcomes for patients with isolated knee osteoarthritis of the medial compartment. We found excellent results regarding patient satisfaction and a low malalignment rate for CM-UKA. Further studies are needed to investigate long-term survivorship of the implant. LEVEL OF EVIDENCE: Level IV. TRIAL REGISTRATION: Trial Registration number: Z-2014-0389-10 Regensburg Clinical Studies Center (REGCSC) 09/07/2014.
BACKGROUND: Unicondylar knee arthroplasty was introduced in the late 1960s and remains a topic of controversial discussion. Patient-specific instruments and patient-specific implants are not yet the standard of care. The question remains whether this time-consuming and costly technique can be beneficial for the patient. The aim of this study was to evaluate whether a custom-made unicondylar knee arthroplasty leads to improved patient-reported outcome. METHODS: This retrospective study evaluates the patient-reported outcome after custom-made unicondylar knee arthroplasty (CM-UKA, ConforMIS™ iUni® G2, ConforMIS Inc., Billerica, MA, USA). We evaluated 29 patients (31 knees) at an average of 2.4 years (range 1.2-3.6 years) after operation for unicondylar osteoarthritis of the knee. The target zone for the postoperative leg axis was a slight under-correction of 0-2° varus. Follow-up evaluation included the Forgotten Joint Score (FJS), the Knee Society Score (KSS), a Visual Analogue Scale (VAS) and a radiographic evaluation including a long-leg radiograph. Primary outcome measure was patient satisfaction based on the Forgotten Joint Score. RESULTS: We found an excellent postoperative health-related quality of life with a mean FJS of 76.8 (SD 17.9) indicating a low level of joint awareness after CM-UKA. The mean preoperative KSS was 66.0 (SD 13.71) and 59.4 (17.9) for the KSS function score. The increase was 22.8 points for the KSS knee score (p < 0.0001) and 34.8 points for the KSS function score (p < 0.0001). The VAS for pain decreased from a mean of 5.4 (SD 1.8) to 1.1 (SD 1.2) (p < 0.0001). The malalignment rate with a postoperative deviation of more than 2° in the leg axis was 29%. There was no evidence of component loosening after a mean follow-up of 2.4 years. CONCLUSIONS: Custom-made unicondylar knee arthroplasty (CM-UKA) can provide improved clinical and functional outcomes for patients with isolated knee osteoarthritis of the medial compartment. We found excellent results regarding patient satisfaction and a low malalignment rate for CM-UKA. Further studies are needed to investigate long-term survivorship of the implant. LEVEL OF EVIDENCE: Level IV. TRIAL REGISTRATION: Trial Registration number: Z-2014-0389-10 Regensburg Clinical Studies Center (REGCSC) 09/07/2014.
Although unicondylar knee arthroplasty (UKA) was already introduced in the late 1960s by Marmor et al. [1] it is still a topic of controversial discussion. Compared to total knee arthroplasty (TKA), implantation of UKA is less invasive due to a smaller skin incision, less blood loss and greater preservation of the patient’s anatomy [2-4]. Large, registry-based studies have shown better postoperative knee function and increased patient satisfaction but also increased revision rates in comparison to TKA [5, 6]. Recent studies on comparison of UKA and TKA proved a superior proprioceptive capacity and improved health-related quality of life (HR-QoL) for UKA [7]. A better understanding of the causes of failure has led to improved clinical results and higher patient satisfaction over the last decade [8]. In addition, prior studies have shown that surgeons who regularly perform implantation of UKA have a lower complication rate, especially lower mechanical complications [9, 10]. Introduction of patient-specific surgical instruments and implants are seen to have tremendous potential to improve the standard of care [11, 12]. In most studies, the term patient-specific UKA is associated with the use of patient-specific instruments for the implantation of a standard prosthesis. In this study, we used patient-specific instruments to implant a custom-made prosthesis based on a preoperative CT scan of the knee (ConforMIS™ iUni® G2, ConforMIS Inc., Billerica, MA, USA). Therefore, we use the term custom-made unicondylar knee arthroplasty (CM-UKA) to indicate that instruments and implants were patient-specific. Previous studies on patient-specific instrumentation of UKA have demonstrated superior implant fit compared to standard UKA [13]. The question remains whether this type of implant can be beneficial for the patient’s perception of the joint after arthroplasty. Conventional outcome measurement tools focus on functional aspects like the range of motion or ligamentous stability [14, 15]. In recent studies, more importance has been placed on patient-reported outcome. There is currently a lack of research into the impact of a patient-specific implant on patient-reported outcome (PRO). The purpose of this study is to investigate short-term PRO in patients with CM-UKA for unicompartmental osteoarthritis of the knee.
Methods
Study design
This retrospective, monocentric case study includes 31 knees in 29 consecutive patients who were treated with CM-UKA for medial unicompartmental osteoarthritis of the knee between January 2010 and December 2012. Our institution is a highly specialized unit with prospective data collection for all arthroplasty patients. We collected perioperative data of the study population from the hospital’s database retrospectively and performed clinical radiological re-evaluation at follow-up. The indication for CM-UKA was based on modified criteria by Kozinn and Scott [16]. The implants used were the second generation of the custom-made unicondylar arthroplasty implant (ConforMIS™ iUni® G2, ConforMIS Inc., Billerica, MA, USA). Preoperative planning and manufacturing process of the CM-UKA requires around 6 weeks. Based on a 3D reconstruction of a CT scan of the knee, the size and position of the patient-specific implant are determined (Fig. 1). To determine the leg axis, additional short distance scans of the hip and ankle joint have to be included in the CT scan. The planning software indicates osteophytes that have to be removed for correct positioning of the cutting guide instruments on femur and tibia. After removal of the osteophytes, the jig fits perfectly on the condyle. Placement of the saw guides is crucial to ensure correct transformation from the preoperative planning to definitive implant position. This type of implant has a fixed-bearing inlay and requires cementing of both components (femoral and tibial).
Fig. 1
Preoperative planning procedure to determine optimal implant size and position
Preoperative planning procedure to determine optimal implant size and positionInclusion criteria for this study were:isolated femoro-tibial OA of the medial compartment (grade II-IV according to Kellgren and Lawrence)sufficient bone stock in the medial compartment for anchoring of the implantintact cruciate ligaments and collateral ligamentsExclusion criteria were:varus deformity greater than 15°osteonecrosis of the distal femur or proximal tibiapost-traumatic or post-infectious OAlost to follow-upTwo patients were lost to follow-up, leaving 29 patients (31 UKAs) as study population. With a mean follow-up of 2.4 years (range 1.2–3.6 years), the remaining 31 CM-UKAs were evaluated clinically and radiographically by the first author. Primary outcome measure was the FJS at follow-up.
Clinical evaluation
The average age of the sample was 67 years (range: 52–80 years) (Table 1). Twenty-three patients had prior surgery on the knee in their medical history (22 arthroscopies, 3 tibial osteotomies). All patients underwent conservative non-operative treatment prior to the arthroplasty (analgesia, anti-inflammatory drugs, injections, physical therapy, or acupuncture). Regarding the mechanical axis, the target zone was a slight under-correction of 0–2° varus [17, 18].
Table 1
Table showing patient demographics from our study
Age
67 years (52–80 years)
Sex
14 females (55%)
17 males (45%)
Compartment
31 medial (100%)
ASAa
7 patients with ASA II (23%)
24 patients with ASA III (77%)
BMIa
31.2 kg/m2 (24.6–45.4 kg/m2)
Follow-up
2.4 years (14 to 44 months)
aASA American Society of Anesthesiologists, BMI Body Mass Index
Table showing patient demographics from our study14 females (55%)17 males (45%)7 patients with ASA II (23%)24 patients with ASA III (77%)aASA American Society of Anesthesiologists, BMI Body Mass IndexThe evaluation at follow-up was conducted by the first author and included medical history, a standardized clinical examination, and assessment of the following clinical scores:clinical examination including range of motion (ROM) and ligamentous stabilityForgotten Joint Score (FJS) [19]Knee Society Score (KSS) [15, 20]Tegner Activity Level Scale [14]Visual Analogue Scale (VAS) for acute pain [21]Visual Analogue Scale (VAS) for patient satisfaction
Forgotten joint score (FJS)
The FJS score is a self-administrated 12-item PRO tool measuring the loss of awareness of an artificial joint as an indicator for the postoperative outcome.The score is reported on a scale from 0 to 100, where 100 represents the best outcome indicating that the patient is not aware of the artificial joint in everyday life. Validation studies proved excellent psychometric properties and revealed a minimum important clinical difference (MICD) of 14 points [19, 22–26].The patients were asked to rate their level of satisfaction on a visual analog scale. The value was transformed into the following categories: 8–10 = “very satisfied”, 6–8 = “satisfied”, 4–6 = “neither satisfied nor dissatisfied”, 2–4 = “dissatisfied”, 0–2 = “very dissatisfied”.
Radiological assessment
The radiographic analysis consisted of a weight-bearing long-leg view, an anterior-posterior view, a lateral view of the knee, and a patella axial view. The degree of OA was rated according to the Kellgren and Lawrence Score (KLS) [27] for pre- and postoperative images. The evaluation was made for each compartment separately. The retro-patellar OA was classified according to Sperner [28]. The radiological analysis was carried out using the zone method according to Gulati et al. [29] (Fig. 2. & Table 2). The thickness and location of radiolucent lines (RLL) was registered.
Fig. 2
Radiographs with design of the specified regions for evaluation of presence and extent of radiolucency under the components
Table 2
Extend of radiolucent lines under the components
Tibial interface (A)
Femoral interface (B)
none
N = 25; 80.6%
N = 30; 96.8%
1-2 mm
N = 4; 12.9%
N = 1; 3.2%
> 2 mm
N = 1; 3.2%
–
Radiographs with design of the specified regions for evaluation of presence and extent of radiolucency under the componentsExtend of radiolucent lines under the components
Statistical analysis
Statistical analysis was performed using the software package SPSS (Version 23, SPSS Inc., Chicago, Illinois). With the limited number of cases presented in this study, assumption of normal distribution is critical. As a consequence, outcome data should be expressed as median. However, for comparison reasons, we present mean values ± standard deviation. The level of significance was at p < 0.05 for all tests.Due to the fact that there is no previous data on joint awareness in CM-UKA, this preliminary study was designed as an exploratory pilot study without any a priori sample size calculation based on a primary endpoint. Since normal distribution could not be assumed for all variables (according to the Shapiro-Wilk normality test), a two-tailed Wilcoxon Signed Ranks Test was used to examine related samples; e.g. comparing pre- and post-operative results of the KSS, the VAS for pain, and the TAS. The Mann-Whitney U-Test was used to compare non-related samples.The Ethics Committee at the University of Regensburg approved the study in May 2014 (Institutional Review Board Number 14–101-0135). The study was registered at the Center for Clinical Studies at the University Clinic of Regensburg at the 09/07/2014. Trial Registration number: Z-2014-0389-10- Regensburg Clinical Studies Center (REGCSC).A written informed consent was obtained from all patients in accordance with the declaration of Helsinki.
Results
Table 1 shows demographic data recorded in 31 knees. The average BMI was 31.2 (range, 24.6–45.4) and obesity was not a determining factor in whether or not to choose a UKA. The average pre-operative range of motion was 115° (range: 90–130). The mean preoperative KSS Knee score was 66.0 (SD 13.71) and 59.4 (17.9) for the KSS function score. The increase was 22.8 points for the KSS knee score (p < 0.0001) and 34.8 points for the KSS function score (p < 0.0001). No general complication had occurred by the time of follow-up (e.g. thromboembolism, hemorrhage, prolonged wound healing, or post-operative infection). At follow-up, 90.3% of patients reported either no pain or only occasional light pain. One patient was cane-dependent due to a gait disturbance as a consequence of a prior stroke. All other patients reported the ability to walk an unlimited distance. The mean FJS was 76.8 (SD 17.9) indicating a low level of joint awareness of the CM-UKA. The mean Tegner Activity Level improved from 2.6 (SD 0.9) preoperatively to 3.3 (SD 1.0) postoperatively (p < 0.0001). The VAS for pain during activity of daily living decreased from a mean of 5.4 (SD 1.8) to 1.1 (SD 1.2) (p < 0.0001). There was a significant improvement in all clinical scores that were measured at pre- and post-operatively (Table 3). 27 of the 31 patients were very satisfied (VAS 8–10), 2 satisfied (VAS 6–8), and 2 were not satisfied but not dissatisfied (VAS 4–6).
Table 3
Summary of outcome for the cohort. Clinical scores with means presented with standard deviation (SD) in the two groups; pre- and post-operatively with p-value
Pre-operative: Mean (SD)
Post-operative: Mean (SD)
P-value
FJS
–
76.8 (17.9)
–
KSS Knee
66.0 (13.7)
88.8 (6.6)
< 0.001 *
KSS Function
59.4 (17.9)
94.2 (11.0)
< 0.001 *
Tegner
2.6 (0.9)
3.3 (1.0)
0.003 *
VAS-pain
5.4 (1.8)
1.1 (1.2)
< 0.001*
Sperner Score
Patellofemoral joint
1.1 (0.6)
1.8 (0.8)
0.001 *
Kellgren Score
Lateral compartment
0.3 (0.5)
1.45 (0.7)
< 0.001*
Femorotibial alignment
176° (2.3) -4° varus
179.4°(2.5) -0,6° varus
< 0.001 *
*level of significance α = 0.05 (Wilcoxon-Signed Rank Test)
Summary of outcome for the cohort. Clinical scores with means presented with standard deviation (SD) in the two groups; pre- and post-operatively with p-valueSperner ScorePatellofemoral jointKellgren ScoreLateral compartment*level of significance α = 0.05 (Wilcoxon-Signed Rank Test)The short-term survival of the implant, considering revision and radiologic loosening to be failures, was 100%. There was no evidence of component loosening in any patient. Five patients showed partial RLL, of which one patient presented partial radiolucency in the femoral component in the very anterior region (zone 10) of less than 2 mm. Five patients showed partial lucency under the tibial component, only one of them > 2 mm. The very lateral zone (zone 1) was affected in 2 cases.We recorded an increase of the mean KLS in the lateral compartment of 0.3 (SD 0.5) preoperatively to 1.5 (SD 0.7) at follow-up (p < 0.001). However, none of these patients complained of pain, joint effusion or other clinical symptoms from the lateral compartment degeneration. No patient with a BMI < 25 kg/m2 showed progression of OA in the lateral compartment.The retro-patellar OA according to Sperner increased from a mean of 1,1 (SD 0,6) to 1.77 (SD 0.76) (p = 0.001). No patient with a BMI < 25 kg/m2 showed any sign of radiographic progression of the retro-patellar OA. No patient had any account of clinical symptoms or pain and the patellar femoral grind test [30] was negative in all patients.We recorded a correction of the mechanical axis in long-leg views from 4° of varus (SD 2.3) preoperatively to a mean varus of 0.6° (SD 2.5). We aimed for a slight under-correction of the mechanical axis of 0–2° varus. In 22/31 knees the aimed range of 0–2° of varus was achieved. The malalignment rate in total was 29% (4 knees were under-corrected with up to 5° of varus, 5 knees were over-corrected to a valgus alignment of less than 5°) (Fig. 3). There was no relationship between malalignment (2–5° varus or valgus) and reduced outcome of the FJS.
Fig. 3
Postoperative mechanical leg axis alignment
Postoperative mechanical leg axis alignment
Discussion
Main finding of this study is that CM-UKA for unicondylar OA of the knee can provide improved clinical and functional outcome. This is the first study to report on PRO of custom-made implants of a UKA. We found good results regarding patient satisfaction indicated by a low level of postoperative joint awareness measured by the FJS. These findings are also reflected in good short-term clinical and radiological results at an average follow-up of 2.4 years.UKA is a well-established procedure for treatment of unicondylar OA of the knee. However, the clinical and radiological results are heterogeneous. There is an ongoing discussion about criteria for patient selection and improvement of surgical technique to optimize postoperative outcome [31-33]. With a mean age of 67 years, our patient population had the typical age distribution in patients requiring UKA for unicondylar compartment OA. The BMI had no significant effect on postoperative outcome, consistent with findungs in previous studies by Murray et al. [34] and Thompson et al. [35]Prior studies have shown that surgeon-related factors like the implantation technique are of great importance since inadequate positioning of the implant is the main cause for early failure [36]. Generally, implantation of UKA is technically more challenging than TKA, especially with regards to implant alignment and placement [37]. Overcorrection of the leg axis can lead to progression of OA with persistent pain in the contralateral compartment, and should therefore be avoided [18]. Severe under-correction (HKA angle < 170°) is equally undesirable due to wear of the inlay [38]. Hernigou et al. even suggested that a varus alignment with a HKA angle of up to 171° leads to lower wear [36]. Koeck et al. described the target of leg axis correction with this specific implant as a slight under-correction of 0–2° of varus [17, 18]. In our patient population, we were able to achieve this target in 22 of the 31 cases. Mullaji et al. report that a preoperatively strongly deviating leg axis was more likely to present a postoperative remaining varus, whereas a leg axis with only a slight varus was more likely to achieve the wanted 0–2° of varus [39]. Gulati et al. state that malalignment does not allow conclusions about the level of patient satisfaction [40]. Our results on the FJS support this assumption. However, this refers to patients with a moderate postoperative deviation of axis less than 5° [41].Mechanical malalignment of the implant is seen as a risk factor for early loosening. Batailler et al. recently published a study on robotic-assisted UKA compared to a conventional free-hand implantation of UKA. They found a decreased misalignment rate of a postoperative leg axis deviation of more than 2° in 16% of robotic-assisted UKA, compared to 32% in the control group treated with conventional free-hand implantation. We found a malalignment rate of 29% and no case of a varus or valgus deviation greater than 5° in our population. Batailler et al. recorded patients with a malalignment of more than 10°, even in the robotic-assisted group. In their study, malalignment was the reason for revision in three patients of the control group and they observed three revisions for aseptic loosening after a mean follow-up of 19.7 months. We did not record any revision due to malalignment or aseptic loosening in our population. However, long-term studies are required to analyze survivorship of this type of implant.Several studies have proven superior functional abilities and patient satisfaction for a UKA compared to TKA [2, 41–46]. It should be noted that there is still a significant number of dissatisfied patients even among those with an excellent outcome based on objectifiable clinical and radiological criteria [38, 47]. The influence of PRO in clinical decision making is rising. Several authors have investigated PRO during the first 2 years after knee arthroplasty and found no relevant change later than 12 months postoperatively [26, 48, 49]. Accordingly, we chose a minimum-follow-up of 1 year postoperatively for evaluation in this study.In comparison to studies with a similar collective and observational period for unicompartmental prosthesis, our results are similar regarding satisfaction, KSS for pain and function, pain reduction and FJS [42, 44]. The postoperative increase of the KSS after CM-UKA exceeded MICD of 7.2 points by far [50]. Reduction of pain, measured by the VAS for pain, was also at a clinically relevant level of 1.6 [51]. The change in the nominal Tegner Activity Scale increased by 0.7 levels. The ultimate goal in UKA should be the complete unawareness oblivion of the knee in patients’ everyday life. But even results of a healthy group of controls reported by Behrend et al. have shown a FJS of 86.6 (SD 17) for male and 79.3 (SD 23.2) for female participants, therefore showing that even healthy subjects become aware of their knee joints in everyday life [19].Flury et al. examined the outcome of patient specific UKA 55 months after implantation. FJS was 87 (SD 23) and 89.6% of all patients reported satisfaction during the final follow up. They found an implant survival rate of 92% and excellent accuracy regarding component placement in UKA [52]. Even though well-established standard implants result in a lower FJS than patient specific implants, UKA in general shows superior results than TKA.A study by Zuiderbaan evaluated FJS in standard UKA and found a FJS of 74.3 ± 24.8, compared to a FJS of 59.8 ± 31.5 in TKA 2 years after implantation [53].Baumann et al. compared the FJS of patients with bicruciate-retaining implants (53.4 ± 26.4), cruciate-sacrificing implants (38.9 ± 22.0) and standard UKA (53.6 ± 22.2) 18 months postoperatively [7]. Stempin et al. conducted a study to evaluate the medium-term outcome of cementless, mobile-bearing, unicompartmental knee arthroplasty and found a FJS of 75.5 (SD 5.5) after 5 years [54]. Peersmann et al. evaluated patients in a prospective cohort study and found UKA patients with a FJS of 91.3 (range 85.3–97.3) to be less aware of their joint replacements than TKA patients with a FJS of 54.8 (range 49.3–60.2) 1 year after implantation [55]. Therefore implant survival rates and patient satisfaction in the present study are comparable to the highest levels reported for standard, non-customized UKA implant models in literature.Hence the concept of individualizing with a CM UKA may be beneficial for treatment of medial compartmental OA of the knee. However, careful patient selection is crucial to maintaining a high level of satisfaction in UKA.This study has some limitations. The main limitation is the non-controlled design of the study. Since UKA is a well-established procedure, there are a number of studies on FJS after UKA that were published since we compared our data to literature. From a scientific point of view, a postoperative evaluation by CT would have provided greater accuracy in radiographic measurements. But since this is a clinical study involving patients, this would not have been compliant with the Ethics Committee’s requirements for patient safety. Additionally, follow-up spans a long period of time for logistic reasons. The procedure of custom-made implants and instruments is time-consuming and costly. Therefore, the recruitment period was 2 years, affecting the range of follow-up as well. Lastly, the follow-up period does not allow a conclusion on the long-term results. Further studies are needed to investigate if the durability of CM-UKA.
Conclusion
Custom-made unicondylar knee arthroplasty (CM-UKA) can provide improved clinical and functional outcome for patients with isolated knee OA of the medial compartment. This is the first study to report on PRO of CM-UKA. We found excellent results regarding patient satisfaction indicated by a reduced level of joint awareness. Further studies are needed to investigate long-term survivorship of CM-UKA implants.
Authors: Jonathan R Danoff; Rahul Goel; Ryan Sutton; Mitchell G Maltenfort; Matthew S Austin Journal: J Arthroplasty Date: 2018-02-22 Impact factor: 4.757
Authors: Michael R O'Rourke; Jeremy J Gardner; John J Callaghan; Steve S Liu; Devon D Goetz; David A Vittetoe; Patrick M Sullivan; Richard C Johnston Journal: Clin Orthop Relat Res Date: 2005-11 Impact factor: 4.176