| Literature DB >> 33224977 |
Yun'an Song1,2, Huiyan Hou1,2, Jie Bai1,2, Hongbin Gu1,2.
Abstract
BACKGROUND: Fontan operation is a palliative medical procedure performed on children with single-ventricle defects. As postoperative success of the procedure largely depends on the preload volume, it is necessary to maintain an appropriate pressure gradient between the systemic vein and the left atrium to ensure the effective volume of systemic circulation. However, there is a lack of effective indexes to evaluate fluid responsiveness in Fontan patients. Stroke volume variation (SVV) is a dynamic hemodynamic parameter based on cardiopulmonary interaction in mechanical ventilation. This study is aimed at validating the sensitivity and specificity of SVV and central venous pressure (CVP) in assessing the fluid responsiveness of Fontan patients.Entities:
Mesh:
Substances:
Year: 2020 PMID: 33224977 PMCID: PMC7669329 DOI: 10.1155/2020/2595960
Source DB: PubMed Journal: Biomed Res Int Impact factor: 3.411
Figure 1Flow chart.
Clinical data of 64 Fontan patients in responders and nonresponders.
| Parameter | Responders | Nonresponders | Total |
|---|---|---|---|
| Gender M/F ( | 30 (18/12) | 34 (19/15) | 64 (37/27) |
| Age (y) | 4.97 ± 1.14 | 4.87 ± 1.27 | 4.85 ± 1.20 |
| Height (cm) | 98.76 ± 16.54 | 97.73 ± 17.43 | 98.00 ± 16.74 |
| Weight (kg) | 15.84 ± 5.69 | 15.64 ± 5.98 | 15.65 ± 5.37 |
| Lung compliance (ml/cmH2O) | 11.3 ± 4.2 | 13.4 ± 4.4 | 12.5 ± 4.4 |
| VIS | 7.1 ± 1.7 | 6.7 ± 1.6 | 6.9 ± 1.6 |
Data is shown as (). There was no significant difference between the two groups.
Hemodynamic parameters recorded before and after fluid challenge in responders vs. nonresponders undergoing Fontan operation.
| Parameter | Before fluid challenge (BFC) | After fluid challenge (AFC) |
|
|---|---|---|---|
| HR (beats·min−1) | |||
| Responders | 117 ± 16.89 | 121.61 ± 15.93 | 0.12 |
| Nonresponders | 124.5 ± 13.64 | 122.73 ± 12.12 | 0.28 |
| | 0.13 | 0.21 | |
| SBP (mmHg) | |||
| Responders | 96.7 ± 12.32 | 102.4 ± 10.00a | 0.031a |
| Nonresponders | 95.71 ± 11.11 | 94.85 ± 13.83b | 0.075 |
| | 0.27 | 0.04b | |
| DBP (mmHg) | |||
| Responders | 48.40 ± 7.91 | 59.3 ± 7.25a | 0.03a |
| Nonresponders | 58.07 ± 7.80b | 58 ± 10.67 | 0.38 |
| | 0.04b | 0.16 | |
| MBP (mmHg) | |||
| Responders | 62.40 ± 8.23 | 75.3 ± 6.85a | 0.02a |
| Nonresponders | 72.07 ± 7.51b | 70 ± 8.05 | 0.11 |
| | 0.02b | 0.05 | |
| SVV (%) | |||
| Responders | 16.28 (14.17-19.24) | 13.68 (12.90-15.89)a | 0.02a |
| Nonresponders | 15.19 (13.78-18.09)b | 14.67 (12.88-15.89)b | 0.07 |
| | 0.03b | 0.04b | |
| SVI (ml·m−2) | |||
| Responders | 33.06 (29.40-36.34) | 37.98 (35.17-40.93) | 0.19 |
| Nonresponders | 31.66 (28.54-37.63) | 33.40 (29.57-36.97) | 0.2 |
| | 0.23 | 0.26 | |
| CI (l·min−1·m−2) | |||
| Responders | 2.46 (1.89-3.21) | 2.73 (2.19-3.42) | 0.02a |
| Nonresponders | 1.96 (1.32-2.45) | 2.06 (1.64-2.70) | 0.07 |
| | 0.24 | 0.03b | |
| CVP (mmHg) | |||
| Responders | 18.60 ± 1.83 | 20.20 ± 2.39a | 0.03a |
| Nonresponders | 18.57 ± 2.34 | 19.64 ± 3.83 | 0.16 |
| | 0.09 | 0.33 |
Data is shown as () or median (25th and 75th percentiles). HR: heart rate; SBP: systolic blood pressure; DBP: diastolic blood pressure; MBP: mean blood pressure; SVV: stroke volume variation; SVI: stroke volume index; CI: cardiac index; CVP: central venous pressure; R: responders; NR: nonresponders. aP < 0.05 compared with that before fluid challenge; bP < 0.05 compared with responders.
Figure 2Receiver operating curves of SVV to predict fluid responsiveness in Fontan patients. AUC was 0.74 (95% CI 0.54-0.94, P < 0.05), and the cutoff value was 16%, offering a sensitivity of 50% and a specificity of 91.7%.
Figure 3Receiver operating curves of CVP to predict fluid responsiveness in Fontan patients. AUC was 0.70 (95% CI 0.50–0.92, P > 0.05), and the cutoff value was 19.5 mmHg, offering a sensitivity of 58% and a specificity of 76%.